Oil Lubricated Ball-Bearings
Preparation of bearing housing
Bearing frame must be carefully cleaned before filling with oil.
It is also good practice to flush it with oil, compatible with the lubricating oil that will be used.
The reservoir is to be filled to appropriate level as illustrated in the picture below.
The oil level must be maintained at the correct level: decreasing of oil level may cause overheating and failure of
the bearings, while exceeding the correct level can result in leakage. The constant level oiler can be adjusted by
changing the height of the cross arms which support the glass reservoir, as illustrated for TRICO oiler below.