![background image](http://html1.mh-extra.com/html/mach/m-flex-12/m-flex-12_user-manual_685964016.webp)
16
Troubleshooting
T
ROUBLESHOOTING
A
Problem
Remedy
No sound.
Make sure that all XLR cables are wired according to the
AES standards:
Hot (+) - Pin2
Cold (-) - Pin3
Shield (ground) - Pin1
Make sure that the signal is strong enough. A weak signal
may result in the unit shutting down if the stand-by function
is enabled.
No sound when microphone is
connected to mic. input.
The microphone requires phantom power. Switch to a
dynamic microphone.
Distorted sound, but peak indicator
does not come on.
Mixer or other sources is overdriven/clipping. Turn down the
signal from the source.
Low input signal.
Ensure that the input cables are balanced.
Feedback when microphone is turned
up.
Microphones have very different characteristics depending
on which application they are designed for. Make sure that
the microphone is a vocal microphone with a Cardioid
(unidirectional) characteristic. Shure offer good help to
choosing the right microphone. Check:
http://www.shure.com/microphones/microphone_help.asp
Turn Microphone away from the speaker.
Reduce bass and treble EQ
Table 1: Troubleshooting