Chapter 1 Safety Precautions 

 

■  Before using the product 

To use the product safely and effectively, please read the contents of this manual thoroughly before use. Please 
keep  to  the  safety  precaution,  for  it  is  to  prevent  accidents  and  potential  danger  from  occurring.  Safety 
precaution  is  classified  into  ‘Warning’  and  ‘Caution’  and  their  meanings  are  as  follows

Also  the  indicated 

illustrations on the product and in the manual have the following meanings. 

 

Violating the instruction may result in serious personal injury or death. 

 

Violating the instruction may result in slight personal injury or product damage. 

 

Be cautious, for danger may be present. 

 

Be cautious, for there is a possibility of an electric shock. 

 
■  General Precautions 

Do not press the screen with a hard or sharp object (awl, screwdriver, pen) with too strong a force.   
It may cause malfunction of touch due to damage of the front sheet. 
Do not use or store in an environment with high vibration. 
Do not allow foreign objects such as water, liquids, or metal powders to enter the product. This may cause 
breakage or electric shock. 
Do not allow foreign objects such as water, liquids, or metal powders to enter into the product.   
Use the radio or mobile phone at least 30cm away from the main unit. 
Two or fewer bright spots may appear on the LCD screen, and certain areas may appear brighter, but this is 
not a defect in LCD characteristics. 
Do not store or operate in direct sunlight. Direct sunlight can change the properties of the LCD. 
Do not touch an adaptor or power code with wet hands. It can cause electric shock. 
Do not use this product in explosive environments with flammable liquid, gas, or dust. 
If the product needs long-term storage without using, avoid direct sunlight and keep dry condition. 

 

■  Design Precautions 

For protecting whole control system from outer power input or malfunction of product, protection circuit 
must be installed outside of product.

 

Physical  protection  devices  as  emergency  switch,  limit  switch,  or  motion  interlock  circuit  and  others  to 
prevent a critical damage of whole system’s safety and human accident from the product’s malfunction.   
When  computers  or  other  outer  devices  control  (operation  mode  change)  the  product,  set  interlock  in 

sequence program to protect from any communication errors. 

Input/output  signals  or  communication  cables  must  have  at  least  100mm(3.94inch)  distance  from  power 
cable or high-tension wire. Especially communication cables must be set apart from power cables. 

 

■  Wiring Precautions 

Be  sure  the  wiring  is  done  correctly  by  checking  the  product’s  rated  voltage  and  the  terminal  layout. 
Incorrect wiring could result in fire, damage or malfunctions. 
Tighten the terminal screw with the specified torque. If the screws of terminal are loose, it could result in 
short circuit, fire, malfunctions. FG Terminal must be used a dedicated ground. Not doing so could result in 

Содержание BOX-HMI Series

Страница 1: ...55 Korea Tel 82 70 465 3366 Fax 82 31 465 3355 www m2i co kr 1 16 M2I Corporation Industrial BOX HMI TOPRP1000D Hardware Manual Thank you for purchasing the industrial BOX HMI series of M2I corporatio...

Страница 2: ...ons 6 Chapter 4 Part Names and General Specifications 7 4 1 TOPRP1000D 7 4 2 Product Dimension 7 4 3 Part Names and General Specifications 7 Chapter 5 External Device Interface 8 5 1 Serial Communicat...

Страница 3: ...nit Two or fewer bright spots may appear on the LCD screen and certain areas may appear brighter but this is not a defect in LCD characteristics Do not store or operate in direct sunlight Direct sunli...

Страница 4: ...product is left without using in long term it must be recharged and stored in room temperature The space between back of product and back of control board must be more than 100mm for maintenance and v...

Страница 5: ...ns and controls with other devices by RS 232C RS 422 485 or Ethernet Also this product can check the management status by connecting to outer display device 2 2 Package Contents The components of the...

Страница 6: ...Built in by Battery 3 3 HDMI Output HDMI Version HDMI v1 4a Resolution 1280 x 720 1024x768 640x480 Set in TDS S W 3 4 Environment Specifications Operation Temperature 10 50 Storage Temperature 20 60...

Страница 7: ...35 Simin daero 327beon gil Dongan gu Anyang si Gyeonggi do 14055 Korea Tel 82 70 465 3366 Fax 82 31 465 3355 www m2i co kr 7 16 Chapter 4 Part Names and General Specifications 4 1 TOPRP1000D 4 2 Produ...

Страница 8: ...5mm 3P Power Input 11 Status LED 3 LEDs Status display of Power Operation and SD Card 12 USB HOST 2 USB A type USB Connecting Port 5V 0 5A Output 13 ETHERNET Port RJ45 2ch 10BASE T 100BASE TX Auto MD...

Страница 9: ...0 2A 5 1 4 COM2 Connector pin number and Signal name Type Pin No Signal Direction Meaning 9Pin Female 1 RDA RD Input RS 422 485 Receive Data 2 RD RxD Input RS 232C Receive Data 3 SD TxD Output RS 232...

Страница 10: ...hen it is connected directly Cross Cable should be used Ex Cross Cable Wiring In the above wiring diagram TD and RD are changed and TD and RD are exchanged 5 3 USB Specifications 5 3 1 USB Host Type I...

Страница 11: ...chanical hazards for safe use 2 The installation should be done in 10 50 and 10 80 environment 3 If this product is installed in sealed space cooling fan must be installed 4 Do not make power cable an...

Страница 12: ...bracket 2 When a VESA Bracket is attached four fixing grooves should be put correctly Chapter 7 Wiring 7 1 Power Cable Wiring 1 The Power cable should have the following specification Power Cable Spec...

Страница 13: ...tric shocks from abnormal cable connection User should be well informed about this Pin Terminal guide mm B L F E D d 1 8 2 0 22 18 12 14 5 3 3 3 8 2 2 5 3 Wiring of power is as follows 7 2 Ground Wiri...

Страница 14: ...uide 1 Put HDMI or USB cables through cable clamp as following image 2 Tighten the cable and clamp as following image and use screw and bolt to fix the clamp to a product Chapter 8 Maintenance 8 1 Cas...

Страница 15: ...in the manual 5 When electromagnetic noise is over radiated Install the ferrite core to the body power and field power lines Depending on the installation environment noise from power lines and commun...

Страница 16: ...del Name TOPRP1000D Operating Temp 10 Ta 50 Power Specifications 24Vdc 10W or under Inside Cell MS920SE Rechargeable lithium Battery irreplaceable Copyright M2I Corporation 2022 08 www m2i co kr Pleas...

Отзывы: