M-system W5 Series Скачать руководство пользователя страница 2

MODEL: W5VS

[5] OPTIONS (multiple selections)

Response Time (0 – 90 %)

blank: Standard (≤ 0.5 sec.)
/K: Fast Response (Approx. 25 msec.)

Other Options

blank: none
/Q: Option other than the above (specify the specification)

SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)

/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating

ADJUSTMENT

/V01: Multi-turn fine adjustment
/VN: Sealed adjustment holes

GENERAL SPECIFICATIONS

Construction: Terminal block
Connection
  Input: M3.5 screw terminals (torque 0.8 N·m)
  Output & power: M3 screw terminals (torque 0.8 N·m)
Screw terminal: Nickel-plated steel
Housing material: Flame-resistant resin (black)
Isolation: Input to output 1 to output 2 to power
Overrange output: Approx. -10 to +120 % at 1 – 5 V
Zero adjustment: -2 to +2 % (front)
(±1 % with the input suffix codes 4W and 5W selected)
Span adjustment: 98 to 102 % (front)
(99 to 101 % with the input suffix codes 4W and 5W
selected.)

INPUT SPECIFICATIONS

■ DC Current: Input resistor incorporated
Specify input resistance value for code Z.
(R ≤ 0.125 W ÷ [F.S. Current]

2

)

■ DC Voltage
Input resistance: 1 MΩ min.; 10 kΩ min. for the input code
02
10 kΩ min. at power loss
•Input code 0 (Not CE)
 Voltage range: -300 – +300 V DC
 Minimum span: 100 mV
 Offset: Max. 1.5 times span
•Input code 01 (CE)
 Voltage range: -70 – +70 V DC
 Minimum span: 100 mV
 Offset: Max. 1.5 times span
•Input code 02 (Not CE)
 Voltage range: -100 – +100 mV DC
 Minimum span: 5 mV

 Offset: Max. 1.5 times span

OUTPUT SPECIFICATIONS

■ DC Current: 0 – 20 mA DC
  Minimum span: 1 mA
  Offset: Max. 1.5 times span
  Load resistance: Output drive 11 V max.
■ DC Voltage: -10 – +12 V DC
  Spans: Min. 5 mV, max. 20 V
  Offset: Max. 1.5 times span
  Load resistance: Output drive 10 mA max.; 5 mA for
negative  voltage output; at ≥ 0.5 V

INSTALLATION

 Power Consumption
•AC:
 Approx. 4 VA at 100 V
 Approx. 5 VA at 200 V
 Approx. 6 VA at 264 V
•DC: Approx. 3 W
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 0 to 90 %RH (non-condensing)
Mounting: DIN rail
Weight: 130 g (0.29 lbs)

PERFORMANCE in percentage of span

Accuracy: ±0.1 %
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength:
2000 V AC @1 minute (input to output 1 or output 2 to
power to ground)
1000 V AC @1 minute (output 1 to output 2)

STANDARDS & APPROVALS

CE conformity:
EMC Directive (2004/108/EC)
  EMI EN 61000-6-4: 2007
  EMS EN 61000-6-2: 2005

Rugghölzli 2
CH - 5453 Busslingen

Tel. +41 (0)56 222 38 18

Fax +41 (0)56 222 10 12

[email protected]

www.sentronic.com

Produkte, Support und Service

SENTRONIC

AG

Содержание W5 Series

Страница 1: ...oltage See INPUT SPECIFICATIONS CE not available Power suffix code M R2 P only 01 Specify voltage See INPUT SPECIFICATIONS Choose 01 for CE Power suffix code R only 02 Specify voltage See INPUT SPECIFICATIONS CE not available Power suffix code M R2 P only 2 OUTPUT 1 Current A 4 20 mA DC Load resistance 550 Ω max B 2 10 mA DC Load resistance 1100 Ω max C 1 5 mA DC Load resistance 2200 Ω max D 0 20 ...

Страница 2: ...t code 0 Not CE Voltage range 300 300 V DC Minimum span 100 mV Offset Max 1 5 times span Input code 01 CE Voltage range 70 70 V DC Minimum span 100 mV Offset Max 1 5 times span Input code 02 Not CE Voltage range 100 100 mV DC Minimum span 5 mV Offset Max 1 5 times span OUTPUT SPECIFICATIONS DC Current 0 20 mA DC Minimum span 1 mA Offset Max 1 5 times span Load resistance Output drive 11 V max DC V...

Страница 3: ...U V POWER 10 11 Input shunt resistor attached for current input Remark 1 The section enclosed by broken line is only with 2nd output option Remark 2 DO NOT connect to the terminals 1 2 3 INPUT OUTPUT 1 Isolation S Z Output Driver S Z Output Driver OUTPUT 2 6 7 8 9 Specifications are subject to change without notice Rugghölzli 2 CH 5453 Busslingen Tel 41 0 56 222 38 18 Fax 41 0 56 222 10 12 mailbox...

Страница 4: ...ot install the unit where it is subjected to continuous vibration Do not subject the unit to physical impact Environmental temperature must be within 5 to 55 C 23 to 131 F with relative humidity within 0 to 90 RH in order to ensure adequate life span and operation WIRING Do not install cables power supply input and output close to noise sources relay drive cable high frequency line etc Do not bind...

Страница 5: ...output 2 whenever the output 1 is adjusted Note Remove the sealing label for VN option MAINTENANCE Regular calibration procedure is explained below CALIBRATION Warm up the unit for at least 10 minutes Apply 0 25 50 75 and 100 input signal Check that the output signal for the respective input signal remains within accu racy described in the data sheet When the output is out of tolerance recalibrate...