that the elements used in the high pressure packing could to hurt the operator if not handled
with care. These packings must be digested therefore and not left to the course of children or of
irresponsible persons. The same is worth for the objects used in the removal of the unpacking
pack (knives, scissors.). For tied up demands to unpacking and to the transport, some
components are supplied not installed; proceed therefore to the installation according to the
instructions of the manual.
7.
Installation
7.1.
Control carefully that the environment for the installation of the high pressure cleaner
considering all the foreseen and unforeseen possibilities. The machine is equipped with insane
wheels, therefore it is unadvisable to position, without precautions, on tilted surfaces. Do never
tilt the high pressure cleaner to more than 20° when the tanks are full.
8.
Connection to the electricity supply
8.1.
The high pressure cleaner can be connected to alternating single phase (230V) or three phase
(400 V) with frequency 50hz. For the three phase models, the high pressure cleaner is normally
supplied connected to 400 V, although can be in demand connected to other connections (for
instance 230v).
8.2.
For the maximum absorption of the electricity, compare the underlying chart.
8.3.
Verify that the electric net, to which the machine is connected with the electric cable, has the
appropriate characteristics.
8.4.
The high pressure cleaner is endowed with a magnetothermic switch that interrupts the power
supply in the case the absorption of the supply overcomes the value of the setting; for the
location of the switch, take a look to the electric plan attached to the machine.
8.5.
The client buyer is kept to subsequently protect the line of the power supply by installing a
lifesaver with a load not exceeding 30A.
8.6.
The cable is supplied without plug for the connection to the net: this must be installed by the
buyer, which will verify that:
8.1.1.
The plug is proper for the data of the voltage and the tension above described;
8.1.2.
The plug is conforming to the norms in force in the nation of installation and use and that
in any event it is earthed.
8.1.3.
The connection cable and plug connection is waterproof.
8.1.4.
If a cable with extension is used, this must have a minimum section of 2,5 mmqs if the
cable is long up to 20 mt, or of 4,0 mmqs if the cable has a superior length than 20 mt.
The flying thorns and plugs are forbidden: to use some cablereels.
8.1.5.
If the cable of the connection is damaged, this must be immediately replaced with a
proper cable: such operation must be performed by specific and authorized personnel.
KW
Motor absorption A
Thermic 230v A
Thermic 400v A
KW 2,2
13
14
0
KW 3
8
14
9
KW 4
10
16
11
KW 5,5
13
22
14
KW 7,5
15,6
28
20