5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-7777-F  Rev.2  P. 1 / 9

INSTRUCTION MANUAL

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If you have any problems or questions with the product, 
please contact M-System’s Sales Office or representatives.

 

PACKAGE INCLUDES:

High-speed DC voltage output module ..............................(1)
DIN rail mounter slider ......................................................(2)

 

MODEL NO.

Confirm Model No. marking on the product to be exactly 
what you ordered.

 

INSTRUCTION MANUAL

This manual describes necessary points of caution when 
you use this product, including installation, connection and 
basic maintenance procedures.

POINTS OF CAUTION

 

CONFORMITY WITH EU DIRECTIVES

• Use dual-shield cables (Shinko Seisen Industry Model 

ZHY262 PBA) for the network.  If it is not sufficient, use 
a ferrite core (Kitagawa Industries Model  GRFC-13) for 
the network cable.

• The equipment must be mounted inside the instrument 

panel of a metal enclosure.

• The actual installation environments such as panel con-

figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated 
in a panel system.  The user may have to review the CE 
requirements in regard to the whole system and employ 
additional protective measures to ensure the CE conform-
ity.

 

POWER INPUT RATING & OPERATIONAL RANGE

• Locate the power input rating marked on the product and  

confirm its operational range as indicated below:

    24V DC rating: 24V DC ±10%, approx. 70mA

 

GENERAL PRECAUTIONS

• Before you remove the unit or mount it, turn off the power 

supply and output signal for safety.

• Before you remove the terminal block or mount it, make 

sure to turn off the power supply and output signal for 
safety.

• DO NOT set the switches on the module while the power 

is supplied.  The switches are used only for maintenance 
without the power.

 

ENVIRONMENT

• Indoor use.
• When heavy dust or metal particles are present in the 

air, install the unit inside proper housing with sufficient 
ventilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -10 to +55°C 

(14 to 131°F) with relative humidity within 30 to 90% RH 
in order to ensure adequate life span and operation.

 

WIRING

• Do not install cables close to noise sources (relay drive 

cable, high frequency line, etc.).

• Do not bind these cables together with those in which 

noises are present.  Do not install them in the same duct.

• Be sure to close the terminal cover for safety.

 

AND ....

• The unit is designed to function as soon as power is sup-

plied, however, a warm up for 10 minutes is required for 
satisfying complete performance described in the data 
sheet.

HI-SPEED LINK SYSTEM I/O MODULE

(high-speed DC voltage output, 4 points, isolated, screw terminal block)

MODEL

R7G4HH-A-YVF4

Содержание R7G4HH-A-YVF4

Страница 1: ...to ensure the CE conform ity POWER INPUT RATING OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below 24V DC rating 24V DC 10 appr...

Страница 2: ...ormal Turns off when the internal power is abnormal RUN Green Turns on when the refresh data is received normally Turns off when no communication or communication error ERR Red Turns off when output c...

Страница 3: ...ed to the output reset value Transfer Rate SW1 8 SW1 8 TRANSFER RATE OFF 12Mbps ON 6Mbps Note Be sure to set unused SW1 1 and 1 2 to OFF TERMINATING RESISTOR To use the terminating resistor turn the s...

Страница 4: ...f duplex communication 12345678 12345678 1 NC 2 NC 3 NC 4 TR 5 TR 6 NC 7 NC 8 SLD Unused Unused Unused Network Network Unused Unused Shield Full duplex communication Communication connector pin assign...

Страница 5: ...move the upper hook of the unit from the DIN rail 1 2 3 DIN RAIL MOUNTING RIGHT ANGLE Mounting 1 Insert the longer DIN rail mounter slider until it clicks twice as shown below 1 2 Set the upper hook a...

Страница 6: ...F Rev 2 P 6 9 TERMINAL CONNECTIONS Connect the unit as in the diagram below EXTERNAL DIMENSIONS unit mm inch 130 5 12 140 5 51 152 5 98 4 16 50 1 97 5 2 4 16 4 5 18 dia 6 18 M3 Output terminal screws...

Страница 7: ...3 17 8 9 VH3 VL3 COM3 13 VH1 VL1 COM1 4 5 15 VH2 VL2 COM2 6 7 4 5 3 6 PAIR WIRING Ethernet cable pin assignment 4 5 6 7 8 2 3 NC TXD TR 1 NC RXD NC RXD NC NC SLD TXD TR 4 5 6 7 8 2 3 NC 1 NC NC SLD 6...

Страница 8: ...ELD Full duplex communication Half duplex communication MASTER CONNECTION Terminating Resistor MOUNTING REQUIREMENTS unit mm inch 140 5 51 2 M4 WIRING INSTRUCTIONS TORQUE Wiring screw for separable te...

Страница 9: ...gurable with the configurator software model R7CFG Refer to the software manual for details ADD n ADD n ADD n 2 ADD n 1 ADD n 4 ADD n 2 ADD n 6 ADD n 3 Data is represented in 16 bit binary Negative va...