background image

R1M-J3

P. 4 / 4

EM-5654 Rev.5

M-SYSTEM WARRANTY

M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such 
product was originally purchased if such product has been used under normal operating conditions and properly maintained, M-System’s sole liability, and purchaser’s exclusive 
remedies, under this warranty are, at M-System’s option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this 
warranty.  To submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original 
sales invoice.
THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED 
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR 
SPECIAL DAMAGES OF ANY KIND WHATSOEVER.
M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: [email protected]

MODBUS WIRING CONNECTION

R1M

T1

T2

T3

T4

R1M

T1

T2

T3

T4

T1

T2

T3

T4

R1M

CONNECTO

R

RS-232C

RS-485

*

1

*

1

*

1. Internal terminating resistor is used when the device is at the end of a transmission line.

*

2. Install shielded cables to all sections and ground them at single point.

*

2

FG

RS-485

TERMINAL CONNECTIONS

Connect the module referring to the connection diagram.

RS-232C

T3

T4

T2

T1

T7

T6

T5

Term.

Resist.

Output

Circuit

When the device is located at the end of a transmission line via twisted-pair cable, (when there is no 

cross-wiring), close across the terminal T2 – T3 with the attached jumper pin (or with a leadwire).

When the device is not at the end, remove the jumper pin.

*

9

8

7

6

5

4

3

2

1

10

12

11

13

15

14

16

17

18

20

19

21

22

23

24

25

27

26

28

29

30

31

32

33

35

34

36

TRIGGER INPUT

+

Power

Circuit

Input

Circuit

+

Shielded Twisted-pair Cable

To Other

I/O Modules

Jumper

*

FG

U (+)

V (–)

POWER

D-SUB CONNECTOR

A
B
B

RTD INPUT

+

3
2
1

POT INPUT

INPUT 1

max.

min.

A
B
B

3
2
1

INPUT 2

A
B
B

3
2
1

INPUT 3

A
B
B

3
2
1

INPUT 4

A
B
B

3
2
1

INPUT 5

A
B
B

3
2
1

INPUT 6

A
B
B

3
2
1

INPUT 7

A
B
B

3
2
1

INPUT 8

Unused

This device is not designed to attenuate noises on input signals, therefore we ecommend that the user 

takes precautions to eliminate noises from the input signals e.g. by using shielded twisted-pair cable.

DO NOT CONNECT to the terminals 25 through 34.  Wrong connection may cause failure of the device.

ABBR. 

PIN NO.  EXPLANATION OF FUNCTION

BA (SD) 

Transmitted Data 

 

 

BB (RD) 

Received Data   

 

 

AB (SG) 

Signal Common

CB (CS) 

Clear to Send   

 

 

CA (RS) 

Request to Send

 

Not Used. 

 

 

 

 

DO NOT connect.  Connecting may 

 

cause malfunctions. 

 

 

 

9

1

5

6

9

 RS-232C INTERFACE

Содержание R1M-J3

Страница 1: ... for the RS 232C cable are recommended The equipment must be installed such that appropriate clearance and creepage distances are maintained to con form to CE requirements The actual installation environments such as panel con figurations connected devices connected wires may af fect the protection level of this unit when it is integrated in a panel system The user may have to review the CE requir...

Страница 2: ...SCSI devices may impair appropriate performance MSR128LS MSR128LV MSR128LS MSR128LV PC IBM PC AT or compatible Operating system Microsoft Windows XP SP1 or SP2 For High Speed Mode Group 0 50 msec storing cycle use Windows XP SP1 SP2 Note Proper software functions may not be ensured under certain conditions CPU Pentium II 233 MHz or higher 2 Screen area 800 by 600 pixels or better resolution 640 by...

Страница 3: ...ions therefore you usually do not need any cali bration MAINTENANCE Regular calibration procedure is explained below CALIBRATION Warm up the unit for at least 10 minutes Apply 0 25 50 75 and 100 input signal Check that the output signal for the respective input signal remains within accu racy described in the data sheet When the output is out of tolerance please contact M System s Sales Office or ...

Страница 4: ...l terminating resistor is used when the device is at the end of a transmission line 2 Install shielded cables to all sections and ground them at single point 2 FG RS 485 TERMINAL CONNECTIONS Connect the module referring to the connection diagram RS 232C T3 T4 T2 T1 T7 T6 T5 Term Resist Output Circuit When the device is located at the end of a transmission line via twisted pair cable when there is ...

Отзывы: