50
DSX
In the next graphics, it’s shown an adjustment example for the Mid and High ways in a real equipment using
the transductors measures.
First it’s shown only the measure of the natural
response of the speakers in his box and with their
corresponding Amplifier. Only the
Speaker Data
option is active. Be seen as the high driver
sensitivity is roughly 10dB higher and presents a
a small fall on 12Khz.
Mid and high natural response
PEQ + XOVER + Gains Response
Mid and High electroacoustic response
Total electroacoustic response
4 - EDITING WITH DSX
Finally, you will activate the
ADD button
.
The two ways sum response is
the one in black colour.
If now you Include/activate the speaker
response you will see the
total
electroacoustic response
exactly as it
appears on the right screen.
Working on measures and according to
them, high frequencies can be reduced
10 dBs from the
Gains
screen. Mids are
cut at 200 Hz below and 2kHz above with
4ºorder 24 dB/oct Linkwitz-Riley filters
and Highs at 2000 Hz with 4º order 24
dB/oct Linkwitz-Riley. Subsequently, the
equalization of each output is corrected
from the
PEQs
whereas you still view
Final Response
to observe the changes.
The electric processor response will be the shown
in the figure:
PEQ + Xover + Gains response
.