CAUTION
:
Improper profile setting may damage the batteries. To change setting remove cover
and follow instructions in charger.
7. When batteries are fully charged, only the Green LED "Charge Complete"
should be illuminated.
!
WARNING
-
Do not disconnect the DC output cord from the battery receptacle when the charger
is on. The resulting arcing and burning of the plug and receptacle could cause the batteries to
explode. If the charger must be stopped, first press the stop button, if provided, or disconnect the
AC power supply cord from its outlet, then disconnect the charger DC output plug from the battery
receptacle.
LED INDICATORS
Normal Charge Sequence-
1-
During the initial constant current stage, both the Yellow LED "Charger On" and the Red LED
"Incomplete" will illuminate. A flashing Red LED "Incomplete" prior to the Yellow LED "80% Charge"
coming on indicates a (S) Sealed Valve Regulated profile has been selected. NOTE - Early models did
not incorporate this flashing LED feature.
2-
When battery voltages reach 2.35 to 2.38 volts/cell, the Yellow LED "80% Charge" will illuminate.
3-
When a charge cycle is terminated both the Yellow LED "80% Charge" and the Yellow LED "Charger
On" will turn off. The Green LED "Complete" will then illuminate.
GREEN
"CHARGE COMPLETE"
YELLOW
"80% CHARGE"
RED
"INCOMPLETE" flashes in SVR mode
YELLOW
"CHARGER ON"
RED
"ABNORMAL CYCLE"
Abnormal Charge Sequence
1-
If a charge cycle does not finish in 16 to 20 hours, only the Red LED "Abnormal Cycle" lights up.
All other LED's turn off.