• If water enters the unit, turn the unit off at the power outlet

and switch off the circuit breaker. Isolate supply by taking the
power-plug out or disconnect the power supply to the unit,
and contact a qualified service technician.

• This appliance can be used by children aged from 8 years and

above and persons with reduced physical, sensory or mental ca-
pabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning use of the ap-
pliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervi-
sion. (be applicable for the European Countries).

• This appliance is not intended for use by persons (including

children) with reduced physical ,sensory or mental capabilities
or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appli-
ance by a person responsible for their safety. (be applicable for
other countries except the European Countries).

• Children should be supervised to ensure that they do not play

with the appliance.

• If the supply cord is damaged, it must be replaced by the

manufacturer, its service agent or similarly qualified persons in
order to avoid a hazard.

• The appliance shall be installed in accordance with national

wiring regulations.

• Do not operate your air conditioner in a wet room such as a

bathroom or laundry room.

• The appliance with electric heater shall have at least 1 meter

space to combustible materials.

• Contact the authorized service technician for repair or mainte-

nance of this unit.

• Contact the authorized installer for installation of this unit.

• If the air conditioner is knocked over during use, turn off the

unit and unplug it from the main power supply or disconnect
the power supply to the unit, immediately. Visually inspect the
unit to ensure there is no damage.

• If you suspect the unit has been damaged, contact a technician

or customer service for assistance.

• In a thunderstorm, the power must be cut off to avoid damage

to the machine due to lightning.

• To reduce the risk of fire or electric shock, do not use this fan

with any solid-state speed control device.

• Do not run cord under carpeting. Do not cover cord with throw

rugs, runners, or similar coverings. Do not route cord under
furniture or appliances. Arrange cord away from traffic area
and where it will not be tripped over.

Содержание MEV05VV

Страница 1: ...1 owner s manual window type air conditioner model MEV05VV read this manual before installing your new air conditioner PM01...

Страница 2: ...2...

Страница 3: ...product as unsorted munici pal waste Collection of such waste separately for special treatment is necessary It is prohibited to dispose of this appliance in domestic household waste For disposal ther...

Страница 4: ...generation Do not operate with wet hands or in damp environment It may cause electric shock Do not direct airflow at room occupants only This could dam age your health Always ensure effective earthing...

Страница 5: ...d close the window in storm or hurricane Operation with windows opened may cause wetting of indoor and soaking of household furniture Hold the plug by the head of the power plug when taking it out It...

Страница 6: ...play with the appliance If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard The appliance shall be install...

Страница 7: ...vices Do not use this air conditioner for non specified special purposes e g Preserving precision devices food pets plants and art ob jects Usage in such a manner could harm such property cleaning and...

Страница 8: ...o protect the unit Operation will automati cally start after 3 minutes CAUTION Before installing remove all packaging from inside the carton along with any inserts placed into the side louvers note ab...

Страница 9: ...hall be stored in a well venti lated area where the room size corresponds to the room area as specified for operation Any person who is involved with working on or breaking into a refrigerant circuit...

Страница 10: ...e of refrigerant The area shall be checked with an appropriate refrigerant detec tor prior to and during work to ensure the technician is aware of potentially flammable atmospheres Ensure that the lea...

Страница 11: ...rrect specification At all times the manufacturer s maintenance and service guidelines shall be fol lowed If in doubt consult the manufacturer s technical depart ment for assistance The following chec...

Страница 12: ...shall also take into account the effects of ag ing or continual vibration from sources such as compressors or fans 7 Repairs to sealed components 1 During repairs to sealed components all electrical...

Страница 13: ...a leak is suspected all naked flames shall be re moved extinguished If a leakage of refrigerant is found which requires brazing all of the refrigerant shall be recovered from the system or isolated b...

Страница 14: ...m shall be leak tested on completion of charging but prior to commissioning A follow up leak test shall be carried out prior to leaving the site 14 Decommissioning Before carrying out this procedure i...

Страница 15: ...efrig erants are removed safely When transferring refrigerant into cylinders ensure that only ap propriate refrigerant recovery cylinders are employed Make sure that the correct number of cylinders fo...

Страница 16: ...he air conditioner is turned off wait 3 minutes before re starting This allows pressure inside the compressor to equalize Fail ure to follow these instructions may be harmful to your unit power supply...

Страница 17: ...gh efficiency compressors may have a high pitched chatter during the cooling cycle Vibration Unit may vibrate and make noise because of poor wall or window construction or incor rect installation Ping...

Страница 18: ...models Your model may offer slightly different features Cool Mode The desired cool setting is selected by rotating the knob to the ap propriate location HI COOL has maximum cooling effect and airflow...

Страница 19: ...her cool settings Higher cool settings will provide lower room temperature Rotate the thermostat selector counter clockwise for lower cool settings Lower cool settings will provide higher room tempera...

Страница 20: ...Install the unit where the sunlight does not shine directly on the unit If the unit receives direct sunlight build an awning to shade the cabinet 3 There should be no obstacle such as a fence or wall...

Страница 21: ...ar louver Brick wall Air IN 100 mm Air IN Louver Brick wall Front Air OUT 100 mm CAUTION All side louvers of the cabinet must remain exposed to the out side of the structure Note After installing make...

Страница 22: ...the filter can build up and cause an accumulation of frost on the cooling coils Remove the filter by sliding out from the right hand side Wash the filter using liquid dishwashing detergent and warm wa...

Страница 23: ...ording to the installation instruc tions Cover it with plastic or return it to the original carton CAUTION NEVER operate the air conditioner without the air filter as dust dirt particles can contribut...

Страница 24: ...ripping of the com pressor overload Possible causes What to do Air conditioner does not cool as it should do Airflow is restricted Make sure there are no cur tains blinds or furniture blocking the fro...

Страница 25: ...10 10 and 16 16 and 25 Rated current of appliance A Nominal cross section area Suggested minimum wire size AWG American Wire Gage 18 16 14 12 10 10 13 18 25 30 Appliance Amps AWG Wire size Refrigeran...

Страница 26: ...26 notes...

Страница 27: ...27...

Страница 28: ...28...

Отзывы: