a. P
OwerinG
uP
the
d
OOr
/w
indOw
S
enSOrS
• Remove the battery cover; insert new batteries noting the polarity
as shown in the diagram below and replace the cover.
(Requires 2 x AAA batteries)
• Low battery indication: If the batteries need to be replaced,
the RED LED on the transmitter will flash slowly.
B. i
nStallinG
the
d
OOr
/w
indOw
S
enSOrS
• Mount the transmitter on a fixed surface such as a door
or a window frame.
• Mount the magnet on a movable surface such as a door or a window.
• Ensure the >|< marks on the sides of the transmitter and magnet match
up as shown in the diagram.
• The transmitter and the magnet must be no more than 5mm apart
c. m
OuntinG
with
the
d
OuBle
-S
ided
a
dheSive
P
ad
• Ensure the mounting surface is clean.
• Peel back one layer of the protective film and attach it to the transmitter.
• Peel back the remaining layer of protective film and press the transmitter firmly in place against
the mounting surface until firmly attached.
• Repeat to attach the magnet.
4.2.2 i
nStallinG
the
m
OtiOn
S
enSOr
(optional accessory)
The Motion Sensor is designed to sense movement in a given area.
Note: It is best if pets are not allowed onto higher surfaces so that the
sensors are not triggered unnecessarily (no more than 3 feet high).
a. P
OwerinG
uP
the
m
OtiOn
S
enSOr
• Remove the battery cover, insert and connect a 9V battery as shown in
diagram below and replace the cover. (Requires 1 x 9V battery)
• Low battery indication: If the batteries need to be replaced, the RED LED will flash
(not including entry/exit delay flashing).
B. i
nStallinG
the
m
OtiOn
S
enSOr
First, determine the location of the Motion Sensor.
*Note:
The Sensor should be placed:
• In the most vulnerable rooms or near key entry points.
• On a solid surface between 6 ft to 8 ft (1.8m to 2.4m) from the floor.
• Away from extreme temperature sources (radiators, ovens, stoves etc.)
• Away from direct sunlight.
• Indoors only and not behind partitions
• Where better RF performance can be achieved (if necessary)
c. S
enSOr
S
enSitivity
IMPORTANT!
The Motion Sensor is designed with a power saving program and will remain inactive for 3 minutes
after each detection. Please bear this in mind during system set up.
The sensitivity of the Motion sensor is adjustable and can be changed by setting the connector, found
in the battery compartment, on either the ‘High’, ‘Middle’ or ‘Low’ position. When the sensitivity is set
to “Low”, more movement is required to trigger the sensor. It is recommended to set the sensitivity
to “Low” and perform a “Walk Test” (Described in part D). If the walk test result is satisfactory, the
sensitivity does not require further adjustment. If the walk test result shows the sensitivity is too low,
then the sensitivity can be set to “Middle” or “High” as required. It is recommended that a walk test be
conducted after each change in sensitivity setting.