53U

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-6485-A  Rev.15  P. 6 / 8

T3
T4

T2

T1

Term.

Resist.

+

Shielded Twisted-pair Cable

Jumper 

*

1

V(–)

JACK

U(+)

DO/PO–

DO/PO+

DO/PO–

DO/PO+

DI –

DI +

CONTACT 

INPUT

CONTACT 

OUTPUT

• Contact Input Connection E.g.

+

-

• Contact Output Connection E.g.

+

-

DI +

DI –

To other 

Modbus devices

 EXTERNAL INTERFACE CODE: 1

T3
T4

T2

T1

+

Shielded Twisted-pair Cable

Jumper 

*

1

V(–)

JACK

U(+)

DO/PO COM

DO/PO3+

DO/PO2+

DO/PO1+

*

1. When the device is located at the end of a transmission line via 

      twisted-pair cable, (when there is no cross-wiring), close across the 

      terminal T2 – T3 with a leadwire.

      When the device is not at the end, no shortcircuit wire is required.

*

2. Analog output may momentarily fluctuate while the configurator cable 

      is left connected.

*

3. For UL approved model, L and N are marked, instead of U(+) and V(–).

To other 

Modbus devices

 EXTERNAL INTERFACE CODE: 8

V(–)

U(+)

DO/PO–

DO/PO+

DI –

DI +

CONTACT 

INPUT

CONTACT 

OUTPUT

AO2 –

AO2 +

AO1 –

AO1 +

ANALOG 

OUTPUT 1

ANALOG 

OUTPUT 2

 EXTERNAL INTERFACE CODE: 4, 5

V(–)

U(+)

DO/PO1–

DO/PO1+

CONTACT 

OUTPUT 1

DO/PO2–

DO/PO2+

CONTACT 

OUTPUT 2

AO2 –

AO2 +

AO1 –

AO1 +

ANALOG 

OUTPUT 1

ANALOG 

OUTPUT 2

 EXTERNAL INTERFACE CODE: 6, 7

V(–)

U(+)

CONTACT OUTPUT 3

CONTACT OUTPUT 2

CONTACT OUTPUT 1

DO/PO3–

DO/PO3+

CONTACT 

OUTPUT 3

DO/PO4–

DO/PO4+

CONTACT 

OUTPUT 4

DO/PO1–

DO/PO1+

CONTACT 

OUTPUT 1

DO/PO2–

DO/PO2+

CONTACT 

OUTPUT 2

 EXTERNAL INTERFACE CODE: 9

V(–)

U(+)

AO4 –

AO4 +

AO3 –

AO3 +

ANALOG 

OUTPUT 3

ANALOG 

OUTPUT 4

AO2 –

AO2 +

AO1 –

AO1 +

ANALOG 

OUTPUT 1

ANALOG 

OUTPUT 2

 EXTERNAL INTERFACE CODE: 2, 3

CONFIGURATOR

CONFIGURATOR 

*

2

JACK

CONFIGURATOR 

*

2

JACK

CONFIGURATOR

JACK

CONFIGURATOR 

*

2

CONFIGURATOR

JACK

*

3

*

3

*

3

*

3

*

3

*

3

AUXILIARY POWER

AUXILIARY POWER

AUXILIARY POWER

AUXILIARY POWER

AUXILIARY POWER

AUXILIARY POWER

Term.

Resist.

Содержание 53U

Страница 1: ...VES OR UL This equipment is suitable for Pollution Degree 2 Meas urement Category III input transient voltage 6000V and Installation Category II auxiliary power transient voltage 2500V And insulation...

Страница 2: ...age 0 3 0 2 for Option H Current 0 3 0 2 for Option H Power 0 5 Power factor 0 5 Frequency 0 1 Energy 1 0 5 for Option H Harmonic contents 1 Analog out put Accuracy of assigned measurand or 0 2 whiche...

Страница 3: ...AX E PRG PF THD ENTER ESCAPE E PRG ESCAPE E PRG ESCAPE IU PQS PF THD Hold down IU Hold down Hold down Hold down Hold down Hold down NORMAL MODE Indicates values Indicates Voltage or Current Indicates...

Страница 4: ...0 5 to 3 5 mm2 Stripped length 7 to 8 mm Contact input contact output analog output Modbus auxiliary power Applicable cable size 2 4 mm dia 0 5 to 2 5 mm2 Stripped length 7 to 8 mm CONNECTING TO POWE...

Страница 5: ...1S 1L 3S 3L L1 source load L2 L3 k l K L V1 V2 V3 1S 1L L1 source load L2 L3 V1 N 1S 1L L1 source load N k l K L u v U V V1 N 1S 1L L1 source load N k l K L V1 N 1S 1L L1 source load N System Applica...

Страница 6: ...gurator cable is left connected 3 For UL approved model L and N are marked instead of U and V To other Modbus devices EXTERNAL INTERFACE CODE 8 V U DO PO DO PO DI DI CONTACT INPUT CONTACT OUTPUT AO2 A...

Страница 7: ...d ground them at single point 2 FG RS 485 SYSTEM CONFIGURATION EXAMPLES RS 485 Modbus RTU Multi Power Monitor model 53U RS 232 C RS 232 C RS 485 Converter model R2K 1 or LK1 Lightning Surge Protector...

Страница 8: ...D74R or MDP 4R 1 AX IN AX IN AX IN Lightning Surge Protector for RS 485 422 model MD74R or MDP 4R 1 1 Insert lightning surge protectors recommended in this example if necessary ETHERNET RUN SEND FIELD...

Отзывы: