The 

PAGING MIC VOX

 variable control adjusts

the ducking threshold for the paging mic. Rotate the
control clockwise to reduce the threshold. Rotate the
control counterclockwise to increase the threshold.

MIC/LINE INPUT

 is provided to connect a local

microphone. This is a 3-pin Phoenix-type connector
where pin 1 is ground, pin 2 is signal high (+), and
pin 3 is signal low (–).

AMBIENT MIC

 is a 3-pin Phoenix-type connector

used to connect the optional MT-3100 ambient
microphone. This microphone is used to detect the
ambient noise level in the room. The
microprocessor uses this information to adjust the
paging mic level above the ambient noise. The
ambient mic also provides an input for the optional
DSP card when it is installed.

EQ

 is a 3-band equalizer with a sweepable

midrange that only affects Inputs 1-4. 

LOW

 is a

shelving filter that provides 15 dB of boost and cut
below 80Hz. 

MID

 is a peaking filter that provides

15 dB of boost and cut at the selected frequency
between 250Hz and 8kHz. 

HIGH

 is a shelving filter

that provides 15 dB of boost and cut above 12kHz.

AMP ADDRESS

 is used to assign a unique

address to the amplifier, as well as to enable or
disable features. Switches 1-5 provide 32 separate
addresses, switch 6 determines Master/Slave
status, switch 7 enables Input 4 Priority, and switch
8 enables the optional ambient mic. Any two
amplifiers assigned to the same address can be
controlled by a single remote control when
connected together via the RS485 ports.

RS485

 is a 3-pin Phoenix-type connector in the

zone that provides an interface for the SPLinker
Sound Palette Control PC application software for
centralized computer control of up to 32 zones, as well
as communication between SP1200s and SP2400s.

When two SP1200s are linked via their RS485
connectors and assigned the same AMP ADDRESS
(switches 1-5), the front panel controls and remote
controls operate both amplifiers.

REMOTE

 is a 3-pin Phoenix-type connector for

the optional wired remote control (SP-41R), which
provides Input Select and Master Volume control.

EXPANSION IN/OUT

 consists of two parallel 25-

pin D-Sub connectors for connecting multiple
SP1200s and SP2400s together in a serial fashion.
Any of the four program sources from any SP1200
and SP2400 can be used as the source for any of
the zones in the system by assigning it to the
expansion bus with the internal Bus Assign switches.
This is a balanced bus for the four stereo input
sources. In addition, the paging mic and paging control
signal are also provided on the 

EXPANSION

 bus.

LOCAL/REMOTE

 is a set of eight DIP switches

used to select the input source for each input. Each
program input has two switches, one to select the
left signal source (odd-numbered switches) and one
to select the right signal source (even-numbered
switches). Move the switches up to select the local
program source, and down to select the remote
(external) program source from the 

EXPANSION

 bus.

PRE OUT

 is an unbalanced RCA jack that

provides a line-level signal from the preamplifier
stage of the SP1200. This provides a method for
inserting an external signal processor into the signal
chain prior to the amplifier stage. The U-shaped
jumper wire should remain installed between the

PRE OUT

 and 

AMP IN

 jacks for normal operation.

AMP IN

 is an unbalanced RCA jack that accepts

a line-level signal. See 

PRE OUT

 above.

ZONE A OUTPUT

 is a 2-pin Phoenix-type

connector that provides speaker-level signals. 

The

SP1200 is shipped with the outputs configured for
70-volt operation in U.S. versions, and 100-volt
operation in European versions.

 Internal jumpers are

provided to configure the amplifier for 8 ohm
systems as well. See page 14 for more information.

Connect the supplied AC linecord to the IEC AC

Socket. The AC line fuse is contained in the socket,
behind the cover located at the bottom of the
socket. Use replacement fuses only as indicated on
the rear panel.

PHANTOM

PAGING

GAIN +40dB

MIC/LINE INPUT A

CAUTION: 

TO REDUCE THE

RISK OF FIRE REPLACE WITH SAME

TYPE FUSE AND RATING

    115V 60Hz FUSE 115/ T4A  120 WATTS
    230V 50Hz FUSE 230/ T2A  120 WATTS

1 2 3 4

1 2 3 4 5 6 7 8

0

I

PROGRAM EQ

1 2 3 4

ZONE 

A

GAIN +40dB

PHANTOM

ON

 THE FOLLOWING ARE TRADEMARKS OR REGISTERED TRADEMARKS OF MACKIE DESIGNS INC

"MACKIE.","MACKIE INDUSTRIAL", AND THE "RUNNING MAN" FIGURE.  COPYRIGHT ©2000 ALL RIGHTS RESERVED

CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE DESIGNS INC. • WOODINVILLE • WA • MADE IN USA • FABRIQUE AU USA

PARALLEL

INPUTS

G +

CONTROL

GROUND
ALL CALL

DIRECT

R

OUTPUT

PROGRAM INPUTS

1

2

3

4

PRIORITY

L

HIGH

U

+12

–12

U

+12

–12

LOW

GAIN

+

-

HIGH 12k

FREQ

MID

LOW 80Hz

U

+15

–15

U

+15

–15

U

+15

–15

1K

3K

400

8k

250

HIGH

U

+12

–12

U

+12

–12

LOW

GAIN

+

-

+

-

AMP IN

PRE OUT

PAGING MIC

EXPANSION IN

EXPANSION OUT

AMP ADDRESS

RS485

REMOTE

AMBIENT

MIC

MIC

VOX

RISK OF ELECTRIC SHOCK

DO NOT OPEN

REPLACE WITH THE SAME TYPE FUSE AND RATING.
DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE

UTILISE UN FUSIBLE DE RECHANGE DE MÊME TYPE.
DEBRANCHER AVANT DE REMPLACER LE FUSIBLE

WARNING: 

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT 

EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. DO NOT REMOVE COVER. 
NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL.

CAUTION

AVIS:

 RISQUE DE CHOC ELECTRIQUE — NE PAS OUVRIR

SERIAL NUMBER

MANUFACTURING DATE

ZONE A

OUTPUT SUITABLE

FOR CLASS 2 WIRING

100/ 70V/8

+

1

2

3

G

+

A

G

B

1 2 3 4 5 6 7 8

LOCAL

1

2

3

4

REMOTE

1

2

3

4

SP1200

MUSIC CONTROLLER

Содержание Sound Palette SP1200

Страница 1: ...Y L HIGH U 12 12 U 12 12 LOW GAIN HIGH 12k FREQ MID LOW 80Hz U 15 15 U 15 15 U 15 15 1K 3K 400 8k 250 HIGH U 12 12 U 12 12 LOW GAIN AMP IN PRE OUT PAGING MIC EXPANSION IN EXPANSION OUT AMP ADDRESS RS4...

Страница 2: ...blades can be fully inserted to prevent blade exposure Pour pr venir les chocs lectriques ne pas utiliser cette fiche polarise avec un prolongateur un prise de courant ou une autre sortie de courant s...

Страница 3: ...fier it s designed for use in a variety of installations requiring high performance flexible features and ease of use Examples of such installations are retail stores restaurants bars and theme venues...

Страница 4: ...ccept line level signals The LOCAL REMOTE switches on the rear panel select either the local program input signal connected here or the program signal on the expansion bus See EXPANSION IN OUT on page...

Страница 5: ...d to select the input source for each input Each program input has two switches one to select the left signal source odd numbered switches and one to select the right signal source even numbered switc...

Страница 6: ...FUSE UTILISE UN FUSIBLE DE RECHANGE DE M ME TYPE DEBRANCHER AVANT DE REMPLACER LE FUSIBLE WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE DO NOT...

Страница 7: ...INPUTS 1 2 3 4 PRIORITY L HIGH U 12 12 U 12 12 LOW GAIN HIGH 12k FREQ MID LOW 80Hz U 15 15 U 15 15 U 15 15 1K 3K 400 8k 250 HIGH U 12 12 U 12 12 LOW GAIN AMP IN PRE OUT PAGING MIC EXPANSION IN EXPANSI...

Страница 8: ...A CAUTION TO REDUCE THE RISK OF FIRE REPLACE WITH SAME TYPE FUSE AND RATING 115V 60Hz FUSE 115 T4A 120 WATTS 230V 50Hz FUSE 230 T2A 120 WATTS 1 2 3 4 1 2 3 4 5 6 7 8 0 I PROGRAM EQ 1 2 3 4 ZONE A GAIN...

Страница 9: ...OTE 1 2 3 4 SP1200 MUSIC CONTROLLER PHANTOM PAGING GAIN 40dB MIC LINE INPUT A CAUTION TO REDUCE THE RISK OF FIRE REPLACE WITH SAME TYPE FUSE AND RATING 115V 60Hz FUSE 115 T4A 120 WATTS 230V 50Hz FUSE...

Страница 10: ...OTE input source over the Expansion Bus When OFF is pressed the Local Mic connected to Zone A is heard in both zones because the PRE OUT from Zone A is connected to the MIC LINE input on Zone B D Mult...

Страница 11: ...level signals 10 dBV Each of the Program Inputs is equipped with an AGC circuit instead of input trim controls These circuits automatically adjust the gain for the best signal to noise ratio accordin...

Страница 12: ...nectors DB25F The two connectors are wired in parallel so it doesn t matter which one you use as an input or output The signals on the EXPANSION IN OUT are balanced so they can be transmitted down lon...

Страница 13: ...re the power is off and the power cord disconnected before removing the top cover to gain access to the inside of the SP1200 Bus Assign There are two 8 position DIP switches on the Input Board that al...

Страница 14: ...following illustration for the locations of the jumpers On the Amplifier Board J1 Jumper pins 1 and 2 for 8 ohm operation Jumper pins 2 and 3 for 70V or 100V operation J2 Jumper pins 1 and 2 for 100V...

Страница 15: ...6 inches behind the chassis to allow proper ventilation If installing three or more SP1200s in a rack use a fan in the rack to move cool air in and warm air out of the rack s enclosure It may be neces...

Страница 16: ...e 2 band EQ LOW and HIGH to the U position This can be adjusted later if necessary SP1200 Quick Start This isn t a substitute for reading the entire instruction manual which is the only way to fully u...

Страница 17: ...he room Use the supplied Phoenix type connector to make these connections Note Move the AMP ADDRESS switch 8 UP to enable the ambient mic See page 19 for more information on Using the Ambient Mic EXPA...

Страница 18: ...al coming from the EXPANSION IN connector Each Program Input has two switches one for the left input and one for the right input Bus Assign These internal switches are used if you have two or more SP1...

Страница 19: ...directly to the paging mic input the GAIN 40 dB switch should be set in the down position for a mic level signal When the paging mic is going through an external mixer sending a line level signal to t...

Страница 20: ...few seconds and the third LED starts flashing slowly 8 Use the front panel Up Down buttons to set the lower level of the paging mic how loud it is with very quiet background noise It should be loud en...

Страница 21: ...ut directly to the distributed system The SP1200 can directly drive a distributed system s speaker line without the need for an output transformer The SP1200 can supply up to 200 watts into a 70V or 1...

Страница 22: ...time monitoring and control for up to 32 zones when used with SP2400s It provides individual program source selection and volume control for each zone Select boxes are located at the bottom of each z...

Страница 23: ...EXPANSION I O FROM EXPANSION I O FROM EXPANSION I O FROM EXPANSION I O FROM EXPANSION I O FROM EXPANSION I O FROM EXPANSION I O BUS ASSIGN TO EXPANSION I O LOCAL REMOTE LOCAL REMOTE LOCAL REMOTE LOCA...

Страница 24: ...tion 30 dB 100V position Maximum Input Level 12 volts P P 15 dBu Rise Time 5 S Slew Rate 17V S Preamplifier Section Input Levels Program Inputs 10 dBu to 10 dBu for maximum output level with internal...

Страница 25: ...ervice center 2 Pack the unit in its original packaging This is very important Mackie Industrial is not responsible for any damage that occurs during shipping due to non conventional packaging Origina...

Страница 26: ...operation Press 3 on Power Up Paging Mic Level Adjustment Press and hold the Input 3 button while powering up the SP1200 Release the Input 3 button The lowest Paging Mic level is indicated on the LED...

Страница 27: ...3 R6 D1 F1 J3 J1 J4 J2 J8 J5 J11 J14 J9 J6 J10 J7 J13 J12 D2 JP1 R5 K1 R2 C2 4A SB 250V BROWN BLUE YELLOW YELLOW RED BLACK BLACK RED YELLOW YELLOW RED BLACK RED BLACK REMOVE JUMPER FOR 230V SP1200 230...

Страница 28: ...SP1200 Music Controller Mackie Industrial 16220 Wood Red Rd NE Woodinville WA 98072 USA 888 337 7404 Outside the U S 425 487 4333 Fax 425 487 4337 www mackieindustrial com...

Отзывы: