background image

 

3

 
 
 

1.  IMPORTANT SAFETY INSTRUCTIONS 

 

                                     

                       

 

 

CAUTION: 

  

To reduce the risk of electric shock do not remove cover (or back panel). No user serviceable parts 
inside. Refer servicing to qualified personnel only. 

 

WARNING:

  To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. 

 
                            This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the 

product enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. 

 
 
          

This  symbol  is  intended  to  alert  the  user  of  the  presence  of  important  operating  and  maintenance 
(servicing) instruction in the literature accompanying the appliance. Please carefully read the owner’s 
manual. 

 

INSTRUCTIONS: 

 

All safety and operating instructions should be read before the product is operated. 
 

Retain these instructions: 

All safety and operating instructions should be retained for future reference.  
This owner’s manual should be considered as a part of the product, it must accompany it at all times, and it needs to be 
delivered  to  the  new  user  when  this  product  is  sold.  In  this  way  the  new  owner  will  be  aware  of  all  the  installation, 
operating and safety instructions.  

 

Heed all warnings: 

All warnings on the product and in owner’s manual should be adhered to

.  

Heed all warnings. 

 

Follow all instructions: 

All operating and user’s instructions must be followed. 

 

  Sentences preceded by 

 symbol contain important safety instruction. Please read it carefully. 

 

 

DETAILED SAFETY INSTRUCTIONS. 

 

Water and moisture: 

This apparatus should not be used near water (i.e. bathtub, kitchen sink, swimming pools, etc.) 

 

Ventilation

This apparatus should be placed in a position that doesn’t interfere with its correct ventilation. This unit, for example, 
should not be placed on a bed, sofa cover  o similar surfaces that could cover  ventilation openings, or placed in a 
built-in installation, such a bookcase or a cabinet that could block air flow trough ventilation openings. 

 

Heat:  

This apparatus should be placed away from sources of heat, like radiators, heat registers, stoves or other products 
(including amplifiers) that produce heat. 

 

Power sources: 

 

This apparatus should only be connected to a power source of type specified in this owner’s manual or on the 
unit. 

 

If the supplied AC power cable plug is different from wall socket, please contact an electrician to change the AC 
power plug. 

 

 

Grounding or Polarization: 

 

All precautions must be observed in order to avoid defeating grounding or polarization. 

 

Unit metal parts are grounded through the AC power cord.  

 

If the AC power outlet doesn’t have grounding, consult an electrician for outlet grounding. 

 

Содержание H-7000

Страница 1: ...INSTRUCTION MANUAL Digital Conference System H 7000 H 8310c H 8310d H EX08 ...

Страница 2: ...FUNCTIONS AND CONTROLS H 7000 6 5 PRESIDENT H 8310c AND DELEGATE H 8310d UNIT FUNCTIONS AND CONTROLS 7 6 CONNECTION 8 7 HOW TO USE THE SYSTEM 11 8 FRONT PANEL FUNCTIONS AND CONTROLS H 08EX 11 9 REAR PANEL FUNCTIONS AND CONTROLS H 08EX 111 10 EXPANSION UNIT CONNECTION 12 11 PACKAGE CONTENTS 144 12 TECHNICAL FEATURES 14 ...

Страница 3: ...gs on the product and in owner s manual should be adhered to Heed all warnings Follow all instructions All operating and user s instructions must be followed Sentences preceded by symbol contain important safety instruction Please read it carefully DETAILED SAFETY INSTRUCTIONS Water and moisture This apparatus should not be used near water i e bathtub kitchen sink swimming pools etc Ventilation Th...

Страница 4: ...ized service center or skilled personnel When the unit works improperly or it doesn t work at all If power cord or plug is damaged If liquid has spilled or objects have fallen into the unit The unit has been exposed to rain The unit doesn t operate normally or exhibits a marked change in performance If the product has been dropped or has been damaged in any way Maintenance The user shouldn t attem...

Страница 5: ... unit can support up to 60 stations divided on six lines never use more than 30 stations on each line Adding four expansion units the system can control up to 254 stations The serial connection of each station is achieved through single multicore prerouted cables that may be used either for fixed or mobile systems Main Functions It directly powers and controls 64 microphone stations President stat...

Страница 6: ...H 7000 fig 2 1 TREBLE GAIN Rotate this control counterclockwise to emphasize high frequencies 2 AUX IN Line level input RCA Connect this input to an audio source such as a CD player etc 3 MASTER OUT REG LINE Recording output RCA To record a conference connect a recorder to this output Unbalanced line level output 4 BAL OUT Balanced signal output male XLR3 Connect mixer or amplifier to this output ...

Страница 7: ...mm jack lavalier MIC jack of prisident unit 4 Vol knob When using the knob you can decrease or increase speaker monitor volume 5 MIC ON OFF Press this button to speak the station will be immediately enabled unless the limit of simultaneously enabled stations has been reached Press again to turn off microphone 6 PRIORITY Press this button on the PRESIDENT station to disable all other speaker statio...

Страница 8: ...o each line and no more than 64 stations altogether Closed loop lines can be created with the optional 3 m cable as shown in figure 6 In this way no station will be isolated in case of interruption one of the lines The configuration shown in figure 6 cannot allow more than 30 stations on each loop In any case the maximum limit of 64 stations cannot be exceeded The system can host more than one PRE...

Страница 9: ...9 fig 6 ...

Страница 10: ...TIONS Balanced connection Unbalanced connection Balanced connection with TRS jack Unbalanced connection with TRS jack Balanced connection on EUROBLOC connector Unbalanced connection on EUROBLOC connector RCA Connection ...

Страница 11: ...alls below this limit There are 4 options for limit number 1 2 3 5 8 FRONT PANEL FUNCTIONS AND CONTROLS H 08EX fig 7 1 POWER Main power switch 9 REAR PANEL FUNCTIONS AND CONTROLS H 08EX fig 8 1 MAINS POWER INPUT Connect main unit to 230 V AC 50 60 Hz mains 8 A fuse socket 2 EXPANDER OUTPUT 6 inputs for President Delegate units Each line can be connected to up to 30 stations do not connect more tha...

Страница 12: ...imit to the number of expansion units that can be connected yet the total number of manageable microphone stations must not exceed 254 10 EXPANSION UNIT CONNECTION Method 1 fig 9 Note Be sure to keep the shortest possible distance between the central unit and the last microphone For long distances we advise opting for method 1 ...

Страница 13: ...13 Method 2 fig 10 ...

Страница 14: ...T H D 0 05 0 05 0 05 Speaker 2X50W RMS 4 16 Ohm Dimensions WxHxD 482x90x353 mm 2U standard 19 rack 482x90x353 mm 2U standard 19 rack Base 205x55x150 Gooseneck 390 mm Weight 16 34 kg 14 kg 1 77 kg Power Consumption 500 W 450 W 2 W Power supply 230 V AC 50 60 Hz 230 V AC 50 60 Hz 24 V DC by 8 PIN cable This product complies with Directive 89 336 EEC Electromagnetic Compatibility and later changes 92...

Отзывы: