I/O Cards & Cables

I/O cards are available in four different flavors and can be mixed and matched in
any combination:

AIO•8

•   Each AIO•8 provides 8 analog line-level inputs and outputs on two 25-pin

D-subminiature (DB25) connectors. These connectors are pin-for-pin
compatible with the analog (not TDIF) DB25 connectors found on the
TASCAM DTRS recorders. DB25 cables that break out to XLR or 1/4" TRS
connectors for mating with your console are readily available.

DIO•8

•   Each DIO•8 provides 8 digital inputs and outputs in two formats:

1.  TASCAM Digital Interface (TDIF) provides 8 input and output channels

of digital audio on a single DB25 connector. It requires a TASCAM
PW-88D or equivalent TDIF-compatible cable.

2.  ADAT Optical provides 8 channels of digital audio on fiber-optic cable.

Two optical cables are required for each card, one for inputs, the other
for outputs. Both cables must connect to the same device, creating a
closed loop.

3.  The DIO•8 also provides a TDIF word clock sync output for use with

older TASCAM equipment.

OPT• 8

•   The OPT•8 is a low-cost, ADAT Optical-only version of the DIO•8 card.

The previous ADAT information also applies to this card.

PDI• 8

•   Each PDI•8 carries four stereo pairs (eight channels) of digital input and

output on a single DB25 connector. This card supports the AES/EBU
(IEC-958 Type 1) digital interfacing standard carrying two channels of
digital audio on a single balanced cable. The PDI•8 can also be configured
for the consumer (IEC-958 Type 2, or S/PDIF) data format if required.
DB25 cables that break out to XLR connectors, and double-ended DB25 to
DB25 AES/EBU cables for mating with your console, are readily available.

    The PDI•8 is the only Mackie I/O card that currently supports 88.2 or 96

kHz operation. At these Sample Rates the PDI•8 card runs in “double-
wide” (dual-wire) mode. In double-wide mode, the PDI•8 carries four mono
channels of digital I/O by transmitting two consecutive 88.2/96k samples
of the same channel on a single conductor.

APOGEE

DIGITAL I/O

SYNC

IN

OUT

TDIF

ADAT OPTICAL

INPUT

O

UTPUT

ANALOG I/O

AIO•8

DIO•8

PDI•8

AES/EBU I/O

PDI• 8

OPT•8

Note: Different manufacturers use different wiring standards for DB25 in-
terface cables (both analog and digital) that otherwise look the same. Make
sure the cable you are using is the correct one. See Appendix A for a list of
compatible I/O card cables for the HDR24/96.

Содержание HDR 24

Страница 1: ...24 TRACK 24 BIT DIGITAL AUDIO HARD DISK RECORDER AND EDITOR Operation Guide HDR 24 HDR 24 HDR 24 HDR 24 HDR 24 96...

Страница 2: ...and complies with the following standards and directives as set forth by the European Union EN 55022 Radiated and Conducted Emissions EN 61000 4 2 Electrostatic Discharge Immunity EN 61000 4 3 RF Elec...

Страница 3: ...19 Hookups 21 Analog Hookup AIO 8 21 TDIF Hookup DIO 8 23 ADAT Optical Hookup DIO 8 or OPT 8 25 AES EBU Hookup PDI 8 28 HDR24 96 Operation 30 Opening Projects 30 Basic Transport Operations 32 Time Dis...

Страница 4: ...ipping so that it won t end up more broken than when you sent it How To Use This Guide Welcome to the cutting edge of affordable multitrack recording and editing We know you re feeling eager but pleas...

Страница 5: ...escription of how to perform an action from the front panel This icon identifies in depth explanations of features and practical tips Though not required reading they do offer some choice tidbits of k...

Страница 6: ...port via the built in FTP server Offers two optional remote control devices the compact Remote 24 for smaller project studios and the full featured Remote 48 for controlling up to 48 tracks on two HD...

Страница 7: ...ection describes how to install the I O cards and how to connect the HDR24 96 to your console Before you begin you should choose a location for your HDR24 96 considering the following If you re not us...

Страница 8: ...ly version of the DIO 8 card The previous ADAT information also applies to this card PDI 8 Each PDI 8 carries four stereo pairs eight channels of digital input and output on a single DB25 connector Th...

Страница 9: ...at the component side faces left 5 Line up the card so that the top and bottom edges slide smoothly into the white card guides Push the card all the way in until its faceplate is flush with the back p...

Страница 10: ...ous clocks Whenever time code positional synchronization is used all the devices in a system both analog and digital must be synchronized to a common timing speed reference This is often achieved by d...

Страница 11: ...receiving device s With the HDR24 96 configured as a slave connect the word clock out of the master ADAT Optical device to Word Clock In on the HDR24 96 AES EBU PDI 8 With the HDR24 96 as a master set...

Страница 12: ...te Note Note Mackie Media are hard drives and as we all know hard drives involve some pretty intricate technology So don t shake the little darlin and if a tray has just come in from a freezing car or...

Страница 13: ...rtical scan rate and for the best picture should have at least a 17 screen 2 Connect a two button PS 2 compatible mouse to the Mouse port 3 Connect a PC style keyboard to the Keyboard port If your key...

Страница 14: ...uently used functions like Play Stop New Cue Solo and Next Cue connect the cable of a momentary normally open footswitch to the FOOT SWITCH 1 4 TS jack on the rear panel of the HDR24 96 the Remote 24...

Страница 15: ...you the current input settings for each of the three I O cards 3 Press the Select button corresponding to each DIO 8 card and toggle the selection between ADAT and TDIF 4 Press the Page Left button t...

Страница 16: ...desired output format Or select the TDIF ADAT or ADAT TDIF option to convert between formats bypassing the HDR24 96 tape signal path entirely 4 Click the arrow in the top right corner of the dialog or...

Страница 17: ...an eight settings you have four one for each pair of channels To set the PDI 8 card options 1 Press DIGI I O to enter the Digital I O Card Setup menu 2 Select Rate Convert The Sample Rate Convert scre...

Страница 18: ...n leave the boxes unchecked for no sample rate conversion default 3 Then select Pro default or Consumer from the pulldown menus associated with the desired output s Click the arrow in the top right co...

Отзывы: