TERMINAL CONNECTIONS

Connect the module referring to the connection diagram.

RS-232C

T3

T4

T2

T1

T7

T6

T5

Term.

Resist.

Output

Circuit

When the device is located at the end of a transmission line via twisted-pair cable,

(when there is no cross-wiring), close across the terminal T2 – T3 with the attached 

jumper pin (or with a leadwire).

When the device is not at the end, remove the jumper pin.

*

Power

Circuit

+

Shielded Twisted-pair Cable

To Other

I/O Modules

Jumper

*

FG

U (+)

V (–)

POWER

D-SUB CONNECTOR

9

8

7

6

5

4

3

2

1

10

12

11

13

15

14

16

17

18

20

19

21

22

23

24

25

27

26

28

29

30

31

32

33

35

34

36

ch.A
ch.B

ch.C
ch.D

COM (–)

COM (–)

COUNTER RESET

ch.1
ch.2
ch.3
ch.4
ch.5
ch.6
ch.7
ch.8

COM (–)

ch.1
ch.2
ch.3
ch.4
ch.5
ch.6
ch.7
ch.8

COM (–)

Input Circuit

TOTALIZED

COUNTER

INPUT

CONTACT

INPUT

CONTACT

OUTPUT

DO NOT CONNECT to the terminals 5 thr. 8 or 10 thr. 16.

Wrong connection may cause failure of the device.

ABBR. 

PIN NO.  EXPLANATION OF FUNCTION

BA (SD) 

Transmitted Data 

 

 

BB (RD) 

Received Data   

 

 

AB (SG) 

Signal Common

CB (CS) 

Clear to Send   

 

 

CA (RS) 

Request to Send

 

Not Used. 

 

 

 

 

DO NOT connect.  Connecting may 

 

cause malfunctions. 

 

 

 

9

1

5

6

9

 RS-232C INTERFACE

Содержание R1M-P4

Страница 1: ...NAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below 100 240V AC rating 85 264V 47 66 Hz approx 10VA 24V DC rating 24V 10 approx 7W GENERAL PRECAUTIONS Before you remove the module turn off the power supply and input signal for safety PC RECORDER SOFTWARE Use the latest version of PC Recorder Software included in the product package ENV...

Страница 2: ...SCSI devices may impair appropriate performance MSR128LS MSR128LV MSR128LS MSR128LV PC IBM PC AT or compatible Operating system Microsoft Windows XP SP1 or SP2 For High Speed Mode Group 0 50 msec storing cycle use Windows XP SP1 SP2 Note Proper software functions may not be ensured under certain conditions CPU Pentium II 233 MHz or higher 2 Screen area 800 by 600 pixels or better resolution 640 by...

Страница 3: ...Digital Meter Contact Output LED TOP VIEW BOTTOM VIEW REAR VIEW INSTALLATION DIN RAIL MOUNTING Set the body so that its DIN rail adaptor is at the bottom Pull down the DIN rail adaptor Position the upper hook at the rear side on the DIN rail and push in the lower Push back the DIN rail adaptor WALL MOUNTING Set the body so that its DIN rail adaptor is at the bottom Pull down the DIN rail adaptor R...

Страница 4: ...mper FG U V POWER D SUB CONNECTOR 9 8 7 6 5 4 3 2 1 10 12 11 13 15 14 16 17 18 20 19 21 22 23 24 25 27 26 28 29 30 31 32 33 35 34 36 ch A ch B ch C ch D COM COM COUNTER RESET ch 1 ch 2 ch 3 ch 4 ch 5 ch 6 ch 7 ch 8 COM ch 1 ch 2 ch 3 ch 4 ch 5 ch 6 ch 7 ch 8 COM Input Circuit TOTALIZED COUNTER INPUT CONTACT INPUT CONTACT OUTPUT DO NOT CONNECT to the terminals 5 thr 8 or 10 thr 16 Wrong connection ...

Страница 5: ...STEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE M SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL INCIDENTAL OR SPECIAL DAMAGES OF ANY KIND WHATSOEVER M System Co Ltd 5 2 55 Minamitsumori Nishinari ku Osaka 557 0063 JAPAN Phone 06 6659 8201 Fax 06 6659 8510 E mail info m system co jp EXT...

Отзывы: