Mackie Sound Palette SP1200 Скачать руководство пользователя страница 18

SP1200 – 18

Using Inputs 1-4

Connect the program sources to Inputs 1-4.

These could include a CD player, tape deck, tuner,
satellite feed, TV audio, jukebox, or an audio feed
from a live band. All four program inputs use
unbalanced RCA connectors and accept stereo line-
level signals.

Note:

 The Input Select buttons are labeled 1

through 4 on the front panel. The spaces below the
buttons are sized to accept 1/4" labels from the
Brother P-Touch Electronic Labeling System.
Professional-looking labels can be made to clearly
identify the program source connected to each
input (visit 

www.brother.com

).

There are no individual volume controls for

Inputs 1-4. The SP1200 automatically adjusts the
volume for each input using an AGC circuit
(Automatic Gain Control). This provides the best
signal-to-noise ratio and insures that the volume
remains the same when you switch from one
source to another.

Only one Input source can be selected at a time.

When switching from one source to another, the
previous source fades out while the new source
fades in (digital crossfade), rather than abruptly
switching between the two.

Input 1 and the DIRECT OUTPUT

Input 1 provides a direct line-level output that

can be used for music-on-hold or other external
applications. Connect a continuous music source
(i.e., satellite feed, prerecorded background music,
multi-disc CD player) to Input 1 and connect the

DIRECT OUTPUT

 jacks to the external destination.

Input 4 Priority

Normally, the four program inputs are non-

priority inputs. However, if there is a jukebox or
other priority program source in the system,
Program Priority can be activated on Input 4 by
setting 

AMP ADDRESS

 switch #7 UP. When a

signal appears at Input 4, it overrides the other
three inputs. When the signal stops, the SP1200
switches back to the previously selected input
source, fading it in smoothly. 

Local or Remote

These switches are used to select the input

source for each of the four Program Inputs. Leave
the switches up to select the local input source
connected to the 

PROGRAM INPUT

 connector.

Move the switches down to select the remote
signal coming from the 

EXPANSION IN

 connector.

Each Program Input has two switches, one for the
left input and one for the right input.

Bus Assign

These internal switches are used if you have two

or more SP1200s connected together in a system
using the 

EXPANSION IN/OUT

 connectors. Each of

the four program inputs can be individually assigned
to the 

EXPANSION

 balanced bus. There are four

switches associated with each Program Input source
(see the Bus Assign Switch chart on page 13).

CAUTION:

 When using multiple SP1200s

that use the expansion bus, these switch
settings 

must

 be unique to each unit or

you can damage your SP1200(s). 

Never

 assign

more than one program source to the same channel
on the Expansion Bus.

EXPANSION IN/OUT

These two 25-pin D-Sub connectors are used to

connect two or more SP1200s together so they can
share program sources. This is a true balanced bus
and transmits the left and right signal from each of
the four inputs over balanced lines. Refer to the
“Connections” section on page 11 for information
on wiring these connectors.

These connections allow a common program

source to be available to all the SP1200s in a
system. For example, prerecorded music that is
used for music-on-hold can also serve as background
music for an entire office building by setting the
internal bus assign switches for Input 1 to the up
position on the first SP1200. The music is then
available to Input 1 on all the SP1200s connected
via the 

EXPANSION IN/OUT

 connectors when their

LOCAL/REMOTE

 switches are set to the 

REMOTE

position (down).

Note:

 Switching the 

LOCAL/REMOTE

 switch to

REMOTE

 doesn't disconnect the local input. If a

different program source is connected locally to
Input 1 on one of the SP1200s in the above
example, both the common program source (the
remote prerecorded music) and the local program
source will be combined on Input 1 and can be
played simultaneously. Typically, a local program
source would not be connected to an Input which
has 

REMOTE

 selected as the source.

Using the 3-Band EQ

This equalizer is applied to the selected program

source from Inputs 1-4, whether it is a local source
or remote source (via the 

EXPANSION IN/OUT

 bus).

This equalizer does not affect the paging mic or

the local 

MIC/LINE INPUTS

, which each have their

own 2-band EQ controls.

Содержание Sound Palette SP1200

Страница 1: ...Y L HIGH U 12 12 U 12 12 LOW GAIN HIGH 12k FREQ MID LOW 80Hz U 15 15 U 15 15 U 15 15 1K 3K 400 8k 250 HIGH U 12 12 U 12 12 LOW GAIN AMP IN PRE OUT PAGING MIC EXPANSION IN EXPANSION OUT AMP ADDRESS RS4...

Страница 2: ...blades can be fully inserted to prevent blade exposure Pour pr venir les chocs lectriques ne pas utiliser cette fiche polarise avec un prolongateur un prise de courant ou une autre sortie de courant s...

Страница 3: ...fier it s designed for use in a variety of installations requiring high performance flexible features and ease of use Examples of such installations are retail stores restaurants bars and theme venues...

Страница 4: ...ccept line level signals The LOCAL REMOTE switches on the rear panel select either the local program input signal connected here or the program signal on the expansion bus See EXPANSION IN OUT on page...

Страница 5: ...d to select the input source for each input Each program input has two switches one to select the left signal source odd numbered switches and one to select the right signal source even numbered switc...

Страница 6: ...FUSE UTILISE UN FUSIBLE DE RECHANGE DE M ME TYPE DEBRANCHER AVANT DE REMPLACER LE FUSIBLE WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE DO NOT...

Страница 7: ...INPUTS 1 2 3 4 PRIORITY L HIGH U 12 12 U 12 12 LOW GAIN HIGH 12k FREQ MID LOW 80Hz U 15 15 U 15 15 U 15 15 1K 3K 400 8k 250 HIGH U 12 12 U 12 12 LOW GAIN AMP IN PRE OUT PAGING MIC EXPANSION IN EXPANSI...

Страница 8: ...A CAUTION TO REDUCE THE RISK OF FIRE REPLACE WITH SAME TYPE FUSE AND RATING 115V 60Hz FUSE 115 T4A 120 WATTS 230V 50Hz FUSE 230 T2A 120 WATTS 1 2 3 4 1 2 3 4 5 6 7 8 0 I PROGRAM EQ 1 2 3 4 ZONE A GAIN...

Страница 9: ...OTE 1 2 3 4 SP1200 MUSIC CONTROLLER PHANTOM PAGING GAIN 40dB MIC LINE INPUT A CAUTION TO REDUCE THE RISK OF FIRE REPLACE WITH SAME TYPE FUSE AND RATING 115V 60Hz FUSE 115 T4A 120 WATTS 230V 50Hz FUSE...

Страница 10: ...OTE input source over the Expansion Bus When OFF is pressed the Local Mic connected to Zone A is heard in both zones because the PRE OUT from Zone A is connected to the MIC LINE input on Zone B D Mult...

Страница 11: ...level signals 10 dBV Each of the Program Inputs is equipped with an AGC circuit instead of input trim controls These circuits automatically adjust the gain for the best signal to noise ratio accordin...

Страница 12: ...nectors DB25F The two connectors are wired in parallel so it doesn t matter which one you use as an input or output The signals on the EXPANSION IN OUT are balanced so they can be transmitted down lon...

Страница 13: ...re the power is off and the power cord disconnected before removing the top cover to gain access to the inside of the SP1200 Bus Assign There are two 8 position DIP switches on the Input Board that al...

Страница 14: ...following illustration for the locations of the jumpers On the Amplifier Board J1 Jumper pins 1 and 2 for 8 ohm operation Jumper pins 2 and 3 for 70V or 100V operation J2 Jumper pins 1 and 2 for 100V...

Страница 15: ...6 inches behind the chassis to allow proper ventilation If installing three or more SP1200s in a rack use a fan in the rack to move cool air in and warm air out of the rack s enclosure It may be neces...

Страница 16: ...e 2 band EQ LOW and HIGH to the U position This can be adjusted later if necessary SP1200 Quick Start This isn t a substitute for reading the entire instruction manual which is the only way to fully u...

Страница 17: ...he room Use the supplied Phoenix type connector to make these connections Note Move the AMP ADDRESS switch 8 UP to enable the ambient mic See page 19 for more information on Using the Ambient Mic EXPA...

Страница 18: ...al coming from the EXPANSION IN connector Each Program Input has two switches one for the left input and one for the right input Bus Assign These internal switches are used if you have two or more SP1...

Страница 19: ...directly to the paging mic input the GAIN 40 dB switch should be set in the down position for a mic level signal When the paging mic is going through an external mixer sending a line level signal to t...

Страница 20: ...few seconds and the third LED starts flashing slowly 8 Use the front panel Up Down buttons to set the lower level of the paging mic how loud it is with very quiet background noise It should be loud en...

Страница 21: ...ut directly to the distributed system The SP1200 can directly drive a distributed system s speaker line without the need for an output transformer The SP1200 can supply up to 200 watts into a 70V or 1...

Страница 22: ...time monitoring and control for up to 32 zones when used with SP2400s It provides individual program source selection and volume control for each zone Select boxes are located at the bottom of each z...

Страница 23: ...EXPANSION I O FROM EXPANSION I O FROM EXPANSION I O FROM EXPANSION I O FROM EXPANSION I O FROM EXPANSION I O FROM EXPANSION I O BUS ASSIGN TO EXPANSION I O LOCAL REMOTE LOCAL REMOTE LOCAL REMOTE LOCA...

Страница 24: ...tion 30 dB 100V position Maximum Input Level 12 volts P P 15 dBu Rise Time 5 S Slew Rate 17V S Preamplifier Section Input Levels Program Inputs 10 dBu to 10 dBu for maximum output level with internal...

Страница 25: ...ervice center 2 Pack the unit in its original packaging This is very important Mackie Industrial is not responsible for any damage that occurs during shipping due to non conventional packaging Origina...

Страница 26: ...operation Press 3 on Power Up Paging Mic Level Adjustment Press and hold the Input 3 button while powering up the SP1200 Release the Input 3 button The lowest Paging Mic level is indicated on the LED...

Страница 27: ...3 R6 D1 F1 J3 J1 J4 J2 J8 J5 J11 J14 J9 J6 J10 J7 J13 J12 D2 JP1 R5 K1 R2 C2 4A SB 250V BROWN BLUE YELLOW YELLOW RED BLACK BLACK RED YELLOW YELLOW RED BLACK RED BLACK REMOVE JUMPER FOR 230V SP1200 230...

Страница 28: ...SP1200 Music Controller Mackie Industrial 16220 Wood Red Rd NE Woodinville WA 98072 USA 888 337 7404 Outside the U S 425 487 4333 Fax 425 487 4337 www mackieindustrial com...

Отзывы: