9.4.1 DATA DISPLAY
The Retrieve view can show 8 pens at the maximum. Four (4) pages (display groups) are available.
Last part of the stored data is indicated first. If you are using the 73VR21x only for plotting on the screen without
recording, naturally no retrieval is available.
The screen time frame in the Retrieve chart depends upon the storing rate. Table below shows the screen time frame
by display types at various storing rate settings.
CHART TYPE
STORING INTERVAL
Perpendicular
with digital display
Perpendicular
without digital display
Horizontal
100 msec.
13.7 seconds
21.7 seconds
29.7 seconds
500 msec.
1 min., 8.5 seconds
1 min., 48.5 seconds
2 min., 28.5 seconds
1 second
2 min., 17 seconds
3 min., 37 seconds
4 min., 57 seconds
2 seconds
4 min., 34 seconds
7 min., 14 seconds
9 min., 54 seconds
5 seconds
11 min., 25 seconds
18 min., 5 seconds
24 min., 45 seconds
10 seconds
22 min., 50 seconds
36 min., 10 seconds
49 min., 30 seconds
1 minute
2 hours, 17 min.
3 hours, 37 min.
4 hours, 57 min.
10 minutes
22 hours, 50 min.
1 day, 12 hours, 10 min.
2 days, 1 hour, 30 min.
The chart can be scrolled using your finger. Touch the screen with your finger and move up and down. The chart
area shifts accordingly.
The digital meters shows values at the time point indicated with the red line on the screen. The red line moves to
where your finger touches. Touch Hide button to remove the digital display.
Data read-out cursor
Figure: Data read-out.
Comments written in during recording is also indicated on the screen.
Figure: Comment written in the record.
Error Data Indication
When an input (or function data) is in error, it waveform is no plotted on the screen. ‘ERR’ is indicated on the digital
display. For a 2-byte integer function data, ‘0’ is indicated on the digital display.