MA Lighting Technology GmbH . Dachdeckerstr. 16 . D-97297 Waldbüttelbrunn . www.malighting.com eMail: [email protected]
36
CONFIRM ERRORS:
For confirming error notes. After confirming the symbol changes from red to yellow. After eliminating the error
the color changes to green.
SHOW STATUS / SHOW ERRORS:
- Show Status - Modus: Racks / Crates / Module / Dimmer are displayed as green elements
- Show Error - Modus: errors are displayed within the elements
SHOW LOG:
If this button is activated (button gets dark), messages and errors for racks, modules and dimmers are displayed at
the bottom.
Selecting DIMMER :
With every touch on a green button the level below opens. (e.g. touch on button „rack“ and the level with the
crates opens; touch on button of a crate and the level modules opens...)
Editing Dimmers:
Open window NETWORK DIMMER and select thedimmer yuo want to edit.
●
open NETWORK DIMMER
●
select Rack - Crate - Modul - Dimmer (with mouse or finger touch)
Menu EDIT DIMMER / EDIT MODULE of the selected dimmer opens.
- Button Edit Dimmer / Edit Module toggles between both menues.
- touch the required number and change value with the pop-up calculator.
Note: Values with dark background can be changed via a gradMA console or direct from th eNDP. Values with
grey background can only changed in the NDP - a message pops up.
Jump to next / previous dimmer with the
< >
buttons.