background image

         P VD 5600 Reference Manual. Rev 2.0 

 

Page 32 of 34 

Specifications 

 

Video Input

 

Signal Type 

Serial digital video SMPTE 292M, 344M, 259M-C  

Input standards 

HDTV 1080i 59.94Hz / 60Hz / 50Hz / 
           720P 59.94Hz / 60Hz / 50Hz 
SDTV   525 59.94Hz / 625 50Hz.  
( Field upgradeable for additional format support in future ) 

Connector BNC 

Impedance 75 

Ohm 

Cable Equalization 

Up to 250m Belden 8281 (270MHz) 
Up to 140m Belden 1694A (1.485GHz) 

Return Loss 

> 15 dB (270MHz) 
> 10dB (1.485GHz) 

Reference Input

 

Signal Type 

Analog Bi-level / Tri-level (auto detect) cross lock compatible 

No of inputs 

1 x External or internal rack reference (selectable) 
(PVD 5610 DW provides a loop out of reference) 

Connection BNC 

Impedance 75 

Ohm 

Video Outputs

 

Signal Type 

Serial digital video SMPTE 292M, 344M, 259M-C  

Output standards 

1080i 59.94Hz / 60Hz / 50Hz 
720P 59.94Hz / 60Hz / 50Hz   
525 59.94Hz / 625 50Hz.  

No. Of outputs 

2 separate outputs with 2 x SDI out of each output (4 total)  
(mapped to any internal signal channel) 

Connector BNC 

Impedance 

75 Ohms  

Jitter 

< 0.2 ui (270MHz) < 0.25 ui (1.485GHz) 

Return Loss 

> 15 dB (1.5GHz) 

Video Processing

 

Delay adjustment range 

Up to 5 frames of programmable delay in pixel / line / frame increments. Independent for the 2 
outputs 

Minimum delay 

1 Frame ( including up/down/cross conversion options) 

Video adjustments 

Gain / Saturation / Hue / Black Level 

Aperture correction 

Horizontal only, adjustable for each output channel (3) 

Color space conversion 

601 > 709 or 709 > 601 or transparent (selectable) 

Note.

 Requires conversion option(s) 

Operating Modes

 

Frame Sync 

Basic SD / HD Multi-rate Frame Synchronizer  

Down / ARC 
conv frame 
sync 

Requires Firmware option for Down Conversion 

Control

 

Local Controls 

Local alphanumeric display with integrated menu system for setting “basic” module 
parameters.  

Remote Control 

Comprehensive remote control and status monitoring supported when used with a LYNX 
Controller option. 

The use of the control system is mandated for this module

 

External GPI 

Single GPI input on BNC connector. (Function configurable)  

Electrical Specifications

 

Operating Voltage 

12 VDC 

Power Consumption 

10 W 

Safety 

IEC 60950/ EN 60950/ VDE 0805 

Содержание P VD 5600

Страница 1: ...rm or by any means electronic or mechanical for any purpose without express written permission of LYNX Technik AG LYNX Technik AG may have patents patent applications trademarks copyrights or other in...

Страница 2: ...SDTV Aspect Ratio Conversion 11 Conversion from 16 9 Input Aspect Ratio to 4 3 Output Aspect Ratio 11 4 3 Letterbox 11 4 3 Center Cut 11 4 3 Stretch to Fill 11 Conversion from 4 3 Input Aspect Ratio t...

Страница 3: ...eo Converter 25 Down Converter Mode 25 SDTV Aspect Ratio Converter Mode 25 16 9 to 4 3 conversion 25 4 3 to 16 9 conversion 25 Output Proc Tabs 26 Color Space Conversion 26 Aperture Correction 26 H an...

Страница 4: ...ranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care LYNX Technik shall not be obligated to furnish service under this warranty a...

Страница 5: ...t is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful...

Страница 6: ...static bag unless observing adequate ESD precautions Please see below ESD Warning This product is static sensitive Please use caution and use preventative measures to prevent static discharge or damag...

Страница 7: ...94Hz 720P 60Hz 720P 50Hz Output Video Formats The module provides four SDI outputs user assignable in two sets of two outputs these sets can be mapped independently to any of the internal channels Su...

Страница 8: ...cted Bi level or Tri level Input Format Output 525 59 94Hz 525 59 94Hz 1080i 59 94Hz 1080i 59 94Hz 720P 59 94Hz 720P 59 94Hz With a 50Hz Reference Signal Connected Bi level or Tri level Input Format O...

Страница 9: ...signals are shown below SDTV Analog Bi Level Sync HDTV Analog Tri Level Sync 525 59 94Hz 1080i 59 94Hz 625 50Hz 1080i 60Hz 1080i 50Hz 720P 59 94Hz 720P 60Hz 720P 50Hz Frame Synchronization The algorit...

Страница 10: ...pendent down converter and this will convert the connected HD input standard into a SDTV output signal Modes supported are as follows 4 3 Letterbox This takes the 16 9 aspect ratio of the input HD sig...

Страница 11: ...are as follows Conversion from 16 9 Input Aspect Ratio to 4 3 Output Aspect Ratio 4 3 Letterbox This takes the 16 9 aspect ratio of the input signal and fits it into the 4 3 SD aspect ratio screen wit...

Страница 12: ...io screen 16 9 Stretch to Fill This mode takes the 4 4 input signal and distorts horizontally stretches the image to fit the available 16 9 SD aspect ratio space Color Space Conversion The Conversion...

Страница 13: ...h output The Test pattern will follow the selected output standard selected for each channel The selected test pattern is also available as one of the modes the synchronizer will switch to when excess...

Страница 14: ...e 14 of 34 NOTE Some functions are not shown or are shown as not implemented yet These features will be added at a later date The module is fully programmable so these features can be easily added to...

Страница 15: ...2 0 Page 15 of 34 Module Layout Module Front Panel Module Rear Termination Panel CardModule Layout Note Cooling fan operation is monitored and alarmed with the module alarm LED and also within the LY...

Страница 16: ...in the rack Up to five P VD 5600 modules can be accommodated in a single Series 5000 rack frame NOTE When using this module we highly recommend the use of the R FR 5011 Fan Front Rack Frame which pro...

Страница 17: ...onnection plate 6 Power up the rack and check the module LED s and matrix display illuminate Check the module is automatically logged into the control system device tree It may take a few seconds for...

Страница 18: ...ol provided Some basic module settings are possible via the local controls which are detailed below Once set all settings are automatically saved in non volatile internal memory Flash RAM The module w...

Страница 19: ...system The order of the available settings for any menu item in the table supplied does not represent the order the settings will actually be displayed If left unattended the menu will default to the...

Страница 20: ...Red Flashing Cooling Fan Failure Note The Alarm LED can be seen with the rack front cover fitted LED Color Indication Green Reference Present Yellow Reference Present but not used Module is set to fr...

Страница 21: ...The following GUI screenshots and descriptions shown below describe the settings and adjustments possible for the PVD 5600 CardModule The above screenshot shows the complete module GUI The Device inf...

Страница 22: ...t replicates module block functions and signal flow from left to right The primary purpose of this screen is to show the overall signal flow through the module and allow easy navigation to other areas...

Страница 23: ...on closes the connection operation is self explanatory Test Patterns In each of the two output channels it s possible to switch the test pattern on from the main tab if required Also selectable from t...

Страница 24: ...ible for the synchronizer to configure the output frame rate based upon the connected reference This is the default setting for the module Possible settings are 50Hz 59 94Hz 60Hz Follow last reference...

Страница 25: ...rately these are entered into the module to activate the options Option licenses are managed entered using the Options Tab in the GUI Note Currently the option only supports down conversion the up cro...

Страница 26: ...space so there is the possibility of some illegal colors being reproduced if the color space is not converted Possible selections are Convert convert the video signal Bypass perform no conversion Lum...

Страница 27: ...Time ns Depending on preferences you can use one or all of the adjustments provided to set the total video delay Note The adjustable delay applied is in addition to the fixed one frame processing dela...

Страница 28: ...ing this selection is possible to configure the test pattern into any of the supported standards or it can be set to follow the last input standard Settings provided are Follow last input default SDTV...

Страница 29: ...s purchased with options pre installed then you will see the option status as green Active If you would like to purchase this option after delivery then you will need to purchase the license codes fro...

Страница 30: ...ecord one side of the event For example you might want to log when a SDI input was removed but do not want to log when it came back The ON OFF trigger can be configured for each of the available event...

Страница 31: ...figure what events you would like to transmit a SNMP trap for over the network This has no impact or influence over the internally error log maintained by the LYNX control system Internal LYNX error l...

Страница 32: ...onnector BNC Impedance 75 Ohms Jitter 0 2 ui 270MHz 0 25 ui 1 485GHz Return Loss 15 dB 1 5GHz Video Processing Delay adjustment range Up to 5 frames of programmable delay in pixel line frame increment...

Страница 33: ...e 33 of 34 Mechanical Size 283mm x 78mm Weight CardModule 120g connector plate 50g Rack space Requires 2 slots in rack frame max 5 modules per frame Ambient Temperature 5 C to 40 C Maintaining specifi...

Страница 34: ...available from our website Please do not return products to LYNX without an RMA Please contact your authorized dealer or reseller for more details More detailed product information and product update...

Отзывы: