SP1200 – 12

Signal

Pin No.

Input 1 Left (+)

Pin 1

Input 1 Left (–)

Pin 14

Input 1 Right (+)

Pin 2

Input 1 Right (–)

Pin 15

Ground

Pin 3

Input 2 Left (+)

Pin 16

Input 2 Left (–)

Pin 4

Input 2 Right (+)

Pin 17

Input 2 Right (–)

Pin 5

Ground

Pin 18

Input 3 Left (+)

Pin 6

Input 3 Left (–)

Pin 19

Input 3 Right (+)

Pin 7

Input 3 Right (–)

Pin 20

Ground

Pin 8

Input 4 Left (+)

Pin 21

Input 4 Left (–)

Pin 9

Input 4 Right (+)

Pin 22

Input 4 Right (–)

Pin 10

Paging Mic (+)

Pin 23

Paging Mic (–)

Pin 11

N/C

Pin 24

Paging Mic Control

Pin 12

–15VDC (w/J2 Installed) Pin 25
+15VDC (w/J3 Installed) Pin 13

Note:

 There is a 0.5 amp limit on

the 

±

15VDC supply.

Connecting the Remote Bus

This is a 3-pin Phoenix-type connector

specifically for connecting the optional remote
control. Use a high-quality three-conductor shielded
cable to make this connection, such as Belden
8451, 9451, or equivalent. The lower the nominal
capacitance of the wire, the more distance you can
have between the remote control and the SP1200
before suffering transmission losses.

Strip the wire back about 1/4 inch, insert the

wire as far as it will go into the appropriate hole in
the supplied Phoenix-type connector, and tighten
down the screw with a small slot-head screwdriver.
It is recommended that you use 18 to 24 gauge
wire for the remote control connections, depending
on the distance between the SP1200 and the
remote control.

The 

REMOTE

 connector is wired as follows:

Pin 1 = Ground (Shield)
Pin 2 = Data + (with +24V DC power)
Pin 3 = Data – (with +24V DC power)

Note:

 See the instructions with the remote

control for more information.

Expansion Bus Connection Chart

Connecting the Expansion Bus

These are 25-pin D-Sub connectors (DB25F). The

two connectors are wired in parallel, so it doesn’t
matter which one you use as an input or output.
The signals on the 

EXPANSION IN/OUT

 are

balanced so they can be transmitted down long
lines. The limiting factor is the capacitance of the
cable, which causes the higher frequencies to roll-
off as the capacitance increases (see chart below).
The chart indicates the lengths of cable at which
the high-frequencies are 1 dB down and 3 dB down,
using cable rated at 20pf/ft and 30pf/ft.

Use shielded twisted pairs for the 

EXPANSION

cable to ensure the best rejection of external noise
(EMI and RFI).

Maximum Feet of Cable vs. High-Frequency Roll-Off

Feet of Cable (24AWG)

0

0

100

200

300

400

500

600

700

800

900

1000

1100

1200

1300

1400

1500

1600

1700

1800

1900

2000

1.6K

3.15K

4K

5K

6.3K

8K

10K

12.5k

16K

20K

High-Frequency

 R

ol

loff

20pf/ft
30pf/ft

–1 dB point

–3 dB point

Expansion Bus Output Impedance = 220

Expansion Bus Input Impedance = 200K

For local interconnection of the Expansion Bus,

the use of standard computer cable with an overall
shield is acceptable, such as Belkin Pro Series 25-
Conductor Straight-Through Cable Assembly (Part
Number F3D111-06) or equivalent. Ensure that the
cable is wired straight-through and terminated to
DB25M connectors on each end.

Note:

 The use of ribbon cable is permissible for

these connections, only where the total length of
each cable is 12" (30cm) or less.

+15VDC (w/J3 INSTALLED)

–15VDC (w/J2 INSTALLED)

N/C

PAGING MIC (+)

INPUT 4 RIGHT (+)

INPUT 4 LEFT (+)

INPUT 3 RIGHT (–)

INPUT 3 LEFT (–)

GROUND

INPUT 2 RIGHT (+)

INPUT 2 LEFT (+)

INPUT 1 RIGHT (–)

INPUT 1 LEFT (–)

PAGING MIC CONTROL
PAGING MIC (–)
INPUT 4 RIGHT (–)
INPUT 4 LEFT (–)
GROUND
INPUT 3 RIGHT (+)
INPUT 3 LEFT (+)
INPUT 2 RIGHT (–)
INPUT 2 LEFT (–)
GROUND
INPUT 1 RIGHT (+)
INPUT 1 LEFT (+)

EXPANSION I/O

1

14

25

13

Distance Chart for SP1200 Expansion Bus Cable

Содержание Sound Palette SP1200

Страница 1: ...Y L HIGH U 12 12 U 12 12 LOW GAIN HIGH 12k FREQ MID LOW 80Hz U 15 15 U 15 15 U 15 15 1K 3K 400 8k 250 HIGH U 12 12 U 12 12 LOW GAIN AMP IN PRE OUT PAGING MIC EXPANSION IN EXPANSION OUT AMP ADDRESS RS4...

Страница 2: ...blades can be fully inserted to prevent blade exposure Pour pr venir les chocs lectriques ne pas utiliser cette fiche polarise avec un prolongateur un prise de courant ou une autre sortie de courant s...

Страница 3: ...fier it s designed for use in a variety of installations requiring high performance flexible features and ease of use Examples of such installations are retail stores restaurants bars and theme venues...

Страница 4: ...ccept line level signals The LOCAL REMOTE switches on the rear panel select either the local program input signal connected here or the program signal on the expansion bus See EXPANSION IN OUT on page...

Страница 5: ...d to select the input source for each input Each program input has two switches one to select the left signal source odd numbered switches and one to select the right signal source even numbered switc...

Страница 6: ...FUSE UTILISE UN FUSIBLE DE RECHANGE DE M ME TYPE DEBRANCHER AVANT DE REMPLACER LE FUSIBLE WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE DO NOT...

Страница 7: ...INPUTS 1 2 3 4 PRIORITY L HIGH U 12 12 U 12 12 LOW GAIN HIGH 12k FREQ MID LOW 80Hz U 15 15 U 15 15 U 15 15 1K 3K 400 8k 250 HIGH U 12 12 U 12 12 LOW GAIN AMP IN PRE OUT PAGING MIC EXPANSION IN EXPANSI...

Страница 8: ...A CAUTION TO REDUCE THE RISK OF FIRE REPLACE WITH SAME TYPE FUSE AND RATING 115V 60Hz FUSE 115 T4A 120 WATTS 230V 50Hz FUSE 230 T2A 120 WATTS 1 2 3 4 1 2 3 4 5 6 7 8 0 I PROGRAM EQ 1 2 3 4 ZONE A GAIN...

Страница 9: ...OTE 1 2 3 4 SP1200 MUSIC CONTROLLER PHANTOM PAGING GAIN 40dB MIC LINE INPUT A CAUTION TO REDUCE THE RISK OF FIRE REPLACE WITH SAME TYPE FUSE AND RATING 115V 60Hz FUSE 115 T4A 120 WATTS 230V 50Hz FUSE...

Страница 10: ...OTE input source over the Expansion Bus When OFF is pressed the Local Mic connected to Zone A is heard in both zones because the PRE OUT from Zone A is connected to the MIC LINE input on Zone B D Mult...

Страница 11: ...level signals 10 dBV Each of the Program Inputs is equipped with an AGC circuit instead of input trim controls These circuits automatically adjust the gain for the best signal to noise ratio accordin...

Страница 12: ...nectors DB25F The two connectors are wired in parallel so it doesn t matter which one you use as an input or output The signals on the EXPANSION IN OUT are balanced so they can be transmitted down lon...

Страница 13: ...re the power is off and the power cord disconnected before removing the top cover to gain access to the inside of the SP1200 Bus Assign There are two 8 position DIP switches on the Input Board that al...

Страница 14: ...following illustration for the locations of the jumpers On the Amplifier Board J1 Jumper pins 1 and 2 for 8 ohm operation Jumper pins 2 and 3 for 70V or 100V operation J2 Jumper pins 1 and 2 for 100V...

Страница 15: ...6 inches behind the chassis to allow proper ventilation If installing three or more SP1200s in a rack use a fan in the rack to move cool air in and warm air out of the rack s enclosure It may be neces...

Страница 16: ...e 2 band EQ LOW and HIGH to the U position This can be adjusted later if necessary SP1200 Quick Start This isn t a substitute for reading the entire instruction manual which is the only way to fully u...

Страница 17: ...he room Use the supplied Phoenix type connector to make these connections Note Move the AMP ADDRESS switch 8 UP to enable the ambient mic See page 19 for more information on Using the Ambient Mic EXPA...

Страница 18: ...al coming from the EXPANSION IN connector Each Program Input has two switches one for the left input and one for the right input Bus Assign These internal switches are used if you have two or more SP1...

Страница 19: ...directly to the paging mic input the GAIN 40 dB switch should be set in the down position for a mic level signal When the paging mic is going through an external mixer sending a line level signal to t...

Страница 20: ...few seconds and the third LED starts flashing slowly 8 Use the front panel Up Down buttons to set the lower level of the paging mic how loud it is with very quiet background noise It should be loud en...

Страница 21: ...ut directly to the distributed system The SP1200 can directly drive a distributed system s speaker line without the need for an output transformer The SP1200 can supply up to 200 watts into a 70V or 1...

Страница 22: ...time monitoring and control for up to 32 zones when used with SP2400s It provides individual program source selection and volume control for each zone Select boxes are located at the bottom of each z...

Страница 23: ...EXPANSION I O FROM EXPANSION I O FROM EXPANSION I O FROM EXPANSION I O FROM EXPANSION I O FROM EXPANSION I O FROM EXPANSION I O BUS ASSIGN TO EXPANSION I O LOCAL REMOTE LOCAL REMOTE LOCAL REMOTE LOCA...

Страница 24: ...tion 30 dB 100V position Maximum Input Level 12 volts P P 15 dBu Rise Time 5 S Slew Rate 17V S Preamplifier Section Input Levels Program Inputs 10 dBu to 10 dBu for maximum output level with internal...

Страница 25: ...ervice center 2 Pack the unit in its original packaging This is very important Mackie Industrial is not responsible for any damage that occurs during shipping due to non conventional packaging Origina...

Страница 26: ...operation Press 3 on Power Up Paging Mic Level Adjustment Press and hold the Input 3 button while powering up the SP1200 Release the Input 3 button The lowest Paging Mic level is indicated on the LED...

Страница 27: ...3 R6 D1 F1 J3 J1 J4 J2 J8 J5 J11 J14 J9 J6 J10 J7 J13 J12 D2 JP1 R5 K1 R2 C2 4A SB 250V BROWN BLUE YELLOW YELLOW RED BLACK BLACK RED YELLOW YELLOW RED BLACK RED BLACK REMOVE JUMPER FOR 230V SP1200 230...

Страница 28: ...SP1200 Music Controller Mackie Industrial 16220 Wood Red Rd NE Woodinville WA 98072 USA 888 337 7404 Outside the U S 425 487 4333 Fax 425 487 4337 www mackieindustrial com...

Отзывы: