 POWER INPUT

• Power  input  rating  &  operational  range:  Check  the  power  rating  for  the  unit  on  the 

specification label.

     Rating 100 – 240V AC:  85 – 264V, 47 – 66 Hz, 
   

 

 

 

approx. 25VA at 100V, approx. 35VA at 240V

     Rating 24V DC:   

24V ±10%, approx. 11W

• Supplying any level of power other than specified above can damage the 73VR21x or 

the power source.

• The power cables and the signal I/O cables for the 73VR21x must be located separately.
• The main circuit cables (high voltage and high current), the signal I/O cables, and the 

power cables should not be bundled together or placed near each other.

• To increase noise resistance of the power input wires, twist the strands before connecting.

 SAFETY PRECAUTION

• Before you remove the unit, turn off the power supply and input signal for safety.
• Do not use the 73VR21x in an environment where flammable gases are present.  This 

may result in an explosion.

• Do not disassemble or modify the 73VR21x in any way.  Doing so may result in a fire 

or an electrical shock.

• Do not strike the panel of the 73VR21x with a hard, heavy or pointed object, or press 

the panel with excessive force, it may result in panel damage or injury.

• Do not block the 73VR21x’s ventilation openings or use it in areas where heat accumu

-

lates.  Additionally, do not store or use it under high-temperature conditions.

• Do not store or use the 73VR21x in locations subject to direct sunlight, or where exces

-

sive dust or dirt is present.

• The 73VR21x is a precision instrument.  Do not store or use it where large shocks or 

excessive vibration can occur.

• Do  not  store  or  use  the  73VR21x  in  environments  subject  to  chemical  evaporation 

(such as that of organic solvents), or where there are chemicals and/or acids present in 
the air.

• Do not use paint thinner or organic solvents to clean the 73VR21x.
• Observe the environmental conditions when using the 73VR21x.
• Wait at least for 5 seconds before turning on the power supply after it has been turned 

off.  The 73VR21x may not start up if the time interval is less than 5 seconds.

 ENVIRONMENT

• Indoor use
• The 73VR21x is designed to be mounted on a vertical panel.  It is not suitable for a 

slanted or a horizontal panel surface.

• Environmental temperature must be within 0 to 50°C (32 to 122°F) with relative humid

-

ity within 30 to 85% RH in order to ensure adequate life span and operation.

• Desktop type cannot be mounted on a panel surface.
• The handle and rubber feet cannot be detached from desktop type unit.

Содержание 73VR2102

Страница 1: ...Read Before Installation Contents 1 POINTS OF CAUTION 2 2 PACKAGE INCLUDES 7 3 ITEMS TO PREPARE 8 4 COMPONENT IDENTIFICATION 9 5 EXTERNAL DIMENSIONS 11 6 INSTALLING THE UNIT 13 7 PREPARATION WIRING T...

Страница 2: ...quirements The equipment must be mounted on a panel surface Once mounted on a panel take appropriate precautions to prevent operators to be exposed to the terminal block In order to enable the operato...

Страница 3: ...e force it may result in panel damage or injury Do not block the 73VR21x s ventilation openings or use it in areas where heat accumu lates Additionally do not store or use it under high temperature co...

Страница 4: ...The following phenomena are LCD characteristics and NOT a product defect LCD screen may show uneven brightness depending upon displayed images or con trast settings The LCD screen pixels may contain m...

Страница 5: ...mostly safe from these interferences however the measuring accuracies for other input types may be compromised by large common mode noise As described in the data sheet the DC AC voltage across the C...

Страница 6: ...mocouple inputs No parallel connection is permitted for RTD DO NOT APPLY OVERRANGE NORMAL MODE VOLTAGE Do not apply voltages exceeding 20V to terminals B C for 3V 6V or 12V ranges to prevent damage Fo...

Страница 7: ...Please confirm that all items mentioned below are included in the package Paperless Recorder Cold junction compensationn sensor attached to the terminals Software CD 73VRPAC2 Startup guide this bookl...

Страница 8: ...name CFC III Model No AP CFxxxxE3ER ETNDNRK Parts No 256 MB 81 2A010 1H34C 512 MB 81 2B010 1H34C 1 GB 81 2E010 1H34C Model No AP CFxxxxE3ER ETNDNR Parts No 256 MB 81 2A010 1H10C 512 MB 81 2B010 1H10C...

Страница 9: ...h Panel Screen FRONT VIEW 1 Touch Panel Screen Trend chart and other data views and setup views are displayed 2 Front Cover Access to the CF Card Slot 3 CF Card Slot Insert a CF Card 4 Eject Button Us...

Страница 10: ...4C 6A 6B 6C 1A 1B 1C 3A 3B 3C 5A 5B 5C 2A 2B 2C 4A 4B 4C 6A 6B 6C FG ALM ALM U V TRG TRG 7A 7B 7C 9A 9B 9C 11A11B11C 8A 8B 8C 10A10B10C12A12B12C 8 Maintenance Jack FG ALM ALM U V TRG TRG 12 Power Inpu...

Страница 11: ...IONS Unit mm inch 144 5 67 172 6 77 29 5 1 16 2 to 26 panel thickness 08 to 1 02 Attach the mounting bracket either on the top bottom or on the sides 151 5 5 96 144 5 67 136 5 5 37 151 5 5 96 136 5 5...

Страница 12: ...73VR2104 73VR2106 73VR2108 73VR2110 73VR2112 12 144 5 67 172 6 77 29 5 1 16 144 5 67 136 5 5 37 136 5 5 37 The handle and rubber feet cannot be detached from desktop type unit 25 98 173 6 81 4 16 Desk...

Страница 13: ...Attach the mounting bracket either on the top bottom or on the sides 144 5 67 151 5 5 96 144 5 67 151 5 5 96 195 7 68 29 5 1 16 2 to 26 panel thickness 08 to 1 02 136 5 5 37 136 5 5 37 73VR2108 73VR21...

Страница 14: ...73VR2104 73VR2106 73VR2108 73VR2110 73VR2112 14 144 5 67 144 5 67 195 7 68 29 5 1 16 136 5 5 37 136 5 5 37 173 6 81 4 16 Desktop type 25 98 The handle and rubber feet cannot be detached from desktop t...

Страница 15: ...2 to 26 mm Material Steel PANEL CUTOUT Unit mm 137 2 0 137 2 0 137 2 0 SINGLE MOUNTING VERTICAL CLUSTERED MOUNTING max 3 units HORIZONTAL CLUSTERED MOUNTING L 2 0 137 2 0 175 min L 2 0 L mm Number 2 3...

Страница 16: ...brackets either on the sides or on the top and bottom of the unit Tighten screws CAUTION Adequate tightening torque for the screws used to mount the unit onto the panel is be tween 0 8 and 1 2 N m If...

Страница 17: ...F Card Out 1 When the 73VR21x is recording data touch MENU key on the right bottom on the screen and touch Stop to stop the recording 2 Push EJECT button to the right side of the card slot and take th...

Страница 18: ...3 Wire power cable and protective grounding cable to the power terminal 4 Close the terminal cover CONNECTING INPUT SIGNALS The following explanation is an example with a thermocouple connected to Inp...

Страница 19: ...the setting details 1 Insert the CF card into the 73VR21x Turn on the power supply to the 73VR21x NOTES Creating Files in the CF Card The 73VR21x creates files necessary to function once the power is...

Страница 20: ...k setup Return Go to the previous view page Go to Help view Next Go to the next view page 6 Storing interval view is on the screen Touch Storing interval key to show available options Choose 1 sec and...

Страница 21: ...3VR2112 21 9 Tag view is on the screen Touch Next 10 Default tag names are on the screen Touch these names to change Leave the default INPUT01 as it is in this exam ple Touch Next NOTES Pens you disab...

Страница 22: ...ge Touch the current unit selection for Input 1 and a keypanel appears on the screen The following is an example to set C for Input 1 1 Touch key for three 3 times to choose 2 Touch A a key once to sw...

Страница 23: ...ons to change Touch the current type selection for Input 1 and a list of available options will appear Choose K CA and the screen automatically returns to Analog type view Touch Next 15 Input range vi...

Страница 24: ...uch Next 18 Default scaling ranges are on the screen Touch these values to change The scaling range is fixed for a temperature input Touch Next 19 Now the basic setting is complete Touch Record NOTES...

Страница 25: ...list of functions Touch Start to start recording In order to show real time data on the screen Trend view Bargraph view and Over view are available Trend View Bargraph View Overiew In order to show pa...

Отзывы: