manualshive.com logo in svg
background image

R1M-P4

P.  / 5

EM-5665 Rev.9

COMPONENT IDENTIFICATION

RS-485

Connector

Address Setting

Rotary SW

Configurator

Jack

Specifications Marking

Power Terminals

RS-232C

9-pin Connector

RUN Indicator

LED

1 2

T1 T2 T3 T4

T5 T6 T7

3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36

1 2 3 4 5 6 7 8

SW602

SW602 is fixed to 

the position 3.

DO NOT CHANGE.

Momentary

SW604

Totalized

(factory default)

Totalized (lower 6 digits) or Momentary Value Display

Totalized or Momentary

Display Selector

Contact Input LED

Channel Selector

for Digital Meter

Contact Output LED

 TOP VIEW

 BOTTOM VIEW

 REAR VIEW

INSTALLATION

 DIN RAIL MOUNTING

Set the body so that its DIN rail 
adaptor  is  at  the  bottom.    Pull 
down the DIN rail adaptor.
Position  the  upper  hook  at  the 
rear  side  on  the  DIN  rail  and 
push in the lower.  Push back the 
DIN rail adaptor.

 WALL MOUNTING

Set the body so that its DIN rail 
adaptor  is  at  the  bottom.    Pull 
down the DIN rail adaptor.
Refer  to  “EXTERNAL  DIMEN-
SIONS.”

DIN Rail Adaptor

DIN Rail

35mm wide

CHECKING

1)  Terminal wiring:  Check that all cables are correctly con-

nected according to the connection diagram.

2)  Power input: Check supply voltage.

ADJUSTMENT PROCEDURE

This  unit  is  calibrated  at  the  factory  to  meet  the  ordered 
specifications,  therefore  you  usually  do  not  need  any  cali-
bration.

Содержание R1M-P4

Страница 1: ...NAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below 100 240V AC rating 85 264V 47 66 Hz approx 10VA 24V DC rating 24V 10 approx 7W GENERAL PRECAUTIONS Before you remove the module turn off the power supply and input signal for safety PC RECORDER SOFTWARE Use the latest version of PC Recorder Software included in the product package ENV...

Страница 2: ...SCSI devices may impair appropriate performance MSR128LS MSR128LV MSR128LS MSR128LV PC IBM PC AT or compatible Operating system Microsoft Windows XP SP1 or SP2 For High Speed Mode Group 0 50 msec storing cycle use Windows XP SP1 SP2 Note Proper software functions may not be ensured under certain conditions CPU Pentium II 233 MHz or higher 2 Screen area 800 by 600 pixels or better resolution 640 by...

Страница 3: ...Digital Meter Contact Output LED TOP VIEW BOTTOM VIEW REAR VIEW INSTALLATION DIN RAIL MOUNTING Set the body so that its DIN rail adaptor is at the bottom Pull down the DIN rail adaptor Position the upper hook at the rear side on the DIN rail and push in the lower Push back the DIN rail adaptor WALL MOUNTING Set the body so that its DIN rail adaptor is at the bottom Pull down the DIN rail adaptor R...

Страница 4: ...mper FG U V POWER D SUB CONNECTOR 9 8 7 6 5 4 3 2 1 10 12 11 13 15 14 16 17 18 20 19 21 22 23 24 25 27 26 28 29 30 31 32 33 35 34 36 ch A ch B ch C ch D COM COM COUNTER RESET ch 1 ch 2 ch 3 ch 4 ch 5 ch 6 ch 7 ch 8 COM ch 1 ch 2 ch 3 ch 4 ch 5 ch 6 ch 7 ch 8 COM Input Circuit TOTALIZED COUNTER INPUT CONTACT INPUT CONTACT OUTPUT DO NOT CONNECT to the terminals 5 thr 8 or 10 thr 16 Wrong connection ...

Страница 5: ...STEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE M SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL INCIDENTAL OR SPECIAL DAMAGES OF ANY KIND WHATSOEVER M System Co Ltd 5 2 55 Minamitsumori Nishinari ku Osaka 557 0063 JAPAN Phone 06 6659 8201 Fax 06 6659 8510 E mail info m system co jp EXT...

Отзывы: