background image

W2XF

P.  / 4

EM-5507

LINEARIZER

MODEL

W2XF

INSTRUCTION MANUAL

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If  you  have  any  problems  or  questions  with  the  product, 
please contact M-System’s Sales Office or representatives.

 PACKAGE INCLUDES:

  Signal conditioner (body + base socket) ...................... (1)

 MODEL NO.

Confirm  Model  No.  marking  on  the  product  to  be  exactly 
what you ordered.

 INSTRUCTION MANUAL

This  manual  describes  necessary  points  of  caution  when 
you use this product, including installation, connection and 
basic maintenance procedures.
The unit is programmable using the PC Configurator Soft-
ware.    For  detailed  information  on  the  PC  configuration, 
refer to the W2CFG users manual.  The W2CFG PC Con-
figurator Software is downloadable at M-System’s web site: 
http://www.m-system.co.jp.

POINTS OF CAUTION

 POWER INPUT RATING & OPERATIONAL RANGE

• Locate the power input rating marked on the product and 

confirm its operational range as indicated below:

  100 – 240V AC rating: 85 – 264V, 47 – 66 Hz, approx. 5 – 7VA
  24V DC rating: 24V ±10%, approx. 3W

 GENERAL PRECAUTIONS

• Before you remove the unit from its base socket or mount 

it, turn off the power supply and input signal for safety.

 ENVIRONMENT

• Indoor use
• When heavy dust or metal particles are present in the air, 

install the unit inside proper housing with sufficient ven-
tilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -5 to +55°C     

(23 to 131°F) with relative humidity within 30 to 90% RH 
in order to ensure adequate life span and operation.

• Be sure that the ventilation slits are not covered with ca-

bles, etc.

 WIRING

• Do  not  install  cables  (power  supply,  input  and  output) 

close  to  noise  sources  (relay  drive  cable,  high  frequency 
line, etc.).

• Do  not  bind  these  cables  together  with  those  in  which 

noises are present.  Do not install them in the same duct.

 AND ....

• The unit is designed to function as soon as power is sup-

plied, however, a warm up for 20 minutes is required for 
satisfying  complete  performance  described  in  the  data 
sheet.

• With  voltage  output,  do  not  leave  the  output  terminals 

shortcircuited  for  an  extended  time  period.   The  unit  is 
designed to endure it without breakdown, however, it may 
shorten appropriate life duration.

COMPONENT IDENTIFICATION

Fixing Screw

Connection
Diagram

Specifications

Body

Base Socket

Rugghölzli 2
CH - 5453 Busslingen

Tel. +41 (0)56 222 38 18

Fax +41 (0)56 222 10 12

[email protected]

www.sentronic.com

Produkte, Support und Service

SENTRONIC

AG

Содержание Mini-MW Series

Страница 1: ...nt Z1 Range 0 20 mA DC Voltage V2 Range 10 10 V DC V3 Range 5 5 V DC 3 OUTPUT 2 Same range availability as Output 1 Y None Configurator software is used to change output over the described range of the selected suffix code For changing between suffix codes set the Output Range Selector on the side of unit before software adjustment 4 POWER INPUT AC Power M2 100 240 V AC Operational voltage range 8...

Страница 2: ...r range can be any specific value within the output range provided that the minimum span is maintained Load resistance Output drive 12 V max for Output 1 7 V max for Output 2 e g 4 20 mA 600 Ω 12 V 20 mA If not specified the output range is 4 20 mA DC DC Voltage Code V2 wide spans Operational range 11 5 11 5 V DC Minimum span 1 V Code V3 narrow spans Operational range 6 6 V DC Minimum span 0 5 V O...

Страница 3: ...onfiguration DIP SW OFF ON 1 2 3 4 OFF ON 1 2 3 4 Provided only for two output type Refer to the instruction manual for detailed procedures EXTERNAL DIMENSIONS TERMINAL ASSIGNMENTS unit mm inch 4 8 7 10 23 91 89 3 50 84 3 31 10 39 22 87 59 2 32 DIN RAIL 35mm wide 4 16 11 M3 SCREW 72 2 83 29 5 1 16 53 2 09 2 4 2x5 17x 20 MTG HOLE 6 24 deep 114 4 49 11 5 6 1 2 3 9 6 23 When mounting no extra space i...

Страница 4: ...enclosed by broken line is only with 2nd output option DIP SW DIP SW Digital Computation Low Drift Amplifier STATUS CONFIGURATOR JACK CURRENT Z1 VOLTAGE S1 S2 24 9Ω Specifications are subject to change without notice Rugghölzli 2 CH 5453 Busslingen Tel 41 0 56 222 38 18 Fax 41 0 56 222 10 12 mailbox sentronic com www sentronic com Produkte Support und Service SENTRONICAG ...

Страница 5: ...pply and input signal for safety ENVIRONMENT Indoor use When heavy dust or metal particles are present in the air install the unit inside proper housing with sufficient ven tilation Do not install the unit where it is subjected to continuous vibration Do not subject the unit to physical impact Environmental temperature must be within 5 to 55 C 23 to 131 F with relative humidity within 30 to 90 RH ...

Страница 6: ...cted according to the connection diagram 2 Check DIP switch setting 3 Power input voltage Check voltage across the terminal 10 11 with a multimeter 4 Input Check that the input signal is within 0 100 of the full scale 5 Output Check that the load resistance meets the de scribed specifications 6 LED Confirm that the LEDs indicate the normal oper ating mode DIN Rail 35mm wide Spring Loaded DIN Rail ...

Страница 7: ...ee front LEDs LD1 LD2 LD3 indicate the transmitter s operating status by different flashing pat terns Examples are shown below LD1 LD2 LD3 A LD1 LD2 LD3 G LD1 LD2 LD3 R NORMAL OPERATION RUN MODE ERROR MODE Parameter Error Error occurred when reading parameters from the internal memory LD1 LD2 LD3 A A G Overrange Input The input is below 15 or above 115 G G A PC Configuration RUN Mode The transmitt...

Страница 8: ...11 M3 SCREW 72 2 83 29 5 1 16 53 2 09 2 4 2x5 17x 20 MTG HOLE 6 24 deep 114 4 49 11 5 6 1 2 3 9 6 23 When mounting no extra space is needed between units 4 16 Rugghölzli 2 CH 5453 Busslingen Tel 41 0 56 222 38 18 Fax 41 0 56 222 10 12 mailbox sentronic com www sentronic com Produkte Support und Service SENTRONICAG ...