R7D-YS2

EM-7802-E  Rev.6  P. 2 / 10

COMPONENT IDENTIFICATION

5

4

3

2 1 0 9

8

7

6

5

4

3

2 1 0 9

8

7

6

5

4

3

2 1 0 9

8

7

6

MS

X10

X1

NODE ADD.

B.RATE

CNFG.

1 2 3 4 5 6 7 8

NS

2 3 4

1

5

2

3

4

1

5

10

7

8

9

6

(A)  Status Indicator LED
(B)  Node Address Setting Rotary SW
(C)  Baud Rate Setting Rotary SW
(D)  Operating Mode Setting DIP SW (SW1)
(E)  PC Configurator Jack
(F)  DeviceNet, Power Supply Terminals
(G)  Output Terminals

(A)

(F)

(G)

(B)

(C)

(D)

(E)

 

STATUS INDICATOR LED

ID

STATE

TO INDICATE

MS

Green

Operating in a normal condition

Blinking Green Standby (needs commissioning)

Red

Critical failure

Blinking Red

Minor failure

OFF

No power supplied

NS

Green

Link on-line and connections in the 
established state

Blinking Green Link on-line but no connections in 

the established state

Red

Critical link failure

Blinking Red

Minor link failure

OFF

No power supplied

 

NODE ADDRESS

Node Address is selected between 1 and 63 in decimal.  The
left switch determines the tenth place digit, while the right
switch does the ones place digit of the address.

5

4

3

2

1

0

9

8

7

6

5

4

3

2

1

0

9

8

7

6

Node Address Setting (x1)

Factory setting : 00

Node Address Setting (x10)

 

BAUD RATE

Baud Rate is selected with the rotary switch.

5

4

3

2

1

0

9

8

7

6

Baud Rate Setting

0 : 125 kbps (factory setting)
1 : 250 kbps
2 : 500 kbps
3 thr. 9 : Auto-tracking

The R7D communicates in the baud rate setting detected at 
the startup with the switch set to the positions 0 (125 kbps), 
1 (250 kbps) or 2 (500 kbps).
For the settings 3 through 9, it analyzes the PLC’ s network 
to determine the baud rate on the network.

 

OPERATING MODE

(*) Factory setting

• Extension: SW1-1, 1-2

SW1-1

SW1-2 EXTENSION

OFF

OFF

No extension (*)

ON

OFF

Discrete input, 8 or 16 points

OFF

ON

Discrete output, 8 or 16 points

• Output at the Loss of Communication: SW1-4

SW1-4

OUTPUT AT THE LOSS OF COMMUNICATION

OFF

Reset the output (to -15%)

ON

Hold the output (*)
(maintains the last data received normally)

Note:  Be sure to set unused SW1-3 and 1-5 through 1-8 to 

OFF.

 

DeviceNet TERMINAL ASSIGNMENT

2

3

4

1

5

NO.

ID

FUNCTION, NOTES

1

V+

Network power

2

CAN_H

Network data High

3

Drain

Shield

4

CAN_L

Network data Low

5

V–

Network power supply –

 

OUTPUT TERMINAL ASSIGNMENT

6

NC

7

I0

8

NC

1

NC

2

COM0

3

NC

9

I1

4

COM1

10

NC

5

NC

NO.

ID

FUNCTION

NO.

ID

FUNCTION

1

NC

No connection

6

NC

No connection

2 COM0 Common 0

7

I0

Current 0

3

NC

No connection

8

NC

No connection

4 COM1 Common 1

9

I1

Current 1

5

NC

No connection

10

NC

No connection

 

EXTENSION MODULE

Combinations with all extension modules are selectable.

056 222 38 18

[email protected]

www.sentronic.com

SENTRONIC

AG

Содержание R7D-YS2/UL

Страница 1: ...p to 2000 meters This equipment must be mounted inside a suitable fire enclosure This equipment is to be supplied by a Class 2 power sup ply CONFORMITY WITH EU DIRECTIVES The equipment must be mounted...

Страница 2: ...ch 5 4 3 2 1 0 9 8 7 6 Baud Rate Setting 0 125 kbps factory setting 1 250 kbps 2 500 kbps 3 thr 9 Auto tracking The R7D communicates in the baud rate setting detected at the startup with the switch se...

Страница 3: ...out 0 0 3276 7 sec 1 0 sec Status Data ON Disable OFF Enable OFF Enable Serial ID English one byte characters within 8 characters CHANNEL INDIVIDUAL SETTING PARAMETER SETTING RANGE DEFAULT SETTING Zer...

Страница 4: ...9 6 2 3 4 1 5 30 1 18 5 20 3 12 3 12 5 5 22 DIN RAIL 35mm wide 54 2 13 17 66 50 1 97 18 5 73 115 4 53 10 M3 SCREW TERMINALS for OUTPUT 6 24 TERMINAL BLOCK for DeviceNet POWER CONNECTION DIAGRAM 7 I0 2...

Страница 5: ...0 Begin 0 CH0 CH1 1 2 Output Data Example 2 Analog Output Module R7D EC16x with Status Analog Output Module R7D EC16x Input Data I O DATA DESCRIPTIONS 0 15 16 bit binary data Negative values represent...

Страница 6: ...TUS Status signal can be included in the transmission data when the setting is enabled using the PC Configurator soft ware model R7CON For details refer to STATUS in I O DATA DESCRIPTIONS STATUS OUTPU...

Страница 7: ...a thick cable to maintain low imped ance at high frequency Use shielded cables for the signals taken out of the control panel Choose a thick and short cable to ground the FG terminal of the R7D module...

Страница 8: ...d the panel cover with an earth strap grounding may be strengthened and EMC may be improved Ground the control panel at low impedance using e g braided wires Keep the opening for ventilation as small...

Страница 9: ...cautions are illustrated in the next page Keep cables as short as possible It prevents noise emissions from the cables and noise overlapping to the cables Attach a ferrite core to reduce noise impact...

Страница 10: ...pplicable when wiring the R7D Series To external apparatus Keep the cable as short as possible To external apparatus Shielded Cable Earth Clamp Remove a part of the shielded cable cover and ground it...

Отзывы: