TECHNICAL DETAILS
SAFETY PRECAUTIONS
1. During Diesel delivery always wear oil resistant and always wash hands with water and soap at
the end. Always clean at once fuel stains to avoid slips and/or pollution.
2. Use particular care with the zones next to the controls.
3. When cleaning, and specially when removing dust or waste, always wear suitable clothes, if
possible use aspirators only. Always use suitable clothes or protective devices. Never place
hands or limbs under moving parts.
SYSTEM DESCRIPTION
Functional Description
The diesel transfer system are hydraulic machine tools which feed with a given capacity (volume)
of fluid in the time unit, a collecting tank, sucking the liquid from an open surface feed tank; the
allowed suction lift (geodetic suction lift Hga) is also a specific characteristic of the pump. The
system is composed by complementary equipment, operating as whole to give a complete
service:
1. Diesel pump
2. Manual dispensing nozzle
3. 2M suction hose with filter
4. 4M delivery hose
MACHINE DESCRIPTION
The wall mounted pump kit has been designed and built according to the following standards:
1. Electric requirements: EN 60204-1 and EN 60529
2. Mechanical requirements: EN 292-1 and EN 292-2; EN 55081-2, EN 55011C/A
3. Other requirements 89/392 CEE
ALLOWED AND FORBIDDEN USE
1. Diesel transfer unit has been designed and built for DIESEL TRANSFER ONLY from reservoirs,
tanks and drums.
2. It is strictly forbidden to employ it to transfer liquids of different kind as gasoline, explosives and
corrosives (or flammable), alimentary liquids.
3. The machine isn’t designed for employment in the explosive environment.
4. Operating the pump is forbidden to children and disabled person.
5. It is forbidden to employ the unit next to flammable liquids (gasoline, alcohol, etc.).
6. It is forbidden the employment in closed environments in presence of gasoline, LPG, methane
fuelled vehicles.
TRANSPORT AND UNPACKING
Due to its weight and dimensions, the unit can easily be transported by hand. Control that the
package is good conditions and verify that the unit isn’t damaged. Each failure must be noticed in
10 days from receiving the machine.
For correct unpacking carefully follow these instructions:
1. Place the case on the ground following the indications on the package.
2. Carefully open the case, remove the machine and place it on the ground or on a steady
surface.
3. Control that the machine and its accessories aren’t damaged.
Item No.
FTWM120-001
Current
AC
Voltage
120V
Power
1100W
Electrical Power
15111200
120LPM/32GPM
Flow Rate
Model of Meter
E3
Содержание FTWM120-001