background image

 

5

 
Thank  you  for  choosing  our  product  and  for  trusting  our  brand,  which  strives  to  be  synonymous  with 
professionalism,  precision,  high  quality  and  reliability.  All  of  our  products  comply  with  EC  regulations 
regarding audio equipment for continuous use. 
 

2.  DESCRIPTION 

 
This conference system uses digital technologies according to the European Community's IEC914 and ISO 
standards. 
It is composed of a main unit – H-7000 – and two microphone units – Delegate (H-8310d) and President (H-
8310c)  –  that  feature  high  sensitivity,  a  wide  frequency  response,  an  internal  loudspeaker  and  a  cardioid 
electret microphone  with  a lighted  ring for  the visual identification  of  the microphone  in  use. The  system is 
precabled to ensure fast and easy installation. 
The  device  may  include  up  to  64  microphone  stations,  daisy-chained  on  four  independent  lines  (or  a 
maximum of 30 stations on each line). 
The system involves the use of several expansion units – H-08EX. Every expansion unit can support up to 
60 stations divided on six lines (never use more than 30 stations on each line). 
Adding four expansion units, the system can control up to 254 stations.  
 
The  serial  connection  of  each  station  is  achieved  through  single  multicore,  prerouted  cables  that  may  be 
used either for fixed or mobile systems.   
 
Main Functions:  
 

 

It directly powers and controls 64 microphone stations. 

 

President station has priority on others.  

 

Three operating modes: FREE MODE, LIMIT 1/2/3/5 

 

One microphone input (MIC) and one line input (LINE) for external units. 

 

TAPE output for recordings and line output (LINE) for amplification (balanced and unbalanced). 

 

It allows insertion of an audio processor to the chain. 

 

Microphone sensitivity level control. 

 

Loudspeaker level control for the unit monitors

 

 

Built-in power amplifier, which can support external speaker and control the volume directly 

 

 

 

 

Product complies with 

CE 

regulations 

 

 

3.  FRONT PANEL FUNCTIONS AND CONTROLS – H-7000 
 

 

fig.1 

1. POWER 

Main power switch 

 

2. BASS 

Sets the bass level of external speaker

 

 

3. TREBLE 

Sets the treble level of external speaker

 

 

4. VOL 

Sets the system amplifier audio level of external speaker

 

Содержание H-7000

Страница 1: ...INSTRUCTION MANUAL Digital Conference System H 7000 H 8310c H 8310d H EX08 ...

Страница 2: ...FUNCTIONS AND CONTROLS H 7000 6 5 PRESIDENT H 8310c AND DELEGATE H 8310d UNIT FUNCTIONS AND CONTROLS 7 6 CONNECTION 8 7 HOW TO USE THE SYSTEM 11 8 FRONT PANEL FUNCTIONS AND CONTROLS H 08EX 11 9 REAR PANEL FUNCTIONS AND CONTROLS H 08EX 111 10 EXPANSION UNIT CONNECTION 12 11 PACKAGE CONTENTS 144 12 TECHNICAL FEATURES 14 ...

Страница 3: ...gs on the product and in owner s manual should be adhered to Heed all warnings Follow all instructions All operating and user s instructions must be followed Sentences preceded by symbol contain important safety instruction Please read it carefully DETAILED SAFETY INSTRUCTIONS Water and moisture This apparatus should not be used near water i e bathtub kitchen sink swimming pools etc Ventilation Th...

Страница 4: ...ized service center or skilled personnel When the unit works improperly or it doesn t work at all If power cord or plug is damaged If liquid has spilled or objects have fallen into the unit The unit has been exposed to rain The unit doesn t operate normally or exhibits a marked change in performance If the product has been dropped or has been damaged in any way Maintenance The user shouldn t attem...

Страница 5: ... unit can support up to 60 stations divided on six lines never use more than 30 stations on each line Adding four expansion units the system can control up to 254 stations The serial connection of each station is achieved through single multicore prerouted cables that may be used either for fixed or mobile systems Main Functions It directly powers and controls 64 microphone stations President stat...

Страница 6: ...H 7000 fig 2 1 TREBLE GAIN Rotate this control counterclockwise to emphasize high frequencies 2 AUX IN Line level input RCA Connect this input to an audio source such as a CD player etc 3 MASTER OUT REG LINE Recording output RCA To record a conference connect a recorder to this output Unbalanced line level output 4 BAL OUT Balanced signal output male XLR3 Connect mixer or amplifier to this output ...

Страница 7: ...mm jack lavalier MIC jack of prisident unit 4 Vol knob When using the knob you can decrease or increase speaker monitor volume 5 MIC ON OFF Press this button to speak the station will be immediately enabled unless the limit of simultaneously enabled stations has been reached Press again to turn off microphone 6 PRIORITY Press this button on the PRESIDENT station to disable all other speaker statio...

Страница 8: ...o each line and no more than 64 stations altogether Closed loop lines can be created with the optional 3 m cable as shown in figure 6 In this way no station will be isolated in case of interruption one of the lines The configuration shown in figure 6 cannot allow more than 30 stations on each loop In any case the maximum limit of 64 stations cannot be exceeded The system can host more than one PRE...

Страница 9: ...9 fig 6 ...

Страница 10: ...TIONS Balanced connection Unbalanced connection Balanced connection with TRS jack Unbalanced connection with TRS jack Balanced connection on EUROBLOC connector Unbalanced connection on EUROBLOC connector RCA Connection ...

Страница 11: ...alls below this limit There are 4 options for limit number 1 2 3 5 8 FRONT PANEL FUNCTIONS AND CONTROLS H 08EX fig 7 1 POWER Main power switch 9 REAR PANEL FUNCTIONS AND CONTROLS H 08EX fig 8 1 MAINS POWER INPUT Connect main unit to 230 V AC 50 60 Hz mains 8 A fuse socket 2 EXPANDER OUTPUT 6 inputs for President Delegate units Each line can be connected to up to 30 stations do not connect more tha...

Страница 12: ...imit to the number of expansion units that can be connected yet the total number of manageable microphone stations must not exceed 254 10 EXPANSION UNIT CONNECTION Method 1 fig 9 Note Be sure to keep the shortest possible distance between the central unit and the last microphone For long distances we advise opting for method 1 ...

Страница 13: ...13 Method 2 fig 10 ...

Страница 14: ...T H D 0 05 0 05 0 05 Speaker 2X50W RMS 4 16 Ohm Dimensions WxHxD 482x90x353 mm 2U standard 19 rack 482x90x353 mm 2U standard 19 rack Base 205x55x150 Gooseneck 390 mm Weight 16 34 kg 14 kg 1 77 kg Power Consumption 500 W 450 W 2 W Power supply 230 V AC 50 60 Hz 230 V AC 50 60 Hz 24 V DC by 8 PIN cable This product complies with Directive 89 336 EEC Electromagnetic Compatibility and later changes 92...

Отзывы: