Ensure that the installation bracket of the outdoor appliance is not 
damaged due to prolonged exposure. If bracket is damaged, there is 
concern of damage due to falling of unit.

Appearance may be deteriorated due to change of product color or 
scratching of its surface.

Do not use strong detergent such as wax or thinner but use a soft cloth.

Do not place heavy object on the power cord and ensure that the cord
is not compressed. There is danger of fire or electric shock.
Do not drink water drained from air conditioner.
It contains contaminants and could make you sick.
Use caution when unpacking and installing. Sharp edges could cause 
injury.
If water enters the unit, turn the unit off at the power outlet and switch 
off the circuit breaker. Isolate supply by taking the power-plug out or 
disconnect the power supply to the unit, and contact a qualified service 
technician.

This appliance can be used by children aged from 8 years and 
above and persons with reduced physical, sensory or mental 
capabilities or lack of experience and knowledge if they have been 
given supervision or instruction concerning use of the appliance in 
a safe way and understand the hazards involved. Children shall not 
play with the appliance. Cleaning and user maintenance shall not 
be made by children without supervision. (be applicable for the 
European Countries )
This appliance is not intended for use by persons (including 
children) with reduced physical ,sensory or mental capabilities or 
lack of experience and knowledge, unless they have been given 
supervision or instruction concerning use of the appliance by a 
person responsible for their safety. (be applicable for other 
countries except the European Countries )
Children should be supervised to ensure that they do not play with 
the appliance. 
If the supply cord is damaged, it must be replaced by the 
manufacturer, its service agent or similarly qualified persons in 
order to avoid a hazard.
The appliance shall be installed in accordance with national wiring 
regulations.

Содержание MEV07VQ

Страница 1: ...please read this manual WINDOW WALL TYPE ROOM AIR CONDITIONER Prior to installation this air conditioning unit must be submitted for approval by the utility service which provides electricity carefull...

Страница 2: ...turer will take back the old appliance for disposal at least free of charge to the user D As old products contain valuable resources they can be sold to scrap metal dealers Wild disposal of waste in f...

Страница 3: ...ctric shock Do not operate or stop the unit by inserting or pulling out the power plug It may cause electric shock or fire due to heat generation Do not operate with wet hands or in damp environment I...

Страница 4: ...nd turn off the circuit breaker Do not clean unit when power is on as it may cause fire and electric shock it may cause an injury Do not put a pet or house plant where it will be exposed to direct air...

Страница 5: ...by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerni...

Страница 6: ...assistance In a thunderstorm the power must be cut off to avoid damage to the machine due to lightning To reduce the risk of fire or electric shock do not use this fan with any solid state speed contr...

Страница 7: ...s of time 2 Due to the possibility of oxygen deficiency ventilate the room when used together with stoves or other heating devices 3 Do not use this air conditioner for non specified special purposes...

Страница 8: ...of the power cord and wall outlet POWER CORD L E N E Earth wire yellow green N Neutral wire blue L Live wire brown Fig a Wall outlet Air break switch Fig b Power point requirement NOTE To be in compli...

Страница 9: ...hine you purchased may be slightly different Model D Vent Control The vent control is located above the control knobs The operation method is different on different models see the following figures Fo...

Страница 10: ...air conditioner may be slightly different The actual shape shall prevail POWER indicator optional This indicator light remains on when the unit is on and goes off when the SELECTOR is on OFF position...

Страница 11: ...ntain the desired set temperature Thermostat The thermostat is used to set the desired room temperature when the unit is being operated in the COOL MODE NOTE COOLER or HEATER During the cooling operat...

Страница 12: ...hout cooling effect Note When selecting a fan speed the compressor will not run Note When turning the SELECTOR knob from LOW COOL HEAT to HIGH COOL HEAT keep your speed slow as far as possible Do not...

Страница 13: ...be below 40 C to prevent distortion of the filter 4 Rinse off and gently shake off excess water from the filter Allow the filter to dry before replacing it To prevent distortion of the filter do not d...

Страница 14: ...n drain hose locally purchased to the outlet of drain tray Installation procedures of back drainage Fit the seal provided as accessory onto the drain joint Insert the drain joint to the back drainage...

Страница 15: ...OR PARTITION EXTERNAL SUPPORT FRAME AT BALANCE POINT OF A C ALTERNATIVELY BRACKETS AS ILLUSTRATED BELOW MAY BE USED DRAIN PAN 1 To avoid vibration and noise make sure the unit is installed securely an...

Страница 16: ...strips on the housing remain in position 2 Connect the air conditioner to the power and position excess cord length beneath the air conditioner base 3 Engage the chassis fixing brackets into the bott...

Страница 17: ...eft corner int the frame s underside then loosen the frame See Fig 4 Remove the two screws on the left and right chassis fixing brackets then remove the two chassis fixing brackets as shown in Fig 3A...

Страница 18: ...Refer to installation instructions or check with installer Water dripping OUTSIDE when unit is cooling Unit removing large quantity of moisture from humid room This is normal during excessively humid...

Страница 19: ...American Wire Gage Appliance Amps AWG Wire Size 10 13 18 25 18 16 14 12 30 10 Unit dimensions NOTE Value of D is for reference only 3 and 6 6 and 10 10 and 16 16 and 25 MODEL Btu h BODY DIMENSION mm W...