background image

 

m2m Germany GmbH | Am Kappengraben 18-20 | 61273 Wehrheim | 06081 5873860 

 
 

enginko LoRaWAN® wireless actuator EU863-870

 

8 Payload

 

For payload descriptions, uplinks and downlinks format and available commands please refer to this document:

 

9 Ordering code

 

Code

 

MCF-LW13IO

 

Description

 

MCF-LW13IO-AS  enginko LoRaWAN® wireless  actuator AS920-925 

MCF-LW13IO-US enginko LoRaWAN® wireless actuator US902-928 
MCF-LW13IO-AU enginko LoRaWAN® wireless actuator AU915-928

 

10 Declaration of conformity

 

Hereby, enginko Srl declares that MCF-LW13IO complies with the essential requirements and other relevant provisions of Directive 2014/53/EU.

 

11 FCC compliance for MCF-LW13IO-US

 

This device complies with part  15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and 

 

(2) this device must accept any interference received, including interference that may cause undesired operation.

 

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part  15 of the FCC Rules. These limits are designed to 

 

provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if 
not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference  
will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the 

 

equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

 

Reorient or relocate the receiving antenna.

 

Increase the separation between the equipment and receiver.

 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 
Consult the dealer or an experienced radio/TV technician for help.

 

Any changes or modifications not expressly approved by the party responsible for compliance could void the user

s  authority to operate this equipment.

 

Contains FCC ID: 2AWAL409810

 

 

Содержание enginko MCF-LW13IO

Страница 1: ...ion Disposal information for users Pursuant to and in accordance with Article 14of the Directive 2012 19 EU of the European Parliament on waste electrical and electronic equipment WEEE Thebarred symbo...

Страница 2: ...llation has to be done by aqualified electrician The device isintended as subassembly component Itisresponsibility of the assembler of equipment incorporating to ensure that the overall equipment is s...

Страница 3: ...interface the device must be powered through terminals L LINE and N LINE The power status isvisible on the red green led Alwaysvalidate your settings by reading the NFC data after the sensor has rest...

Страница 4: ...m2m Germany GmbH Am Kappengraben 18 20 61273 Wehrheim 06081 5873860...

Страница 5: ...status forces the device to send back an unplink with the new status If the output status isthe same of current one the sensor will not sendback any message Downlink examples hex turn ON the output t...

Страница 6: ...send aduration command Asapplication example to safely turn on an output send aON pulse command for adefined time for example for the maximum allowed interval and before the expiring time another ON p...

Страница 7: ...specification 1 0 2 regional 1 0 2b 4 1Activation The device supports the following activations on aLoRaWAN network 1 NONE sensor not activated 2 OTAA the JoinEUI and the AppKey not setted must be wr...

Страница 8: ...iswrite only in reading the field will always be empty even if set 4 2 Other settings Networksettings pleasekeep Any settings Change itonly if Objenious network isused default_ any Networktype LoRa s...

Страница 9: ...tiple join allowed Counters period min ifcounter enabled this isthe interval in minutes between one measure and the next one The sensor sends one measures for every transmission Value can be between 1...

Страница 10: ...tted to gain access from LoRa Tool to the sensor open the App and set the right values before reading from the device To bring back the sensor to factory default an reset the password a reset code mus...

Страница 11: ...dditional XLS file ispossible to load different LoRa configuration parameters Activation Type AppKey AppEUI NetKey DevAddress Band Private option for each sensor based on DevEUI Whenthe sensor isappro...

Страница 12: ...with the limits for aClass B digital device pursuant to part 15of the FCC Rules These limits are designed to providereasonable protection against harmful interference in aresidential installation This...

Страница 13: ...Germany GmbH Am Kappengraben 18 20 61273 Wehrheim 06081 5873860 12 Contacts enginko Srl ViaRoma 3I 28060 Sozzago NO T 39 0321 15 93 088 E info enginko com PEC enginkosrl legalmail it W enginko com re...

Отзывы: