background image

When a pump or blower is turned off by a button press or after it has timed out, a clean-up cycle runs for 30 minutes.  Pump 1 on Low Speed and the 
ozone generator will run for the set time. The pump and the ozone generator will run for 30 minutes or more. 
 
 

T IM E - O F - DA Y

 

 
Setting the time-of-day is important for determining filtration times and other background features. “Set Time” will appear on the display if no time-of-
day is set in the memory. On the Settings Screen, select the Time-of-Day line. On the Time-of-Day screen, simply navigate right and left to select the 
Hour, Minutes, AM/PM and 12/24 Hour segments. Use the Up and Down Buttons to make changes. 
 

SAVING SETTINGS

 

The Time-of-Day screen is a simple, editable screen that illustrates a feature of the control that applies to all other editable screens as well. When 
changes are made, the icon to go “Back” changes to “Save” and a new icon for “Cancel” appears under the Save icon. Navigating to the left will 
highlight the Save icon, and navigating down from there will allow the user to cancel the pending change. Pressing the “Select” button will save or 
cancel the changes and go back to the previous screen. 
NOTE: If power is interrupted to the system, you may have to reset your spa’s time. 
 

A DJ US T IN G  F ILT RA T IO N

 

 

MAIN FILTRATION

 

Using the same navigation and adjustment as Setting the Time, Filter Cycles are set using a start time and a duration. Each setting can be adjusted in 
15-minute increments. The panel calculates the end time and displays it automatically. 
 

FILTER CYCLE 2 - OPTIONAL FILTRATION

 

Simply navigate to the Filter Cycle 2 line by pressing the Right Navigation Button, and when “NO” is highlighted, press Up or Down to toggle Filter 
Cycle 2 on and off. When Filter Cycle 2 is ON, it can be adjusted in the same manner as Filter Cycle1 by navigating to the right. It is possible to overlap 
Filter Cycle 1 and Filter Cycle 2. 
 

CIRCULATION PUMP MODES

 

Some spas may be manufactured with Circ Pump settings that allow programming filtration cycle duration. Some circ Modes are pre-programmed to 
operate 24 hours a day and are not programmable. 
 

PURGE CYCLES

 

In order to maintain sanitary conditions, as well as protect against freezing, secondary water devices will purge water from their respective plumbing by 
running briefly at the beginning of each filter cycle. 
If the Filter Cycle 1 duration is set for 24 hours, enabling Filter Cycle 2 will initiate a purge when Filter Cycle 2 is programmed to begin. 

RE S T RICT IN G  O P E RA T IO N

 

 
The control can be restricted to prevent unwanted use or temperature adjustments. 
Locking the Panel prevents the controller from being used, but all automatic functions are still active. Locking the Settings allows Jets and other 
features to be used, but the Set Temperature and other programmed settings 
cannot be adjusted. Settings Lock allows access to a reduced selection of menu items. These include Set Temperature, Invert, Lock, Utilities, Information 
and Fault Log. They can be seen, but not changed or edited. 

 

UN LO CK IN G

 

Содержание TP600

Страница 1: ..._____________________________________ NOTE The look of your topside control panel design and buttons will vary according to brand and features available on your spa See table below for pictures and ex...

Страница 2: ...PUMPS After the display has gone through screens push Jet button once to start Pump 1 in low speed and again to switch to high speed Push the Pump 2 button if you have a 2nd pump to turn it on The pu...

Страница 3: ...sors within the heater detect a low enough temperature the pump s and the blower automatically activate to provide freeze protection The pump s and blower will run either continuously or periodically...

Страница 4: ...eached or 1 hour has passed After 1 hour the System will revert to Rest Mode This mode can also be reset by entering the Mode Menu and changing it SHOW SET TIME OF DAY Setting the time of day can be i...

Страница 5: ...panel calculates the end time and displays it automatically To enter filter cycles activate temperature flashing and press the Light button repeatedly until the display reads FLTR with a 1 in the bott...

Страница 6: ......

Страница 7: ...erature adjustment can be accessed from this screen The actual water temperature can be seen in large text and the desired or Set Temperature can be selected and adjusted Time of day Ozone operation a...

Страница 8: ...s selected the temperature will continue to change until the button is released or the Temperature Range limits are reached SPA SHORTCUT SCREENS ALL EQUIPMENT ACCESS The Spa Screen shows all available...

Страница 9: ...tion setting Each range maintains its own set temperature as programmed by the user This way when a range is chosen the spa will heat to the set temperature associated with that range High Range may b...

Страница 10: ...the heater and go into an overheat condition EXITING PRIMING MODE You can manually exit Priming Mode by navigating to the Back button on the Priming Mode Screen If you do not manually exit the primin...

Страница 11: ...setting can be adjusted in 15 minute increments The panel calculates the end time and displays it automatically FILTER CYCLE 2 OPTIONAL FILTRATION Simply navigate to the Filter Cycle 2 line by pressin...

Страница 12: ...e Ground Fault Circuit Interrupter GFCI is an important safety device and is required equipment on hot tub installations in North America Used for verifying a proper installation the GFCI Trip Test mu...