background image

CABLE ROUTING

 

Note: 

When cable routing, each axis should be positioned at the centers of each travel spectrum. Az: If your AZ 

is set for south center, then position the AZ at 180 deg. EL: if your EL is set for 0 to 90 deg. The set your EL for 

45 deg. This way the cables will only need to flex for 1/2 of the total movement on each direction of rotation.

 

 

Elevation Loop

 

The Elevation axis control cable comes up through the AZ assembly cable pass through and attaches to the 

elevation motor unit.  Note the RF cables from the antennas come from either side of the H

-

Frame and onto the 

cable bridge then they should loop around the Elevation axis body then down through the cable pass through. 

The loop around the Elevation body will provide a loop that will expand and contract as the elevation moves up 

or down in rotation.  Temporarily use electrical tape or nylon ties to hold the cables together and to the cable 

brace. Drive the Elevation axis to both ends of the travel and watch the cables to be sure they do not become to 

tight or get hung up. Make adjustments as needed, this may take multiple passes to feel comfortable with the 

cable rap and cable loop. Once you feel comfortable with the cable rap and its movement add nylon ties to the 

cable brace. Note: multiple slots have been added to the cable brace to give adequate positions for small and 

large cable bundles. Taping or the use of nylon tie to keep the bundle together below the cable pass through is 

recommended

 

 

NOTE:

 

GENERIC POWER DIVIDER

 

BRIDGE SHOWN FOR 

 

CABLE ROUTE EXAMPLE.

 

 

POWER DIVIDER BRIDGE

 

SETUP MAY BE DIFFERENT.

 

REFER TO MASTER SYSTEM

 

MANUAL FOR MORE DETAILS.

 

LARGE NYLON TIES

 

TO HOLD DOWN

 

POWER DIVIDERS

 

AND OR FEED LINES

 

Содержание FGAE1000-D1-W-COS-A-H

Страница 1: ...c com 2018 M2 Antenna Systems Incorporated 12 20 21 REV A M2 Antenna Systems Inc Model No FGAE1000 D1 W COS A H SPECIFICATIONS Model FGAE1000 D1 W C A H Motor Type DC Motor Worm Gear Configuration Sin...

Страница 2: ...e the assembly process to meet specific site requirements A quick review of the assembly notes and drawings should help firm up the appropriate strategy Please remember to double check all hardware fo...

Страница 3: ...SS QTY 6 BOLT 5 16 18 X 2 0 HEX HD SS QTY 2 FLATWASHER 5 16 SS QTY 2 LOCKNUT 5 16 18 SS QTY 2 PIPE STOP AZ 1000 ASSEMBLY BOLT 3 816 X 1 0 SCKT HD SS QTY 6 3 PIPE CUSTOMER SUPPLIED PIPE CLAMP 1 QTY 3 P...

Страница 4: ...E1000 D1 W COS A H ASSEMBLY BOLT 3 8 16 x 1 SS QTY 5 AZ 1000W BOLT 3 8 16 x 1 SS QTY 5 BOLT 3 8 16 x 3 4 SS QTY 1 CROSS BOOM PLUG IN USE BOLT 1 4 20 X 3 SS LOCKNUT 1 4 20 SS BOTH SIDES AZ 1000W EL 100...

Страница 5: ...CABLE BRIDGE ARM FGAE1000 D1 W C0S A H ASSEMBLY CABLE BRIDGE BOLT 1 4 20 X 1 0 SS LOCKNUT 1 4 20 SS 2 4 CRADLE BOLT 1 4 20 X 3 5 SS LOCKNUT 1 4 20 SS ON CENTER CABLE PASS THROUGH...

Страница 6: ...able bridge can collide with the cable routing bar and associated cables When mounting the cable bridge be sure the elevation system is on the horizon then position the cable bridge 10 30 degrees belo...

Страница 7: ...the cable routing process by allowing the cable to pass through the Azimuth axis This simple change can save on costly repairs when cable get snagged keeping the system from performing LARGE NYLON TIE...

Страница 8: ...will expand and contract as the elevation moves up or down in rotation Temporarily use electrical tape or nylon ties to hold the cables together and to the cable brace Drive the Elevation axis to bot...

Страница 9: ...to the AZ axis then loops down and back to the full cable bundle coming from the bottom of the cable pass through 6 to 12 inches below the exit of the pass through Taping or the use of nylon tie to k...

Страница 10: ...OLT 1 4 20 X 1 0 HEX HEAD S S 2 LOCK NUT 1 4 20 S S 6 SCREW 8 32 X 1 2 SET S S 4 ALLEN KEY 5 64 1 OPTIONAL KITS PIPE MOUNT KIT 3 FGAEPMK3 DESCRIPTION QTY 3 PIPE CLAMP M2AMC0144 3 3 PIPE CLAMP CAP M2AM...

Страница 11: ...onstant through the limit switches and through to the positioner When the limit switch is activated it breaks the contact and stops the cur rent from continuing Reversing the positioner in the opposit...

Страница 12: ...Red Black wires as shown Slide the prepared 2 Conductor Red Black 16AWG wire through the cord grip from the front of the panel Route the Red wire to position A as shown below Then route the Black wire...

Страница 13: ...itioner unit that DOES NOT have cord grips or wires running into it You will see the limit switches A B the limit arm C and limit screw D as pictured to the right We have not installed the limit screw...

Страница 14: ...mended 1 year maintenance 1 Visual inspection of complete system look for rust or corrosion and loose hardware 2 Manually move each axis individually and LISTEN for smooth operation 3 Check cables for...

Страница 15: ...ss C Check gears for foreign debris D Adjust thrust block adjustment 4 Excess backlash A Inspect worm and worm gear for wear B Inspect for thrust block bearing wear C Inspect system for loose hardware...

Страница 16: ...rotation of the adjustment bolt will move the adjustment block down moving the worm closer to the worm gear and removing backlash 5 Counter clockwise rotation of the adjustment bolt will move the adju...

Страница 17: ...FUL not to overfill SEAL as ex cess pressure can blow SEAL 4 Tighten SET SCREW until flush with aluminum housing COVER SEAL FLANGE FILL LINE HOLE WITH SET SCREW COVER SEAL FLANGE is used in multiple l...

Страница 18: ...or inability to use the product Some states or provinces do not allow the exclusion or limitation of liability for consequential or incidental damages so the above limitation may not apply In the even...

Отзывы: