6 Configuration file

 

WIth LoRa Tool App is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to  
enginko). This is very useful especially in case of multiple devices configuration.

 

With 

“Save” 

button an XML file with the actual configuration of the sensor will be generated. This is useful to store or clone the configuration, or to send it to 

 

enginko's support if needed.

 

6.1 Multi  devices  configuration

 

WIth LoRa Tool App is possible to configure many devices in an easy way.  

For multi-configuration is needed at least one XML file with the parameters to set. 

Settings on this file will be applied to all the sensors.

 

With an additional XLS file is possible to load different LoRa configuration parameters (Activation Type, AppKey, AppEUI, NetKey, DevAddress, Band, Private 

 

option) for each sensor, based on DevEUI.

 

When the sensor is approached, if one parameter is different from files, the APP will ask you if you want to overwrite.

 

XLS is prevailing on the XML, so if both files are enabled, if the DevEUI of the device matches one of the DevEUIs in the XLS file, LoRa parameters will be setted  

from this one.

 

These configuration can be done in the in the Settings:

 

Enable or disable the use of the general configuration by file; 
Enable or disable the use of the specific configuration by file;

 

Verify the passwords; 
Writing the passwords.

 

For details on files format please ask to enginko.

 

7 LoRaWEB Tool

 

enginko provides, upon free registration, 

LoRaWEB 

online tool, where for each sensor it is possible to find documentation, javascript  examples for parsing, 

downlink generator and uplink decoder:

 

 

(iot.mcf88.cloud/LoRaWeb)

 

Содержание enginko MCF-LW13IO

Страница 1: ...ion Disposal information for users Pursuant to and in accordance with Article 14of the Directive 2012 19 EU of the European Parliament on waste electrical and electronic equipment WEEE Thebarred symbo...

Страница 2: ...llation has to be done by aqualified electrician The device isintended as subassembly component Itisresponsibility of the assembler of equipment incorporating to ensure that the overall equipment is s...

Страница 3: ...interface the device must be powered through terminals L LINE and N LINE The power status isvisible on the red green led Alwaysvalidate your settings by reading the NFC data after the sensor has rest...

Страница 4: ...m2m Germany GmbH Am Kappengraben 18 20 61273 Wehrheim 06081 5873860...

Страница 5: ...status forces the device to send back an unplink with the new status If the output status isthe same of current one the sensor will not sendback any message Downlink examples hex turn ON the output t...

Страница 6: ...send aduration command Asapplication example to safely turn on an output send aON pulse command for adefined time for example for the maximum allowed interval and before the expiring time another ON p...

Страница 7: ...specification 1 0 2 regional 1 0 2b 4 1Activation The device supports the following activations on aLoRaWAN network 1 NONE sensor not activated 2 OTAA the JoinEUI and the AppKey not setted must be wr...

Страница 8: ...iswrite only in reading the field will always be empty even if set 4 2 Other settings Networksettings pleasekeep Any settings Change itonly if Objenious network isused default_ any Networktype LoRa s...

Страница 9: ...tiple join allowed Counters period min ifcounter enabled this isthe interval in minutes between one measure and the next one The sensor sends one measures for every transmission Value can be between 1...

Страница 10: ...tted to gain access from LoRa Tool to the sensor open the App and set the right values before reading from the device To bring back the sensor to factory default an reset the password a reset code mus...

Страница 11: ...dditional XLS file ispossible to load different LoRa configuration parameters Activation Type AppKey AppEUI NetKey DevAddress Band Private option for each sensor based on DevEUI Whenthe sensor isappro...

Страница 12: ...with the limits for aClass B digital device pursuant to part 15of the FCC Rules These limits are designed to providereasonable protection against harmful interference in aresidential installation This...

Страница 13: ...Germany GmbH Am Kappengraben 18 20 61273 Wehrheim 06081 5873860 12 Contacts enginko Srl ViaRoma 3I 28060 Sozzago NO T 39 0321 15 93 088 E info enginko com PEC enginkosrl legalmail it W enginko com re...

Отзывы: