background image

R3-NL2

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-8428  Rev.9  P. 2 / 13

COMPONENT IDENTIFICATION

RUN LED

FRONT VIEW

SIDE VIEW

ERR LED

1

2

3

4

5

6

ONLINE LED

SERVICE SW

SERVICE LED

RESET SW

Configuration Jack

1

2

3

4

5

SW2

ON

8

7

6

5

4

3

2

1

SW3

ON

4

3

2

1

ON

8

7

6

5

4

3

2

1

SW1

DIP SW

Euro Type
Connector Terminal

 

STATUS INDICATOR LED

RUN indicator:

 Bi-color (green/red) LED; Green ON in com-

munications with another device on-line or 
changing the output data (turns off after 25 
seconds of no communication)

ERR indicator:

 Bi-color (green/red) LED; Green ON in nor-

mal status; Green blinks when the APB file 
is not adequately imported; Green/Orange 
ON in turn in an abnormality.

ONLINE indicator:

 Red LED

 ON:

 

Off-line or no network information (decom-
missioned)

 

Blinking in approx. 0.5 Hz:

 On-line (ready to communi-

cate network variables)

 

Blinking in approx. 5 Hz for 12 sec.:

 Wink message re-

ceived

SERVICE indicator:

 Green LED

 OFF:

 

Normal operations

 

Blinking in approx. 0.5 Hz:

 No network information

 ON:

 

Internal program error

 

SERVICE SW

Used to identify the node in L

ON

W

ORKS

 network configura-

tion.

 

RESET SW

Used to reset the Neuron Chip.  Press the switch to reset.
Control functions are halted while completing resetting and 
restarting.  Confirm no danger before conducting resetting.

 

SIDE DIP SW

(*) Factory setting.

• Data Allocation: SW1, SW2

Data Allocation Type* must be assigned to each I/O module 
position to specify how many data areas (four types) are to 
be occupied by each.
Two bits from SW1 and SW2 are assigned to each posi-
tion, and data areas can be specified from the module No. 1 
through 8.  Setting for No. 9 and later modules is identical 
to No. 8.

SW ASSIGNMENT

MODULE NO.

SW1-1

SW1-2

1

SW1-3

SW1-4

2

SW1-5

SW1-6

3

SW1-7

SW1-8

4

SW2-1

SW2-2

5

SW2-3

SW2-4

6

SW2-5

SW2-6

7

SW2-7

SW2-8

8

SW SETTING

DATA ALLOCATION

OFF

OFF

1

ON

OFF

4

OFF

ON

8

ON

ON

16

*  Refer to the specifications of the related series for the Data 

Allocation Type of I/O modules.

• Input Error Data: SW3-2

Hold

: When the communication from an input module is lost 

due to the input module error, the network module holds the 
signal and stands by until the communication recovers.

Set to ‘0’

: When the communication from an input module 

is lost due to the input module error, the network module 
outputs ‘0.’

SW

INPUT ERROR DATA

HOLD (

*

)

SET ‘0’

SW3-2

OFF

ON

Note: Be sure to set unused SW3-1, 3-3 and 3-4 to OFF.

Содержание LONWORKS R3-NL2

Страница 1: ...for maintenance without the power ENVIRONMENT Indoor use When heavy dust or metal particles are present in the air install the unit inside proper housing with sufficient ventilation Do not install th...

Страница 2: ...identify the node in LONWORKS network configura tion RESET SW Used to reset the Neuron Chip Press the switch to reset Control functions are halted while completing resetting and restarting Confirm no...

Страница 3: ...6 2 24 CONNECTION DIAGRAM INTERNAL POWER INTERNAL BUS LONWORKS CONFIGURATION JACK JACK BUS CONNECTOR 1 1 2 3 4 5 4 RUN RUN RUN CONTACT OUTPUT 2 3 6 U V FG POWER INPUT Not provided with No Power Suppl...

Страница 4: ...NAL BLOCKS INPUT OUTPUT 56 0 SNVT_temp R3NL2_TI56_103 XIF R3NL2_TI56_103 APB NodeObject NL2TIn 56 0 SNVT_temp_p R3NL2_TPI56_103 XIF R3NL2_TPI56_103 APB NodeObject NL2TPIn DISCRETE INPUT OUTPUT NO of D...

Страница 5: ...SNVT_obj_request NVO 1 nvoStatus SNVT_obj_status NVO 2 nvoCardState SNVT_state NVO 3 nvoCardErr SNVT_state Number of internal communication errors NVO 4 nvoCommErr SNVT_count NVO 5 nvoFileDirectory SN...

Страница 6: ...OG I O FUNCTIONAL BLOCKS NL2LVIn NVO 6 nvoLV01 SNVT_lev_percent 56 variables NVO 61 nvoLV56 SNVT_lev_percent NL2LVOut NVI 6 nviLV01 SNVT_lev_percent 56 variables NVI 61 nviLV56 SNVT_lev_percent NL2LVI...

Страница 7: ...hone 81 6 6659 8201 Fax 81 6 6659 8510 E mail info m system co jp EM 8428 Rev 9 P 7 13 TEMPERATURE INPUT FUNCTIONAL BLOCKS NL2TIn NVO 6 nvoT01 SNVT_temp 56 variables NVO 61 nvoT56 SNVT_temp NL2TPIn NV...

Страница 8: ...8 Rev 9 P 8 13 DISCRETE I O FUNCTIONAL BLOCKS NL2SWIn NVO 6 nvoSW01 SNVT_switch 56 variables NVO 61 nvoSW56 SNVT_switch NL2SWOut NVI 6 nviSW01 SNVT_switch 56 variables NVI 61 nviSW56 SNVT_switch NL2SW...

Страница 9: ...8428 Rev 9 P 9 13 TOTALIZED PULSE I O FUNCTIONAL BLOCKS NL2CIn NVO 6 nvoC01 SNVT_count 56 variables NVO 61 nvoC56 SNVT_count NL2COut NVI 6 nviC01 SNVT_count 56 variables NVI 61 nviC56 SNVT_count NL2C...

Страница 10: ...co jp EM 8428 Rev 9 P 10 13 TOTALIZED PULSE INPUT DISCRETE I O FUNCTIONAL BLOCKS NL2CISWIO NVO 24 nvoC01 SNVT_count 16 variables NVO 39 nvoC16 SNVT_count NVO 40 nvoSW01 SNVT_switch 16 variables NVO 5...

Страница 11: ...ched 65535 nvoCardStatus SNVT_state 0 or 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Indicates that I O modules are mounted in each slot Bit 0 through bit 15 are applied for slot 1 through 16 0 Not mounted 1 Mo...

Страница 12: ...es nviDoState SNVT_state For factory adjustment Do not use nvoDiState SNVT_state For factory adjustment Do not use TRANSMISSION DATA ASSIGNMENTS ANALOG INPUT OUTPUT The DIP SW located at the side of t...

Страница 13: ...LV09 through nviLV16 Module 7 R3 YV8S 8 nviLV17 through nviLV24 Module 8 R3 NL2 N Module 9 R3 PS3 R TOTALIZED PULSE INPUT DISCRETE I O Network Variables for the discrete input channels are assigned fi...

Отзывы: