background image

R7D-YS2

EM-7802-E  Rev.6  P. 4 / 10

TERMINAL CONNECTIONS

Connect the unit as in the diagram below.

 

EXTERNAL DIMENSIONS  unit: mm (inch)

2

3

4

1

5

10

7

8

9

6

2 3 4

1

5

30 (1.18)

[5 (.20)]

3 (.12)

3 (.12)

5.5 (.22)

DIN RAIL

35mm wide

54 (2.13)

17 (.66)

50 (1.97)

18.5 (.73)

115 (4.53)

10–M3 SCREW 

TERMINALS

for OUTPUT

6 (.24)

TERMINAL BLOCK for

DeviceNet, POWER

 

CONNECTION DIAGRAM

7

I0

2

COM0

9

4

OUTPUT 0

I1

COM1

OUTPUT 1

CAN_L

V–

Drain

CAN_H

V+

EXTENSION CONNECTOR

056 222 38 18

[email protected]

www.sentronic.com

SENTRONIC

AG

Содержание R7D-YS2/UL

Страница 1: ...p to 2000 meters This equipment must be mounted inside a suitable fire enclosure This equipment is to be supplied by a Class 2 power sup ply CONFORMITY WITH EU DIRECTIVES The equipment must be mounted...

Страница 2: ...ch 5 4 3 2 1 0 9 8 7 6 Baud Rate Setting 0 125 kbps factory setting 1 250 kbps 2 500 kbps 3 thr 9 Auto tracking The R7D communicates in the baud rate setting detected at the startup with the switch se...

Страница 3: ...out 0 0 3276 7 sec 1 0 sec Status Data ON Disable OFF Enable OFF Enable Serial ID English one byte characters within 8 characters CHANNEL INDIVIDUAL SETTING PARAMETER SETTING RANGE DEFAULT SETTING Zer...

Страница 4: ...9 6 2 3 4 1 5 30 1 18 5 20 3 12 3 12 5 5 22 DIN RAIL 35mm wide 54 2 13 17 66 50 1 97 18 5 73 115 4 53 10 M3 SCREW TERMINALS for OUTPUT 6 24 TERMINAL BLOCK for DeviceNet POWER CONNECTION DIAGRAM 7 I0 2...

Страница 5: ...0 Begin 0 CH0 CH1 1 2 Output Data Example 2 Analog Output Module R7D EC16x with Status Analog Output Module R7D EC16x Input Data I O DATA DESCRIPTIONS 0 15 16 bit binary data Negative values represent...

Страница 6: ...TUS Status signal can be included in the transmission data when the setting is enabled using the PC Configurator soft ware model R7CON For details refer to STATUS in I O DATA DESCRIPTIONS STATUS OUTPU...

Страница 7: ...a thick cable to maintain low imped ance at high frequency Use shielded cables for the signals taken out of the control panel Choose a thick and short cable to ground the FG terminal of the R7D module...

Страница 8: ...d the panel cover with an earth strap grounding may be strengthened and EMC may be improved Ground the control panel at low impedance using e g braided wires Keep the opening for ventilation as small...

Страница 9: ...cautions are illustrated in the next page Keep cables as short as possible It prevents noise emissions from the cables and noise overlapping to the cables Attach a ferrite core to reduce noise impact...

Страница 10: ...pplicable when wiring the R7D Series To external apparatus Keep the cable as short as possible To external apparatus Shielded Cable Earth Clamp Remove a part of the shielded cable cover and ground it...

Отзывы: