manualshive.com logo in svg
background image

R1M-P4

P.  / 5

EM-5665 Rev.9

PC RECORDER

(4 totalized counter inputs, 8 contact inputs and outputs)

MODEL

R1M-P4

INSTRUCTION MANUAL

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If  you  have  any  problems  or  questions  with  the  product, 
please contact M-System’s Sales Office or representatives.

This product is for use in general industrial environments, 
therefore may not be suitable for applications which require 
higher level of safety (e.g. safety or accident prevention sys-
tems) or of reliability (e.g. vehicle control or combustion con-
trol systems).

For  safety,  installation  and  maintenance  of  this  product 
must be conducted by qualified personnel.

 PACKAGE INCLUDES:

  PC Recorder .................................................................. (1)
  Cable (9-pin D-sub cable, straight type) ...................... (1)
  CD (software and users manual) ................................. (1)

 MODEL NO.

Confirm  Model  No.  marking  on  the  product  to  be  exactly 
what you ordered.

 INSTRUCTION MANUAL

This  manual  describes  necessary  points  of  caution  when 
you use this product, including installation, connection and 
basic maintenance procedures.  Read also the Users Manual 
for the software included in the CD for maximum use of the 
PC Recorder.

POINTS OF CAUTION

 POWER INPUT RATING & OPERATIONAL RANGE

Locate the power input rating marked on the product and 
confirm its operational range as indicated below:
  100 – 240V AC rating: 85 – 264V, 47 – 66 Hz, approx. 10VA
  24V DC rating: 24V ±10%, approx. 7W
 

 GENERAL PRECAUTIONS

Before  you  remove  the  module,  turn  off  the  power  supply 
and input signal for safety.

 PC RECORDER SOFTWARE

Use the latest version of PC Recorder Software included in 
the product package.

 ENVIRONMENT

• Indoor use
• When heavy dust or metal particles are present in the air, 

install  the  module  inside  proper  housing  with  sufficient 
ventilation.

• Do not install the module where it is subjected to continu-

ous vibration.  Do not apply physical impact to the mod-
ule.

• Environmental temperature must be within -5 to +60°C     

(23 to 140°F) with relative humidity within 30 to 90% RH 
in order to ensure adequate life span and operation.

• Be sure that the ventilation slits are not covered with ca-

bles, etc.

 WIRING

• Wrong connection may damage the module.
• Do not connect cables to moving parts or pull them tight-

ly.

• Do  not  install  cables  (power  supply,  input  and  output) 

close  to  noise  sources  (relay  drive  cable,  high  frequency 
line, etc.).

• Do  not  bind  these  cables  together  with  those  in  which 

noises are present.  Do not install them in the same duct.

 AND ....

The module is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for sat-
isfying complete performance described in the data sheet.

Содержание R1M-P4

Страница 1: ...NAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below 100 240V AC rating 85 264V 47 66 Hz approx 10VA 24V DC rating 24V 10 approx 7W GENERAL PRECAUTIONS Before you remove the module turn off the power supply and input signal for safety PC RECORDER SOFTWARE Use the latest version of PC Recorder Software included in the product package ENV...

Страница 2: ...SCSI devices may impair appropriate performance MSR128LS MSR128LV MSR128LS MSR128LV PC IBM PC AT or compatible Operating system Microsoft Windows XP SP1 or SP2 For High Speed Mode Group 0 50 msec storing cycle use Windows XP SP1 SP2 Note Proper software functions may not be ensured under certain conditions CPU Pentium II 233 MHz or higher 2 Screen area 800 by 600 pixels or better resolution 640 by...

Страница 3: ...Digital Meter Contact Output LED TOP VIEW BOTTOM VIEW REAR VIEW INSTALLATION DIN RAIL MOUNTING Set the body so that its DIN rail adaptor is at the bottom Pull down the DIN rail adaptor Position the upper hook at the rear side on the DIN rail and push in the lower Push back the DIN rail adaptor WALL MOUNTING Set the body so that its DIN rail adaptor is at the bottom Pull down the DIN rail adaptor R...

Страница 4: ...mper FG U V POWER D SUB CONNECTOR 9 8 7 6 5 4 3 2 1 10 12 11 13 15 14 16 17 18 20 19 21 22 23 24 25 27 26 28 29 30 31 32 33 35 34 36 ch A ch B ch C ch D COM COM COUNTER RESET ch 1 ch 2 ch 3 ch 4 ch 5 ch 6 ch 7 ch 8 COM ch 1 ch 2 ch 3 ch 4 ch 5 ch 6 ch 7 ch 8 COM Input Circuit TOTALIZED COUNTER INPUT CONTACT INPUT CONTACT OUTPUT DO NOT CONNECT to the terminals 5 thr 8 or 10 thr 16 Wrong connection ...

Страница 5: ...STEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE M SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL INCIDENTAL OR SPECIAL DAMAGES OF ANY KIND WHATSOEVER M System Co Ltd 5 2 55 Minamitsumori Nishinari ku Osaka 557 0063 JAPAN Phone 06 6659 8201 Fax 06 6659 8510 E mail info m system co jp EXT...