214658
130
Revision A
Calibrating Auto Header Height Control (New Holland CR Series)
NOTE:
Changes may have been made to the combine controls or display since this document was published. Refer to the
combine operator
’
s manual for updates.
CAUTION
Check to be sure all bystanders have cleared the area.
Check the following conditions before starting the header calibration procedure:
•
The header is attached to the combine.
•
The combine is on level ground, with the header level to the ground.
•
The engine is running.
•
The combine is
NOT
moving.
•
No faults have been received from Header Height Controller (HHC) module.
•
Header/feeder is disengaged.
•
Lateral float buttons are
NOT
pressed.
•
ESC key is
NOT
pressed.
To calibrate the AHHC, follow these steps:
1016108
A
Figure 6.116: New Holland Combine Display
1.
Select CALIBRATIONS (A) on the main page. The
CALIBRATION page displays.