12
*Required dimensions for roof cap - Minimizes static pressure and maximizes air flow to ensure optimum
performance of your Sedona by Lynx™ product.
ROOF CAP DRAWING
12” Open
12”
16”
11”
10”
10”
24”
10”-14”
8”-12”
24” x 24” flashing
DETAIL A
SCALE 1:6
9 7/8” x 2” collar
A