manualshive.com logo in svg
background image

R1M-P4

P.  / 5

EM-5665 Rev.9

PC REQUIREMENTS

  (provided by the user)

 MSR128-V6

 

NORMAL MODE (storing rates ≥500 ms) 

HIGH SPEED MODE (storing rates 100 / 200 ms)

PC 

IBM PC/AT or compatible

Operating system 

Microsoft Windows XP SP1, SP2, Windows Vista Business 32 bits, Windows 7 Professional 32 bits  

 

Note: Proper software functions may not be ensured under certain conditions.

CPU 

Pentium III 800 MHz or higher 

Pentium IV 2.0 GHz or higher

Screen area 

1024 by 768 pixels or better resolution

Display color 

65000 colors  (16 bits)

Video memory 

2 MB minimum; 4 MB recommended 

4 MB minimum

Main memory 

256 MB recommended for Windows XP 

512 MB recommended for Windows XP 

 

 

1 GB recommended for Windows Vista, Windows 7  1 GB recommended for Windows Vista, Windows 7

Hard disk area 

Use an internal hard disk. *

1

 

Use an internal hard disk. *

1

 

 

 

 

Max. approx. 100 MB required per day. 

Max. approx. 500 MB required per day.

Printer 

Use a printer for Windows.  The programs use Standard System Fonts used in Windows.  

 

 

Use a printer driver for Standard System Fonts.

CD-ROM drive 

Used when installing the software program.

Card reader drive 

Used with devices which save data in a Compact Flash Card

Communication port  RS-232C port (COM1 through COM5) supported 

LAN card  by Windows 

 

 

 

 

LAN card

*1. External (e.g. SCSI) devices may impair appropriate performance.

 MSR128LS, MSR128LV

 

MSR128LS 

MSR128LV

PC 

IBM PC/AT or compatible

Operating system 

Microsoft Windows XP SP1 or SP2. 

 

 

 

 

 

 

 

For High Speed Mode (Group 0, 50-msec. storing cycle), use Windows XP SP1, SP2. 

 

 

 

Note: Proper software functions may not be ensured under certain conditions.

CPU 

Pentium II 233 MHz or higher *

2

Screen area 

800 by 600 pixels or better resolution 

640 by 480 pixels or better resolution

Display color 

65000 colors  (16 bits)

Main memory 

256 MB for Windows XP

Hard disk area 

200 MB minimum *

3

 

 

 

 

 

 

 

 

Follow the respective OS’s standard for Windows XP.

CD-ROM drive 

Used when installing the software program.

Communication port  RS-232C port (COM1 through COM5) supported by Windows *

4

 or LAN communication card

*2. Alternately, Celeron 300 MHz or higher with the secondary cache

 

For High Speed Mode (Group 0, 50-msec. storing cycle), Pentium III 800 MHz or higher.

*3. External (e.g. SCSI) devices may impair appropriate performance.

*4. The RS-232C port may be predefined for other purposes than for COM port.  

 

Driver software change or system configuration may be required before using such a port.

Note 1: At 50-msec. storing cycle (Group 0), the MSR128LS/LV may not be able to store every bit of data depending upon 

the PC’s performance levels.  These missing data will be substituted by the last stored data.  Only one (1) node is 

connectable in the high speed mode.

Note 2: Please refer to the hardware data sheet for response time of the module.

Содержание R1M-P4

Страница 1: ...NAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below 100 240V AC rating 85 264V 47 66 Hz approx 10VA 24V DC rating 24V 10 approx 7W GENERAL PRECAUTIONS Before you remove the module turn off the power supply and input signal for safety PC RECORDER SOFTWARE Use the latest version of PC Recorder Software included in the product package ENV...

Страница 2: ...SCSI devices may impair appropriate performance MSR128LS MSR128LV MSR128LS MSR128LV PC IBM PC AT or compatible Operating system Microsoft Windows XP SP1 or SP2 For High Speed Mode Group 0 50 msec storing cycle use Windows XP SP1 SP2 Note Proper software functions may not be ensured under certain conditions CPU Pentium II 233 MHz or higher 2 Screen area 800 by 600 pixels or better resolution 640 by...

Страница 3: ...Digital Meter Contact Output LED TOP VIEW BOTTOM VIEW REAR VIEW INSTALLATION DIN RAIL MOUNTING Set the body so that its DIN rail adaptor is at the bottom Pull down the DIN rail adaptor Position the upper hook at the rear side on the DIN rail and push in the lower Push back the DIN rail adaptor WALL MOUNTING Set the body so that its DIN rail adaptor is at the bottom Pull down the DIN rail adaptor R...

Страница 4: ...mper FG U V POWER D SUB CONNECTOR 9 8 7 6 5 4 3 2 1 10 12 11 13 15 14 16 17 18 20 19 21 22 23 24 25 27 26 28 29 30 31 32 33 35 34 36 ch A ch B ch C ch D COM COM COUNTER RESET ch 1 ch 2 ch 3 ch 4 ch 5 ch 6 ch 7 ch 8 COM ch 1 ch 2 ch 3 ch 4 ch 5 ch 6 ch 7 ch 8 COM Input Circuit TOTALIZED COUNTER INPUT CONTACT INPUT CONTACT OUTPUT DO NOT CONNECT to the terminals 5 thr 8 or 10 thr 16 Wrong connection ...

Страница 5: ...STEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE M SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL INCIDENTAL OR SPECIAL DAMAGES OF ANY KIND WHATSOEVER M System Co Ltd 5 2 55 Minamitsumori Nishinari ku Osaka 557 0063 JAPAN Phone 06 6659 8201 Fax 06 6659 8510 E mail info m system co jp EXT...