33
ALARM NO
:
01
ACTION
:
NONE
CONTACT
:
N/O
PRESET
:
001
AUTO SCAN
:
001
CRUISE
:
001
RELAY OUT
:
OFFS
RESET DELAY
:
3S
SAVE
BACK
EXIT
•
PRESET: The speed dome will go to the selected preset at the specified time if you
select the time task as preset. The value ranges from 1 to 80.
•
SCAN: The speed dome will go to the selected scan at the specified time if you select the
time task as scan. The value ranges from 1 to 5.
•
TOUR: The speed dome will go to the selected preset at the specified time if you select
the time task as tour. The value ranges from 1 to 8.
•
PATTERN: The speed dome will go to the selected pattern at the specified time if you
select the time task as pattern. The value ranges from 1 to 5.
•
SAVE: After you completed the above setup, you need to move the cursor here and then
click confirm button to save current time setup.
•
BACK: Go back to the previous menu.
•
EXIT: Log out the system menu.
4.4.5 Alarm
Setup
Move the cursor to highlight ALARM SETTING button and then click confirm button.
z
ALARM NO: Here is to set alarm input. Alarm input value ranges from 1 to 7. Please use the
left/right button on the keyboard or in the speed dome terminal menu to set.
z
ACTION: Action on alarm function. It includes NONE/PRESET/AUTO SCAN/TOURING
functions. Please use the left/right button on the keyboard or in the speed dome terminal
menu to set.
z
CONTACT
:
You can set system activation operation once alarm occurred. There are two
alarm signal mode: normal open (N/O) and normal closed (N/C). Please use the left/right
button on the keyboard or in the speed dome terminal menu to set.
z
PRESET
NO
:
Please use the left/right button on the keyboard or in the speed dome
terminal menu to set. The camera will turn to the specified preset to monitor after alarm
occurs.
z
AUTO
SCAN
:
Please use the left/right button on the keyboard or in the speed dome
terminal menu to set. The camera will begin auto scan after alarm occurs.
z
CRUISE
:
Please use the left/right button on the keyboard or in the speed dome terminal
menu to set. The camera will begin auto cruise when alarm occurs.
z
RELAY OUT: Here is to set relay alarm mode and reset time. There are several options:
off/1
→
5S/2
→
5S/1&2
→
5S.