manualshive.com logo in svg
background image

M6DXU

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-7853  Rev.3  P. 3 / 5

 

CONNECTION DIAGRAM

4

7

8

3

1

2

5

6

OUTPUT

POWER

+

U (+)

V (–)

JACK

3

2

1

max.

min.

A

B

A

A

B

B

A

B

B

CONFIGURATOR

+

2-wire

3-wire

4-wire

RTD

T/C

DC

POT.

+

+

+

Current Input (Z1)

Voltage Input (S1, S2)

+

comp. leadwire

Available only for DC power input type

POWER

*

CONNECTOR

 

WIRING INSTRUCTIONS

  • Applicable wire size

     

Solid: 0.2 to 2.5 mm

2

 (0.55 to 1.75 dia.)

     

Stranded: 0.2 to 2.5 mm

2

 (Tinning wire ends may 

     

 

 

     cause contact failure and therefore is not 

     

 

 

     recommended.)

     

Ferruled: 0.2 to 1.5 mm

2

 (0.55 to 1.35 dia.)

  • Expose wire conductors by 8 mm (0.31”).

8 mm

8 mm

3.7 mm dia.

max.

3.7 mm dia.

max.

Wire exposure

Recommended
ferruled wire

• How to Connect Wires

Screwdriver

Wire

Insert a wire.  Confirm that the wire tip hits the bottom and 
tighten the screw with a screwdriver.
Confirm that the wire’s insulation tube is not caught in the 
terminal. (Torque: 0.3 N·m)

Screwdriver

Wire

8 mm

6 mm

Отзывы: