mabe MEV07VQ Скачать руководство пользователя страница 14

13

OPERATING INSTRUCTIONS(continued)

To treat condensed water will be as follows:

Drainage

1.

3

Bottom drainage. Connect drain hose to the bottom drain tray. It will slightly affect cooling 

performance, but will reduce the noise caused by spraying the condensed water.
Note: Only optional for models with bottom drain hole. For pump heating, the bottom drainage 
must be choosed.
2.Back drainage. Connect drain hose to the back drainage hole. 
It will slightly affect cooling performance, but will reduce the noise 
caused by spraying the condensed water.

.Non-drainage. Block the drain hole(s) by rubber plug(s). 

The condensed water will be sprayed to condenser, and 
will improve the cooling performance.

Installation procedures of bottom drainage:
-Remove the rubber plug from the bottom of cabinet(if installed).
-Take out the drain tray and screws from accessary.
-Fix the drain tray onto the bottom of cabinet by screws.
-Connect an extension drain hose (locally purchased) to the outlet of drain tray.

Installation procedures of back drainage:
-Fit the seal (provided as accessory) onto the drain joint.
-Insert the drain joint to the back drainage hole, and 
 rotate it by 90 to be well fitted.
-Connect an extension drain hose (locally purchased) 
 to the drain joint.
-Make sure block the bottom drain hole by rubble plug.
Note: Drain hose is locally purchased according to 
installation length request.

°

RUBBER 
PLUG

Bottom drain hole

RUBBER 
PLUG

SCREW

DRAIN PAN

DRAIN 
OUTLET

SEAL

DRAIN 
JOINT

RUBBER 
PLUG

Back drain 
hole

Bottom drain hole

Back drain 
hole

NOTE: If you choose non-drainage when cooling, both 
the bottom and the back drain holes of the unit should 
be inserted with rubber plugs. When you choose
non-drainage the air conditioner will be perfect cooling efficiency, but big noise may be caused 
by spraying the condensed water. Does not recommend to use.
NOTE: The rated cooling performance is tested under non-drainage status.
NOTE: Make sure that water will not leak from the surrounding area when rubber plug and joint 
were used. Please seal it in case leakage is found.
     

Содержание MEV07VQ

Страница 1: ...please read this manual WINDOW WALL TYPE ROOM AIR CONDITIONER Prior to installation this air conditioning unit must be submitted for approval by the utility service which provides electricity carefull...

Страница 2: ...turer will take back the old appliance for disposal at least free of charge to the user D As old products contain valuable resources they can be sold to scrap metal dealers Wild disposal of waste in f...

Страница 3: ...ctric shock Do not operate or stop the unit by inserting or pulling out the power plug It may cause electric shock or fire due to heat generation Do not operate with wet hands or in damp environment I...

Страница 4: ...nd turn off the circuit breaker Do not clean unit when power is on as it may cause fire and electric shock it may cause an injury Do not put a pet or house plant where it will be exposed to direct air...

Страница 5: ...by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerni...

Страница 6: ...assistance In a thunderstorm the power must be cut off to avoid damage to the machine due to lightning To reduce the risk of fire or electric shock do not use this fan with any solid state speed contr...

Страница 7: ...s of time 2 Due to the possibility of oxygen deficiency ventilate the room when used together with stoves or other heating devices 3 Do not use this air conditioner for non specified special purposes...

Страница 8: ...of the power cord and wall outlet POWER CORD L E N E Earth wire yellow green N Neutral wire blue L Live wire brown Fig a Wall outlet Air break switch Fig b Power point requirement NOTE To be in compli...

Страница 9: ...hine you purchased may be slightly different Model D Vent Control The vent control is located above the control knobs The operation method is different on different models see the following figures Fo...

Страница 10: ...air conditioner may be slightly different The actual shape shall prevail POWER indicator optional This indicator light remains on when the unit is on and goes off when the SELECTOR is on OFF position...

Страница 11: ...ntain the desired set temperature Thermostat The thermostat is used to set the desired room temperature when the unit is being operated in the COOL MODE NOTE COOLER or HEATER During the cooling operat...

Страница 12: ...hout cooling effect Note When selecting a fan speed the compressor will not run Note When turning the SELECTOR knob from LOW COOL HEAT to HIGH COOL HEAT keep your speed slow as far as possible Do not...

Страница 13: ...be below 40 C to prevent distortion of the filter 4 Rinse off and gently shake off excess water from the filter Allow the filter to dry before replacing it To prevent distortion of the filter do not d...

Страница 14: ...n drain hose locally purchased to the outlet of drain tray Installation procedures of back drainage Fit the seal provided as accessory onto the drain joint Insert the drain joint to the back drainage...

Страница 15: ...OR PARTITION EXTERNAL SUPPORT FRAME AT BALANCE POINT OF A C ALTERNATIVELY BRACKETS AS ILLUSTRATED BELOW MAY BE USED DRAIN PAN 1 To avoid vibration and noise make sure the unit is installed securely an...

Страница 16: ...strips on the housing remain in position 2 Connect the air conditioner to the power and position excess cord length beneath the air conditioner base 3 Engage the chassis fixing brackets into the bott...

Страница 17: ...eft corner int the frame s underside then loosen the frame See Fig 4 Remove the two screws on the left and right chassis fixing brackets then remove the two chassis fixing brackets as shown in Fig 3A...

Страница 18: ...Refer to installation instructions or check with installer Water dripping OUTSIDE when unit is cooling Unit removing large quantity of moisture from humid room This is normal during excessively humid...

Страница 19: ...American Wire Gage Appliance Amps AWG Wire Size 10 13 18 25 18 16 14 12 30 10 Unit dimensions NOTE Value of D is for reference only 3 and 6 6 and 10 10 and 16 16 and 25 MODEL Btu h BODY DIMENSION mm W...

Страница 20: ...specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the service we...