INSTRUCTION FOR INSTALLATION AND USE LUNA GOLD+  WOOD

Tabel N°1. Warm air outlet

with fan

without fan

Luna Gold 700 H 

2

2

Luna Gold 850 H

2

2

Luna Gold 1000H

2

4

  Luna Gold 1150 H

  2

  4

  Luna Gold 1300 H

  2 

  4

  Luna Gold 550 V 

  2

  2 

  Luna Gold 850 V

  2

  4

  Luna Gold 1000V / 1150V   2

  4

  Luna Gold 850 DV / DH

  

  2

  Luna Gold 1150 DH

  2

  Luna Gold 1000DV

  

  2

2.6 CONVECTION CURRENT

   

2.6.1 Natural convection

It is compulsory to open 2 or 4 hot air vents (see table 1) at the 

top of the appliance. The entrance for the air supply convection are situated 

at the lower backside of the Luna Gold+ and also through the opening that is 

provided for the fan. These have been constructed in such a way that no air can 

be blown out along here, not even with a fan. The stove is placed at least 20 mm 

above the floor (if placed on the floor) to allow for natural convection.

A clearance of at least 4 dm3  , excluding the measurements of a dust filter, or at 

least 6 dm3 , including the measurements of a filter, must be provided for in the 

masonry. (Note: Remember to take the measurements of the clearance of the

grids into account.) (Pic.7a)

    

2.6.2 Convection by means of a fan (optional)

It is compulsory to open at least 2 hot air vents (see table 1). It is essential to 

separate the air supply ducts and the air vents correctly in the masonry. Some 

insulation material gets damaged in time, and it is essential to separate it from 

the ventilation air supply, otherwise one runs the risk that it is sucked in and 

spread in the house. It is therefore also advisable to use fixed insulation plates 

(Promatec, HT-platen or promatec). The fan may be mounted either on the out

-

side or on the inside, which even makes it possible to install a fan afterwards.

    

2.6.3 Hot air ducts

Thermally insulated ducts are essential for the optimal functioning of the ap-

pliance (these cause ‘draught’ in the convection air current). By using the maxi

-

mum number of ducts (at least 2), the output is improved and the noise (that is 

caused by the displacement) is reduced.

For the purposes of the installation of these ducts it is best to go vertically up-

wards first for at least 1m and then to change direction, making a rather wide 

bend and avoid using a flue terminal grid with a small clearance because the 

speed loss that this causes reduces the efficiency of the hot air vents. 

M-design has developed its ideal hot air grids which have many advantages 

(Pic 7b and 7c)

Pic. 7b 

Entrance convection

air ( at backside )

Pic. 7a 

10

Содержание Luna Gold+

Страница 1: ...INSTRUCTION FOR INSTALLATION AND USE LUNA GOLD WOOD LUNA GOLD COLLECTION INSTRUCTION FOR INSTALLATION AND USE Passion for fire English 08 2011 ...

Страница 2: ...I N S T R U C T I O N S F O R T H E M D E S I G N G A S F I R E P L A C E S T H E S U P P L I E R TA K E S N O R E S P O N S B I L I T Y F O R A N Y P O S S I B L E D A M A G E P O O R W O R K I N G A P P L I A N C E S A N D A C C I D E N T A S A R E S U LT O F I N C O R R E C T I N S TA L L AT I O N ...

Страница 3: ...n 2 6 2 Convection generated by a fan optional 2 6 3 Hot air ducts 2 7 FAN 12 2 7 1 Installation 2 7 2 Fan dimmer 2 8 FLUE 13 2 8 1 Flue 2 9 HOW TO REGULATE FIREPLACE IN SENSE OF DROUGHT 14 2 9 1 Baffle plate 2 9 1 1 First settng 14 2 9 1 2 Second setting 15 2 9 2 System with three deflectors 16 2 9 3 Secondary air flow for combustion 17 2 10 BAFFLE PLATE LUNA GOLD SEE TROUGH 18 3 FUNCTIONNING 19 ...

Страница 4: ...the stove output clear glass etc Good quality wood is wood that has been dried under an aerated shelter for at least 2 years 18 moisture content Damp wood gives off less heat and dirties the stove and the chimney less You can also use briquettes the effect is comparable with that of wood and it is best to use them in combination with wood because burning only briquettes makes the temperature too h...

Страница 5: ...arden and that give off smoke and a smell which starts after the fire has burned for about 10 minutes and lasts for about 15 minutes See to it that there is ample ventilation in the room CAUTION It is not necessary to overload the fireplace with wood 1 kg dry wood gives a 4 kW power Example a fireplace with a 78 return gives a power for about 4kw x 78 3 kW for 1 kg dry wood If you want a power of ...

Страница 6: ...ms and conditions of our contract of guarantee Ask your supplier for advice pic 1 pic 2 pic 3 A min 3 5 cm B 14 5 cm C min 18 cm 2 2 POSITIONING THE FIREPLACE Place the fireplace on a stable surface using the adjustable feet Adjust the height of the fireplace by turning the bolt pic 1 The stove may not be placed direct ont the floor to allow natural convection The appertures for the air supply IN ...

Страница 7: ...hing you can perform the final insulating and finishing operations The built in part of the furnace tends to be very warm Please check that the furnace is not too narrowly fitted and that there is adequate space for the elimination of hot air For insulation of the furnace we advise you to use M Design insulating plates You are advised against using any other insulation product Inflammable material...

Страница 8: ...Y ATTENTION TO LEAVE APPROX 2 MM INBETWEEN THE FRAME AND THE FINISHING MATERIAL HEAT EXPANSION pic 1 pic 2 pic 3 8 Example Finished size of the Luna 1150H Gold is 450 x 1080 mm Thickness 3 sided frame 3mm Calculate as follow 1080mm 2x3mm 3 sided frame 2x2mm expansion 1090 mm This is now the measurement you need to have when using a 3 sided frame in combination with marble gyproc or othet materials...

Страница 9: ...o one of the 4 entrances that are provided on the left right or lower side of the fireplace pic 4 5 Use for this purpose one of five connection pieces pic 6 7 Thanks to this new system the air that is required for combustion is completely separated from the convection air stream in the room see further at point 2 3 Convection current The appliance is always delivered with an open air inleet at the...

Страница 10: ...f a fan optional It is compulsory to open at least 2 hot air vents see table 1 It is essential to separate the air supply ducts and the air vents correctly in the masonry Some insulation material gets damaged in time and it is essential to separate it from the ventilation air supply otherwise one runs the risk that it is sucked in and spread in the house It is therefore also advisable to use fixed...

Страница 11: ...LD WOOD EACH APPERTURE YOU MAKE MUST BE CONNECTED WITH FLEXIBLE Design Grid outlet with 2 connections Inlet Grid convection air Inlet Grid convection air Design Grid outlet with 2 connections 2 dm 4 dm Design Grid outlet with 4 connections OR OR ...

Страница 12: ...hat some grids give off more heat than others and seeing that a hot air pipe func tions in a manner similar to a chimney the one that is hot first has the most draught and therefore becomes hot even more quickly 2 7 FAN 2 7 1 Installation Remove the Chamotflex plates the bottom plates and the opening to the fan See pic 8 Now slide the fan downwards to just under the stove Make the necessary electr...

Страница 13: ... and its position are very important One individual flue does not have more than two changes of direction The angle of the corner of these changes of direction may not be greater than 45 with the perpendicular The existing obstacles in the vicinity of the opening into the flue must be taken into account Do not connect more than one stove to a chimney flue Table N 2 MINIMUM HEIGHT OF THE FLUE IN TE...

Страница 14: ...aught The baffle plate is automatically opened when the window is slid open so that no smoke escapes into the living room The plate may be adjusted in 2 ways 2 9 1 1 FIRST SETTING ANGLE BAFFLE PLATE WITH CLOSED DOOR Setting the inclination a of the trottle when the door is closed fig 9a Screw in or screw out the screw spindle nr 2 When necessary completely remove the nut nr 3 and don t forget to p...

Страница 15: ... screws to adjust the moving plate nr 1 fig 9e in sence of drough FIG 9e IMPORTANT IF YOU THINK THE DROUGHT IS NOT ENOUGH AND YOU HAVE SOME SMOKE RETURN IN THE LIVINGROOM THEN YOU HAVE TO CHECK FIRST POINTS 2 9 1 1 AND 2 9 1 2 THIS IS IMPORTANT BEFORE YOU DO ANY OTHER REGULATION 15 ...

Страница 16: ...into the livingroom Fig 10 door closed Fig 11 door open 2cm valve on second deflector main valve Installing the deflectors The first deflector 1 exists of two parts A movable part 1a and a fix part 1b Plate 1a leans on plate 1b Plate 1b has some trenches see picture 13 and 14 The minimal opening to remove the gaz is about 2cm along the width of the first deflector fig 11 When there is to less drau...

Страница 17: ...e window is regulated automatically with two bimetallic strips At each of the superior corners of the window you ll find two circular magnets Those ensures that the window is closing well against the bimetals situated on the main frame of the applliance When the aplliance is still in cold situation the gap between the window and the main frame is made in that way the fire gets enough oxygen When t...

Страница 18: ...r open with the result that the fire will keep burning much more mildly When there is a fire with two lift doors open both the plates will automatically open up completely and therefore there will be no more smoke in the living room When there is a fire with both lift door closed both plates will also close and therefore partly close off the smoke flue tube This will cause the temperature in the s...

Страница 19: ...air coming into the fireplace Pic 9 When the door is opened the air clapet is also being opened Extra air is going in the fire place trough apertures situated in the 4th side frame direct from the air channels see arrows into the fireplace on pic 8 Of course air is also taken from the livingroom The primary air supply can be regulated manually Use the key pic 10 11 to slide the regulator to the le...

Страница 20: ...ave your chimney swept at least once a year for optimal functioning of the Luna Not only is this a legal requirement but it is also meant for your own safety A fire brick Chamotte can still work perfectly even if it is cracked but if pieces are missing the brick must be replaced to effectively protect the combustion chamber Remove the remainder of the ash in time take the ash pan and remove a grea...

Страница 21: ...alfunctions linked to Incorrect installation of incorrect connection Chimney draught that has not been adjusted Transport and installation Incorrect usage Insufficient maintenance Unsuitable hazardous and damp fuel Every internal adjustment to or reconstruction of the stove Burning at extremely high temperature more than 12 kw Costs for packaging and transport All costs not pre arranged with M des...

Страница 22: ...INSTRUCTION FOR INSTALLATION AND USE LUNA GOLD WOOD 6 SPARE PARTS ...

Страница 23: ...INSTRUCTION FOR INSTALLATION AND USE LUNA GOLD WOOD 7 3 SIDED FRAME ...

Страница 24: ...INSTRUCTION FOR INSTALLATION AND USE LUNA GOLD WOOD 8 4th sided Frame ...

Отзывы: