EM-5095  Rev.3  P. 3 / 4

WIRING INSTRUCTIONS

 

SCREW TERMINAL

Torque: 0.8 N·m

 

SOLDERLESS TERMINAL

Refer to the drawing below for recommended ring tongue 
terminal size.  Spade tongue type is also applicable.
Applicable wire size: 0.25 to 1.65 mm

2

 (AWG 22 to 16)

Recommended manufacturer: Japan Solderless Terminal 
MFG.Co.Ltd, Nichifu Co.,ltd

6 (.24) max

3.3 (.13) max

mm (inch)

CHECKING

1) Terminal wiring:  Check that all cables are correctly con-

nected according to the connection diagram.

2) Power input voltage:  Check voltage across the terminal 

10 – 11 with a multimeter.

3) Switching command contact:  Confirm adequate opera-

tions of the contact signal.

LIGHTNING SURGE PROTECTION

M-System offers a series of lightning surge protector for 
protection against induced lightning surges.  Please contact 
M-System to choose appropriate models.

Содержание Mini-M M2MNV

Страница 1: ...vel of this unit when it is integrated in a panel system The user may have to review the CE requirements in regard to the whole system and employ additional protective measures to ensure the CE conform ity Install lightning surge protectors for those wires connect ed to remote locations POWER INPUT RATING OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operati...

Страница 2: ...ng a minus screwdriver and pull WALL MOUNTING Refer to EXTERNAL DIMENSIONS TERMINAL CONNECTIONS Connect the unit as in the diagram below or refer to the connection diagram on the side of the unit EXTERNAL DIMENSIONS unit mm inch 4 8 7 10 11 5 6 1 2 3 9 22 87 6 24 59 2 32 11 M3 SCREW 72 2 83 29 5 1 16 2 4 2x5 17x 20 MTG HOLE 6 24 deep When mounting no extra space is needed between units 21 5 85 70 ...

Страница 3: ...G 22 to 16 Recommended manufacturer Japan Solderless Terminal MFG Co Ltd Nichifu Co ltd 6 24 max 3 3 13 max mm inch CHECKING 1 Terminal wiring Check that all cables are correctly con nected according to the connection diagram 2 Power input voltage Check voltage across the terminal 10 11 with a multimeter 3 Switching command contact Confirm adequate opera tions of the contact signal LIGHTNING SURGE...

Страница 4: ...r ON Switching command OFF to ON or Power ON Switching command ON to OFF Current Signal receiving resistor 50 Ω Voltage Signal 1 Resistor is provided only for the input code 2 Current signal receiving resistor 50 Ω 1 Resistor is provided only for the input code 2 Current signal receiving resistor 50 Ω 1 1 1 1 1 2 4 5 7 8 1 2 4 5 7 8 1 1 1 1 Switching Status When the switching command contact is sw...

Отзывы: