53U

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-6485-A  Rev.15  P. 5 / 8

TERMINAL CONNECTIONS

For UL approved model, L and N are marked instead of U(+) and V (–). 

DO/PO

+ –

DI

+ –

T1 T2T3 T4

V1 V2 V3 N 1S 1L 2S 2L 3S 3L

U

(+)

V

(–)

CONFIG

V1 N V2 1S 1L 2S 2L

L1

source

load

N

L2

u

v

v

u

U

V

V

U

k

l

K

L k

l

K

L

V1 N V2 1S 1L 2S 2L

L1

source

load

N

L2

k

l

K

L k

l

K

L

V1 N V2 1S 1L 2S 2L

L1

source

load

N

L2

V1 V2 V3 1S 1L

L1

source

load

L2
L3

u

v

v

u

U

V

V

U

k

l

K

L

V1 V2 V3 1S 1L

L1

source

load

L2
L3

V1 V2 V3 1S 1L 3S 3L

L1

source

load

L2
L3

u

v

v

u

U

V

V

U

k

l

K

L k

l

K

L

V1 V2 V3 1S 1L 3S 3L

L1

source

load

L2
L3

k

l

K

L k

l

K

L

V1 V2 V3 1S 1L 3S 3L

L1

source

load

 L2

L3

k

l

K

L

V1 V2 V3 1S 1L

L1

source

load

L2
L3

V1 N

1S 1L

L1

source

load

N

k

l

K

L

u

v

U

V

V1 N

1S 1L

L1

source

load

N

k

l

K

L

V1 N

1S 1L

L1

source

load

N

System / 
Application

Single phase /
2-wire

Three phase /
3-wire,
balanced load

Single phase /
3-wire

Terminal

1S 1L

3S 3L

L1

source

load

L2
L3

k

l

V1

u v

U V

V2

u v

U V

V3

u v

U V

N

K

L

k

l

K

L

V1

V2

V3

1S 1L

3S 3L

N

L1

source

load

L2
L3

k

l

K

L

k

l

K

L

2S 2L

k

l

K

L

V1

V2

V3

1S 1L

3S 3L

N

2S 2L

L1

source

load

L2
L3

N

N

N

2S 2L

k

l

K

L

V1 N

1S 1L

L1

source

load

L2

k

l

K

L

u

v

U

V

V1 N

1S 1L

L1

source

load

L2
L3

N

k

l

K

L

V1 N

1S 1L

L1

source

load

L2

L3

L3

N

N

System / 
Application

Three phase /
4-wire,
balanced load

Three phase /
3-wire,
unbalanced load

Three phase /
4-wire,
unbalanced load

Terminal

Configurator Jack 

External Interface

 

Input

Auxiliary Power 

Supply

Note: For low voltage circuit, grounding is not required.

Содержание 53U

Страница 1: ...VES OR UL This equipment is suitable for Pollution Degree 2 Meas urement Category III input transient voltage 6000V and Installation Category II auxiliary power transient voltage 2500V And insulation...

Страница 2: ...age 0 3 0 2 for Option H Current 0 3 0 2 for Option H Power 0 5 Power factor 0 5 Frequency 0 1 Energy 1 0 5 for Option H Harmonic contents 1 Analog out put Accuracy of assigned measurand or 0 2 whiche...

Страница 3: ...AX E PRG PF THD ENTER ESCAPE E PRG ESCAPE E PRG ESCAPE IU PQS PF THD Hold down IU Hold down Hold down Hold down Hold down Hold down NORMAL MODE Indicates values Indicates Voltage or Current Indicates...

Страница 4: ...0 5 to 3 5 mm2 Stripped length 7 to 8 mm Contact input contact output analog output Modbus auxiliary power Applicable cable size 2 4 mm dia 0 5 to 2 5 mm2 Stripped length 7 to 8 mm CONNECTING TO POWE...

Страница 5: ...1S 1L 3S 3L L1 source load L2 L3 k l K L V1 V2 V3 1S 1L L1 source load L2 L3 V1 N 1S 1L L1 source load N k l K L u v U V V1 N 1S 1L L1 source load N k l K L V1 N 1S 1L L1 source load N System Applica...

Страница 6: ...gurator cable is left connected 3 For UL approved model L and N are marked instead of U and V To other Modbus devices EXTERNAL INTERFACE CODE 8 V U DO PO DO PO DI DI CONTACT INPUT CONTACT OUTPUT AO2 A...

Страница 7: ...d ground them at single point 2 FG RS 485 SYSTEM CONFIGURATION EXAMPLES RS 485 Modbus RTU Multi Power Monitor model 53U RS 232 C RS 232 C RS 485 Converter model R2K 1 or LK1 Lightning Surge Protector...

Страница 8: ...D74R or MDP 4R 1 AX IN AX IN AX IN Lightning Surge Protector for RS 485 422 model MD74R or MDP 4R 1 1 Insert lightning surge protectors recommended in this example if necessary ETHERNET RUN SEND FIELD...

Отзывы: