EM-8428  Rev.9  P. 1 / 13

INSTRUCTION MANUAL

L

ON

W

ORKS

 INTERFACE MODULE

(I/O 56 points)

MODEL

R3-NL2

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If you have any problems or questions with the product, 
please contact M-System’s Sales Office or representatives.

 

PACKAGE INCLUDES:

Network interface module ..................................................(1)
Neuron ID label ...................................................................(2)

 

MODEL NO.

Confirm Model No. marking on the product to be exactly 
what you ordered.

 

INSTRUCTION MANUAL

This manual describes necessary points of caution when 
you use this product, including installation, connection and 
basic maintenance procedures.

POINTS OF CAUTION

 

HOT SWAPPABLE MODULES

• The module can be replaced while the power is ON.  Be 

sure to replace it when the module is not communicat-
ing with a host, as it may affect the system.  Replacing 
multiple modules at once may greatly change line voltage 
levels.  We highly recommend to replace them one by one.

 

POWER INPUT RATING & OPERATIONAL RANGE

• Locate the power input rating marked on the product and 

confirm its operational range as indicated below:

  100 – 120V AC rating: 85 – 132V, 47 – 66 Hz, approx. 20VA
  200 – 240V AC rating: 170 – 264V, 47 – 66 Hz, approx. 20VA
    24V DC rating: 24V ±10%, approx. 12W

 

GENERAL PRECAUTIONS

• DO NOT set the switches while the power is supplied.  

The switches are used only for maintenance without the 
power.

 

ENVIRONMENT

• Indoor use.
• When heavy dust or metal particles are present in the 

air, install the unit inside proper housing with sufficient 
ventilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -10 to +55°C 

(14 to 131°F) with relative humidity within 30 to 90% RH 
in order to ensure adequate life span and operation.

 

WIRING

• Do not install cables close to noise sources (relay drive 

cable, high frequency line, etc.).

• Do not bind these cables together with those in which 

noises are present.  Do not install them in the same duct.

 

AND ....

• The unit is designed to function as soon as power is sup-

plied, however, a warm up for 10 minutes is required for 
satisfying complete performance described in the data 
sheet.

INSTALLATION

Use the Installation Base Model R3-BS, or Model R3-BSW 
for free I/O address capability.
Before mounting the Network Interface Module onto the 
base, be sure to configure the module as explained below.

 

DATA ALLOCATION

The setting determines the data area size assigned to each 
I/O module mounted on the base.

 

NETWORK SLOTS ON THE BASE

I/O 1

I/O 2

I/O n

With Model R3-BS base, mount the I/O Modules from the 
left end (I/O 1) to the right in order that the Network Mod-
ule assigns data areas from I/O 1.
Network Module(s) and Power Module are mounted basi-
cally at the right end though technically they could be 
mounted in any position.

With Model R3-BSW base, there is no limitation in mount-
ing positions as I/O address can be assigned freely to each 
module using rotary switches equipped on the base.

Содержание LONWORKS R3-NL2

Страница 1: ...for maintenance without the power ENVIRONMENT Indoor use When heavy dust or metal particles are present in the air install the unit inside proper housing with sufficient ventilation Do not install th...

Страница 2: ...identify the node in LONWORKS network configura tion RESET SW Used to reset the Neuron Chip Press the switch to reset Control functions are halted while completing resetting and restarting Confirm no...

Страница 3: ...6 2 24 CONNECTION DIAGRAM INTERNAL POWER INTERNAL BUS LONWORKS CONFIGURATION JACK JACK BUS CONNECTOR 1 1 2 3 4 5 4 RUN RUN RUN CONTACT OUTPUT 2 3 6 U V FG POWER INPUT Not provided with No Power Suppl...

Страница 4: ...NAL BLOCKS INPUT OUTPUT 56 0 SNVT_temp R3NL2_TI56_103 XIF R3NL2_TI56_103 APB NodeObject NL2TIn 56 0 SNVT_temp_p R3NL2_TPI56_103 XIF R3NL2_TPI56_103 APB NodeObject NL2TPIn DISCRETE INPUT OUTPUT NO of D...

Страница 5: ...SNVT_obj_request NVO 1 nvoStatus SNVT_obj_status NVO 2 nvoCardState SNVT_state NVO 3 nvoCardErr SNVT_state Number of internal communication errors NVO 4 nvoCommErr SNVT_count NVO 5 nvoFileDirectory SN...

Страница 6: ...OG I O FUNCTIONAL BLOCKS NL2LVIn NVO 6 nvoLV01 SNVT_lev_percent 56 variables NVO 61 nvoLV56 SNVT_lev_percent NL2LVOut NVI 6 nviLV01 SNVT_lev_percent 56 variables NVI 61 nviLV56 SNVT_lev_percent NL2LVI...

Страница 7: ...hone 81 6 6659 8201 Fax 81 6 6659 8510 E mail info m system co jp EM 8428 Rev 9 P 7 13 TEMPERATURE INPUT FUNCTIONAL BLOCKS NL2TIn NVO 6 nvoT01 SNVT_temp 56 variables NVO 61 nvoT56 SNVT_temp NL2TPIn NV...

Страница 8: ...8 Rev 9 P 8 13 DISCRETE I O FUNCTIONAL BLOCKS NL2SWIn NVO 6 nvoSW01 SNVT_switch 56 variables NVO 61 nvoSW56 SNVT_switch NL2SWOut NVI 6 nviSW01 SNVT_switch 56 variables NVI 61 nviSW56 SNVT_switch NL2SW...

Страница 9: ...8428 Rev 9 P 9 13 TOTALIZED PULSE I O FUNCTIONAL BLOCKS NL2CIn NVO 6 nvoC01 SNVT_count 56 variables NVO 61 nvoC56 SNVT_count NL2COut NVI 6 nviC01 SNVT_count 56 variables NVI 61 nviC56 SNVT_count NL2C...

Страница 10: ...co jp EM 8428 Rev 9 P 10 13 TOTALIZED PULSE INPUT DISCRETE I O FUNCTIONAL BLOCKS NL2CISWIO NVO 24 nvoC01 SNVT_count 16 variables NVO 39 nvoC16 SNVT_count NVO 40 nvoSW01 SNVT_switch 16 variables NVO 5...

Страница 11: ...ched 65535 nvoCardStatus SNVT_state 0 or 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Indicates that I O modules are mounted in each slot Bit 0 through bit 15 are applied for slot 1 through 16 0 Not mounted 1 Mo...

Страница 12: ...es nviDoState SNVT_state For factory adjustment Do not use nvoDiState SNVT_state For factory adjustment Do not use TRANSMISSION DATA ASSIGNMENTS ANALOG INPUT OUTPUT The DIP SW located at the side of t...

Страница 13: ...LV09 through nviLV16 Module 7 R3 YV8S 8 nviLV17 through nviLV24 Module 8 R3 NL2 N Module 9 R3 PS3 R TOTALIZED PULSE INPUT DISCRETE I O Network Variables for the discrete input channels are assigned fi...

Отзывы: