12
Stand-by function
S
TAND
-
BY
FUNCTION
4
The active M
•
Flex models feature a stand-by function. When this function is
enabled and no input signal has been sensed for one hour (or the signal is at a very
low level), the amplifier automatically shuts down. When signal is restored to the
speaker, the amplifier will automatically be turned on.
The stand-by function is disabled by default in models after and including:
• M
•
Flex 12 (115 volt) models - serial number 701124
• M
•
Flex 12 (230 volt) models - serial number 701316
• M
•
Flex 15 (115 volt) models - serial number 701555
• M
•
Flex 15 (230 volt) models - serial number 701694
Note that the serial number label can be found on the back of the speaker unit. The
stand-by function is enabled by default in all models with serial numbers prior to
these.
E N A B L I N G O R D I S A B L I N G T H E S T A N D -
B Y F U N C T I O N
The stand-by function is enabled by removing a jumper from a printed circuit board
(PCB) inside the fixture.
To access the PCB:
1 Using a Torx 20 screwdriver, remove the 8 screws that hold the woofer cover in place.