Extreme operating conditions can raise the motor temperature and, consequently, cause 

the thermal protection switch to stop it.

Turn off the pump and wait for it to cool before resuming use.

The thermal protection automatically turns off when the motor is sufficiently cool.

In the priming phase the pump must blow the air initially present in the entire installation out of 

the delivery line. 

Therefore it is necessary to keep the outlet open to permit the evacuation of the air.

If an automatic type dispensing nozzle is installed at the end of the delivery line, the 

evacuation of the air will be difficult because of the automatic stopping device that 

keeps the valve closed when the line pressure is too low. It is recommended that the 

automatic dispensing nozzle be temporarily disconnected during the initial start-up 

phase.

The priming phase can last from several seconds to a few minutes, as a function of the 

characteristics of the system. If this phase is prolonged, stop the pump and verify:

• That the pump is not running completely dry; 

• That the suction tubing is not allowing air to seep in;

• That the suction filter is not clogged;

• That the suction height does not exceed 2m. (if the height exceeds 2m, fill the suction hose 

with fluid);

• That the delivery tube is allowing the evacuation of the air.

When priming has occurred, verify that the pump is operating within the anticipated range, in 

particular:

• That under conditions of maximum back pressure, the power absorption of the motor stays 

within the values shown on the identification plate;

• That the suction pressure is not greater that 0.5 bar;

• That the back pressure in the delivery line is not greater than the maximum back pressure 

foreseen for the pump.

DAILY USE

1. If using flexible tubing, attach the ends of the tubing to the tanks. In the absence of an 

appropriate slot, solidly grasp the delivery tube before beginning dispensing.

2. Before starting the pump, make sure that the delivery valve is closed (dispensing nozzle or 

line valve).

3. Turn the ON/OFF switch to ON. The by-pass valve allows functioning with the delivery 

closed only for brief periods.

4. Open the delivery valve, solidly grasping the end of the tubing.

5. Close the delivery valve to stop dispensing.

6. When dispensing is finished, turn off the pump.

Function with the delivery closed is only allowed for brief periods (2-3 minutes 

maximum). 

After use, make sure the pump is turned off.

E10

Содержание FTWM120-001

Страница 1: ...fore operating Failure to follow the safety rules and other basic safety precautions may result in serious personal injury Save these instructions in a safe place and on hand so that they can be read...

Страница 2: ...ere are certain applications for which this equipment was designed It will do the job better and more safely at the capacity for which it was intended Do not modify this equipment and do not use this...

Страница 3: ...014 1 00 A1 99 A2 99 limits and methods for measuring radio disturbance characteris tics EN55014 2 97 Electrical motor operated and thermal appliances for household and similar purposes electric tools...

Страница 4: ...extinguishers placed next to the machine Combustion of paints and plastic parts may produce toxic emissions use the normal precautions to be employed in case of fire always refer to the security super...

Страница 5: ...requirements EN 292 1 and EN 292 2 EN 55081 2 EN 55011C A 3 Other requirements 89 392 CEE ALLOWED AND FORBIDDEN USE 1 Diesel transfer unit has been designed and built for DIESEL TRANSFER ONLY from re...

Страница 6: ...The meter used in the pumping unit is calibrated at the factory Calibration is recommended upon initial use after disassembly or significant wear Meter calibration can be easily changed with the proc...

Страница 7: ...iability is limited to replacement or repair of defective material within the warranty period when returned freight prepaid to the distributor or their designated service depot 3 The warranty does not...

Страница 8: ...Description Latex Washer Nut Bolt M12 Gun base Board Meter Q ty 4 4 1 1 1 1 Part No 11 12 13 14 15 16 Description Hose Connectors Pump Inlet Outlet Nozzle Bolt Q ty 1 1 1 1 1 4 Wearing parts EXPLODED...

Страница 9: ...for continuous use under maximum back pressure Functioning under by pass conditions is only allowed for brief periods of time 2 3min utes maximum FLUIDS PERMITTED FLUIDS NOT PERMITTED PERMITTED 1 DIE...

Страница 10: ...IMENSIONS for their position and dimen sion THE MOTORS ARE NOT OF AN ANTI EXPLOSIVE TYPE Do not install them where inflammable vapours can be present 4 CONNECTING THE TUBING Before connection make sur...

Страница 11: ...quently always start up immediately 4 When the system is functioning the pump can work with pressure at the inlet as high as 0 5 bar beyond which cavitation phenomena can begin with a consequent loss...

Страница 12: ...the suction filter is not clogged That the suction height does not exceed 2m if the height exceeds 2m fill the suction hose with fluid That the delivery tube is allowing the evacuation of the air When...

Страница 13: ...Problems Low voltage in the electric power line Low level in the suction tank Foot valve blocked Filter clogged Excessive suction pressure High loss of head in the delivery circuit working with the b...

Страница 14: ...BY PASS SPRING BY PASS VALVE SCREW M6 SCREW M6 PUMP BODY O RING ROTOR BLADE Q ty 1 1 1 1 4 1 1 1 1 5 Part No 11 12 13 14 15 16 17 18 19 20 Description SCREW M5 PIN 5 PUMP COVER KEY TERMINAL BOARD DOUB...

Страница 15: ...ce at all times INSTALLATION 1 The meter can be installed in any position directly on rigid pipelines or flexible hoses or directly on pumps or tanks 2 The meter flow direction is fixed and indicated...

Страница 16: ...perly fix the plug 26 with the sealing gasket 25 USE After installation and calibration the meter is ready to work Turn the reset knob 2 clockwise if it is mounted on the left of the meter and counter...

Страница 17: ...ssembled chamber 2 Install the gaskets 16 17 properly after inspecting and lubricating them with grease 3 Make sure that when reattaching the cover to the body of the meter the nutating disk needle do...

Страница 18: ...8 19 20 21 22 23 24 25 26 27 28 Description Meter body O ring 110 72x3 53 O ring 23 47x2 62 Measuring chamber Measuring tray Measuring chamber Cylinder spring Screws 4x20 O ring 4 47x1 78 By pass adju...

Страница 19: ......

Страница 20: ...Size 145x210mm REV 03 11 22 2 09 05 30 1087 157 Macnaught Americas 813 628 5506 info macnaughtusa com Read Manual Before Use...

Отзывы: