INSTRUCTION FOR INSTALLATION AND USE LUNA GOLD+ WOOD
REFERENTIAL DISTANCES IN REGARDS TO FINISHING THE MANTLEPIECE
A very essential point when setting up the Luna Gold is that the distance has to be respected
inbetween fireplace and the finishing material for the mantlepiece such as marble, gipsum,...
For this, a small bended metal sheet that is provided ont the fireplace ( pic.1 ) , is to be used as the
minimal reference for the distance. The finishing can only ga oas far as this meteal sheet ( pic.2 ).
Don’t remove this ( pic.3 ) ! This allows you to take out the 4th side frame and to let the airflow in
the mantlepiece for natural convection.
2.3
INSULATION AND FINISHING
Once installation is complete, the appliance can be fitted. Once you have checked everything, you
can perform the final insulating and finishing operations.
The built-in part of the furnace tends to be very warm. Please check that the furnace is not too
narrowly fitted and that there is adequate space for the elimination of hot air. For insulation of the
furnace, we advise you to use M Design insulating plates. You are advised against using any other
insulation product. Inflammable materials as well may not be used for the finishing.
Please , follow this instruction. The appliance can overheat if you not apply those in
-
structions.
Pic. 2
Pic. 3
min. 5 mm
The masonry must be raised around the furnace. Because of the expansion
of the furnace during combustion, an interstice of at least 5 mm must be
provided on each side of the appliance. The masonry must not lean against
the furnace.
THE APPLIANCE MUST BE SET FREE .
Please pay attention to leave approx. 2 mm inbetween the finishing frame
and maconry ( see p.17 , mounting a 3-sided frame )
Pic. 1
7