background image

Reference Manual D VD 5002 Version1.1

 

 

Page 11  

 

 

Installation 

 

Caution 

The CardModule is shipped in a 

protective anti-static bag. Please take 
suitable precautions to avoid static 

discharge onto any part of the PCB or 

components when handling module or 
serious damage could result. 

 

Each Card Module is supplied with a rear 
connection panel and two mounting screws. 

Please follow the following procedure for 

installation of the card module into the Series 5000 
Card Frame. 

 

a)

 

Select a slot in the card frame where the 
CardModule will be located 

b)

 

Remove the blank connection panel from the 

rear of the rack (if fitted) 

c)

 

Install the rear connection panel using the 

screws supplied. Do not tighten the screws fully 

d)

 

Slide the card module into the card frame and 
carefully check the CardModule easily 

connects to the rear connection plate. The 
card should fit easily and should not require 

excessive force to insert, if you feel any 

resistance, there could be something wrong 
with the rear connection panel location. Do not 

try and force the connection. Remove the rear 

connection panel and check alignment with 

the CardModule. 

e)

 

Insert and remove the CardModule a few times 

to ensure correct alignment and then tighten 
the two screws to secure the rear connection 

plate 

 

 

Содержание D VD 5002

Страница 1: ...Series 5000 LYNX Technik AG Brunnenweg 3 D 64331 Weiterstadt Germany www lynx technik com Reference Manual D VD 5002 Dual SDI Distribution Amplifier with Monitoring CardModule Version 1 1 ...

Страница 2: ... written permission of LYNX Technik AG LYNX Technik AG may have patents patent applications trademarks copyrights or other intellectual property rights covering the subject matter in this document Except as expressly written by LYNX Technik AG the furnishing of this document does not give you any license to patents trademarks copyrights or other intellectual property of LYNX Technik AG or any of i...

Страница 3: ...rranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care LYNX Technik shall not be obligated to furnish service under this warranty a to repair damage resulting from attempts by personnel other than LYNX Technik representatives to install repair or service the product b to repair damage resulting from improper use or connection to...

Страница 4: ... is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at hi...

Страница 5: ...iption 7 Functional Diagram 8 Module Layout 8 Connections 10 Video Connections 10 Installation 11 Settings and Control 12 Switch Settings 13 Switch Function Detail 13 Factory Preset Condition 14 Auto Store 15 Alarm LED Status Indicators 16 Channel Condition Indicators 16 Alarm Indicator 16 Locate Function 17 Specifications D VD 5002 18 Available Options 19 Parts List 19 Service 20 Contact Informat...

Страница 6: ...Reference Manual D VD 5002 Version1 1 Page 6 This page is intentionally left blank ...

Страница 7: ...clocked or non reclocked and even split between reclocked and non reclocked outputs within the same module Auto detection of standard digital video bit rates in reclocked mode 143Mbit s 177Mbit s 270Mbit s 360Mbit s 540Mbit s and will transparently pass data from 10Mbits s to 640Mbits s in non reclocked mode The analog CVBS monitoring outputs are switched off for bit rates different to 270 MBit s ...

Страница 8: ...the basic functional diagram for the D VD 5002 CardModule Figure 1 D VD 5002 Functional Diagram Module Layout Figure 2 shows the layout of the D VD 5002 CardModule and the rear connection panel Please refer the connections section of this manual for wiring details for the connectors ...

Страница 9: ...Reference Manual D VD 5002 Version1 1 Page 9 Figure 2 Module Layout Caution Use static precautions when handling the PCB Static discharge could result in serious damage to the module ...

Страница 10: ...e of high quality video cable for digital video connections to reduce the risk of interference or errors due to excessive cable attenuation Some guidelines for max cable length are shown below 250m 820 feet Belden 8281 270Mbits s 150m 492 feet Belden 8281 540Mbits s Note Due to the compact design of the connection plate it will be necessary to use a connection tool to secure the BNC video connecto...

Страница 11: ...e located b Remove the blank connection panel from the rear of the rack if fitted c Install the rear connection panel using the screws supplied Do not tighten the screws fully d Slide the card module into the card frame and carefully check the CardModule easily connects to the rear connection plate The card should fit easily and should not require excessive force to insert if you feel any resistan...

Страница 12: ... module to be configured and controlled locally via the dip switch or from remote when using one of the optional controllers and control software Once set all settings are automatically saved in non volatile internal memory Flash ram The module will always recall the settings used prior to power down Figure 3 Switch and LED locations ...

Страница 13: ...l automatically be written into flash ram and stored see Auto Store The module will function normally with the switch left in the ON position but it is recommended to set it to OFF to prevent accidental changes to the stored module configuration if the switches are moved Dip Switch 2 When set to ON this configures the module for dual 1 2 mode of operation OFF sets single 1 4 mode Note when in 1 4 ...

Страница 14: ... 5 This switch configures the analog output 1 i e what SDI input is used ON selects SDI IN 1 OFF selects SDI IN 2 Dip Switch 6 This switch configures the analog output 2 i e what SDI input is used ON selects SDI IN 2 OFF selects SDI IN 1 Factory Preset Condition The D VD 5002 is delivered programmed and preset for the following mode of operation Switch 1 OFF Local Adjustment Disabled Switch 2 ON D...

Страница 15: ...5002 Version1 1 Page 15 Auto Store If no parameters are changed for 10 seconds then the current settings will be written into flash memory automatically this can be seen by the channel status LEDS flashing yellow four times ...

Страница 16: ...ne for each channel figure 3 Alarm Indicator There is also a single alarm LED on the lower edge of the module figure 3 This is visible through the card frame front cover and provides a general indication of the module status LED OFF indicates power is lost or there is a power supply fault LED Color Indication Green Input Present Red Input Lost LED Color Indication Green Signal Present locked Yello...

Страница 17: ...ional control system and software Once the specific module has been selected on the control system there is a locate button on the top of the GUI Locate Function in Control System When Locate is selected the status indicator on the GUI and the alarm LED will flash yellow in the following continuous sequence 3 short flashes Pause 3 short flashes Use of the locate function will not interfere with th...

Страница 18: ...75 Ohm BNC Output level 1 0 V pp Operating Modes Dual 2 x 1 2 reclocked or non clocked Single 1 x 1 4 reclocked or non clocked Performance Cable Equalization Up to 250m using Belden 8281 270Mbit s Jitter SDI 0 2 UI Control Local settings dip switch Status Monitoring LED Signal presence and PLL lock indication Electrical Specifications Operating Voltage 5VDC Power Consumption 4 5 W Safety IEC 60950...

Страница 19: ...ack controller for the R FR 5010 Card Frame R CT 5010 Rack Bus Extension for the R FR 5010 Card Frame In combination with R CT 5020 Parts List Due to the very dense design and miniature surface mount technology the module is not field serviceable The information for a replacement assembly is below D VD 5002 CardModule complete Description Dual SDI DA w monitoring Model Number D VD 5002 Part Number...

Страница 20: ...istributor for assistance We offer a fixed cost service exchange program for defective Series 5000 CardModules out of Warranty Please contact your distributor or check our web site for details on this program More detailed information and product updates may be available on our web site www lynx technik com You will also find links to contact us directly for assistance ...

Страница 21: ... Technik can be contacted directly using the information below Address LYNX Technik AG Brunnenweg 3 D 64331 Weiterstadt Germany Website www lynx technik com E Mail info lynx technik com LYNX Technik manufactures a complete range of high quality modular products for broadcast and Professional markets please contact your local representative or visit our web site for more product information ...

Страница 22: ...Reference Manual D VD 5002 Version1 1 Page 22 Notes ...

Отзывы: