When a pump or blower is turned off by a button press or after it has timed out, a clean-up cycle runs for 30 minutes. Pump 1 on Low Speed and the
ozone generator will run for the set time. The pump and the ozone generator will run for 30 minutes or more.
T IM E - O F - DA Y
Setting the time-of-day is important for determining filtration times and other background features. “Set Time” will appear on the display if no time-of-
day is set in the memory. On the Settings Screen, select the Time-of-Day line. On the Time-of-Day screen, simply navigate right and left to select the
Hour, Minutes, AM/PM and 12/24 Hour segments. Use the Up and Down Buttons to make changes.
SAVING SETTINGS
The Time-of-Day screen is a simple, editable screen that illustrates a feature of the control that applies to all other editable screens as well. When
changes are made, the icon to go “Back” changes to “Save” and a new icon for “Cancel” appears under the Save icon. Navigating to the left will
highlight the Save icon, and navigating down from there will allow the user to cancel the pending change. Pressing the “Select” button will save or
cancel the changes and go back to the previous screen.
NOTE: If power is interrupted to the system, you may have to reset your spa’s time.
A DJ US T IN G F ILT RA T IO N
MAIN FILTRATION
Using the same navigation and adjustment as Setting the Time, Filter Cycles are set using a start time and a duration. Each setting can be adjusted in
15-minute increments. The panel calculates the end time and displays it automatically.
FILTER CYCLE 2 - OPTIONAL FILTRATION
Simply navigate to the Filter Cycle 2 line by pressing the Right Navigation Button, and when “NO” is highlighted, press Up or Down to toggle Filter
Cycle 2 on and off. When Filter Cycle 2 is ON, it can be adjusted in the same manner as Filter Cycle1 by navigating to the right. It is possible to overlap
Filter Cycle 1 and Filter Cycle 2.
CIRCULATION PUMP MODES
Some spas may be manufactured with Circ Pump settings that allow programming filtration cycle duration. Some circ Modes are pre-programmed to
operate 24 hours a day and are not programmable.
PURGE CYCLES
In order to maintain sanitary conditions, as well as protect against freezing, secondary water devices will purge water from their respective plumbing by
running briefly at the beginning of each filter cycle.
If the Filter Cycle 1 duration is set for 24 hours, enabling Filter Cycle 2 will initiate a purge when Filter Cycle 2 is programmed to begin.
RE S T RICT IN G O P E RA T IO N
The control can be restricted to prevent unwanted use or temperature adjustments.
Locking the Panel prevents the controller from being used, but all automatic functions are still active. Locking the Settings allows Jets and other
features to be used, but the Set Temperature and other programmed settings
cannot be adjusted. Settings Lock allows access to a reduced selection of menu items. These include Set Temperature, Invert, Lock, Utilities, Information
and Fault Log. They can be seen, but not changed or edited.
UN LO CK IN G