USER NOTICE   

1. Safety Precaution 

1. 

Carefully  open  the  box,  avoid  the  accessories,  like  lens,  dropping  to  ground  and  being 

damaged.

 

2.

 

Check  the  input  voltage,  be  sure  the  input  voltage  which  signed  on  the  microscope  is 

consistent with the power supply voltage, or it will bring a serious damage to the instrument. 

3.

 

Do keep the instrument out of direct sunlight, high temperature or humidity, dusty and easy 

shaking environment. Make sure the stage is smooth, horizontal and firm enough. 

4.

 

To prevent the microscope body from turning over, its pivot angle must be limited to 30

°

.   

5.

 

.A microscope is a precision instrument. Handle it with care and avoid subjecting it to sudden 

or severe impact.   

6.

 

Make sure the instrument is earthed, to avoid lighting strike. 

7.

 

Do not disassemble any part of the microscope, especially the electrical parts on the bottom 

side as this may result in electric shock. 

8.

 

Use the factory supplied power cord, please. 

2. Maintenance and Storage 

1.

 

All  the  lenses  have  been  well  checked  and  adjusted.  It  is  forbidden  to  disassemble  them 

yourself. 

2.

 

The  binocular  viewing  head  and  focusing  unit  have  a  compact  and  precise  frame;  please 

don’t disassemble them as possibly as you can. 

3.

 

Keep the instrument clean, wipe dust regularly, and be attention to avoid contaminating the 

optical elements especially.   

4.

 

The contaminations on the prism, as fingerprint and oil, could be gently wiped with a piece 

of  soft  cloth  or  tissue  paper,  gauze  which  has  been  immersed  in  pure  alcohol  or  ether. 

(

Note that the alcohol and ether are highly flammable, do keep them away from the 

fire or potential sources of electrical sparks, and use them in a drafty room as possible 

as you can.) 

5.

 

Do not attempt to use organic solvents to clean the microscope components other than the 

glass  components.  To  clean  them,  use  a  lint-free,  soft  cloth  slightly  moistened  with  a 

diluted neutral detergent.   

Содержание PZ-4

Страница 1: ...l is written for stereomicroscope To ensure the safety obtain optimum performance and to familiarize yourself fully with the use of this microscope it is recommended strongly that you study this manua...

Страница 2: ...2 1 Components 4 2 Assembly 5 2 1 Assembly diagram 5 2 2 Detailed Assembly Procedure 6 3 Adjustment and Operation 9 3 1 Adjusting binocular head 9 3 2 Focus adjustment 10 4 Specification 11 5 Troubles...

Страница 3: ...ottom side as this may result in electric shock 8 Use the factory supplied power cord please 2 Maintenance and Storage 1 All the lenses have been well checked and adjusted It is forbidden to disassemb...

Страница 4: ...wer at once and wipe up the moisture 7 Do not disassemble any parts of the microscope which will affect the function or decline the performance of the microscope 8 Place the instrument in a cool dry p...

Страница 5: ...tereo Microscope Adjustable WF10 eyepieces Focusing Assembly Binocular viewing head Zoom body Clamping Knob Objectives Glass stage Standard base Brightness adjusting knob Power cord Main Switch Coarse...

Страница 6: ...bers indicate the order of assembly When assembling the microscope make sure that all parts are free of dust and dirt and avoid scratching any parts or touching glass surfaces Power cord Microscope ma...

Страница 7: ...ewing head into the mounting port on the zoom body and tighten the viewing head clamping screw with provided hexagonal driver Note Working Environment Requirement 1 Ambient temperature 5 C to 40 C 41...

Страница 8: ...e eyepiece as in Fig 5 When Not Wearing Eyeglasses Extend the folded eyeshades This makes observation easier by preventing the inverse incidence of light from between the eyepiece and your eyes 2 2 4C...

Страница 9: ...depth The size of aperture iris diaphragm can be adjusted Switch the lever to left to open the aperture iris diaphragm to the right to close the aperture iris diaphragm Check the effect during observa...

Страница 10: ...or 6 4 or 10 and turn the focusing knob to focus the specimen 4 Rotate the zoom body knob to the lowest magnification 0 8 looking only into the left eyepiece adjust the diopter ring on left eyepiece...

Страница 11: ...knob to increase or decrease the focus knob tension 3 Brightness adjustment the right brightness adjustment knob is used to adjust the bottom illumination and the left brightness adjustment knob is us...

Страница 12: ...Ratio 1 6 1 8 1 10 Objective Magnification 0 8 5 0 8 6 4 0 8 8 Eyepiece 24 10 WF Diopter adjustable Binocular Viewing Head Inclined at 20 interpupillary distance range 50 75mm Working Distance 78mm V...

Страница 13: ...adjustment ring is too tight Loosen it properly 8 6 Zoom microscope body drops or specimen goes out of focus during observation Tension adjustment ring is too loose Tighten it properly 8 6 Outfit Comp...

Отзывы: